Bacterial Endotoxins
					Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
					
				 
								- 
				    
					
Bacterial Retention
					Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
					
				 
								- 
				    
					
Cartridge Code
					Not Applicable
					
				 
								- 
				    
					
Catalogue Number
					MCGL10S03
					
				 
								- 
				    
					
Chemistry
					Polyvinylidene Fluoride (PVDF)
					
				 
								- 
				    
					
Device Configuration
					Cartridge
					
				 
								- 
				    
					
Device Material
					Polysulfone
					
				 
								- 
				    
					
Filtration Area
					500 cm²
					
				 
								- 
				    
					
Flow Rate
					15 L/min @ 3.5 bar ΔP
					
				 
								- 
				    
					
Good Manufacturing Practices
					These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
					
				 
								- 
				    
					
Gravimetric Extractables
					The extractables level was equal to or less than 2.5 mg per sterilized device after 24 hours in water at controlled room temperature.
					
				 
								- 
				    
					
Material Package
					Double Easy-Open bag
					
				 
								- 
				    
					
Material Size
					3
					
				 
								- 
				    
					
Maximum Differential Pressure, bar (psid)
					Forward: 4.1 bar (60 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 123 °C; Reverse: 0.7 bar (10 psid) @ 25 °C
					
				 
								- 
				    
					
Maximum Inlet Pressure, bar (psi)
					Forward - 4.1 bar (60 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 123 °C; Reverse - 0.7 bar (10 psi) @ 25 °C
					
				 
								- 
				    
					
Media
					Durapore®
					
				 
								- 
				    
					
Non-Fiber Releasing
					This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
					
				 
								- 
				    
					
Oxidizable Substances
					Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥200 mL
					
				 
								- 
				    
					
Pore Size
					0.22 µm
					
				 
								- 
				    
					
Seal Material
					Silicone (SI)
					
				 
								- 
				    
					
Sterility
					Other
					
				 
								- 
				    
					
Sterilization
					5 SIP cycles of 60 min @ 135 °C; 5 autoclave cycles of 60 min @ 126 °C
					
				 
								- 
				    
					
Support Material
					Polysulfone
					
				 
								- 
				    
					
Trade Name
					Millidisk®
					
				 
								- 
				    
					
USP Bacterial Endotoxins
					A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
					
				 
								- 
				    
					
Wettability
					Hydrophilic