About 30 years ago MACHEREY‑NAGEL designed and introduced CHROMABOND SPE cartridges containing silica-based adsorbents.

SPE is a form of digital (step-wise) chromatography designed to extract, partition, and / or adsorb one or more components from a liquid phase (sample) onto a stationary phase (adsorbent or resin). An adsorbed substance can be removed from the adsorbent by stepwise increase of elution strength of the eluent (step gradient technique).

SPE extends a chromatographic system’s lifetime, improves qualitative and quantitative analysis, and the demand placed on an analytical instrument is considerably lessened.


Catalog No. Product Net Price
MN815610.5 LC packing material (adsorbents, bulk), Polyamide, > 0.07 mm Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • LC, packing material (adsorbent, bulk)
  • Phase
  • Polyamide
  • Mode
  • Normal phase (NP)
  • Base material
  • Polyamide
  • Surface chemistry
  • Polyamide (PA)
  • Endcapped
  • No
  • Selling unit
  • 1 kg, 5 kg
  • Recommended application(s)
  • LC packing material
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • > 0.07 mm
  • Particle shape
  • Irregular
  • Storage temperature
  • RT
MN815620.5 LC packing material (adsorbents, bulk), Polyamide, 0.05–0.16 mm Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • LC, packing material (adsorbent, bulk)
  • Phase
  • Polyamide
  • Mode
  • Normal phase (NP)
  • Base material
  • Polyamide
  • Surface chemistry
  • Polyamide (PA)
  • Endcapped
  • No
  • Selling unit
  • 1 kg, 5 kg
  • Recommended application(s)
  • LC packing material
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 0.05–0.16 mm
  • Particle shape
  • Irregular
  • Storage temperature
  • RT
MN730007 SPE columns, CHROMABOND PA, 40–80 µm, 6 mL/500 mg Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMABOND
  • Phase
  • PA
  • Mode
  • Normal phase (NP)
  • Base material
  • Polyamide
  • Surface chemistry
  • Polyamide (PA)
  • Column type
  • SPE column
  • Hardware
  • Polypropylene (PP) columns with polyethylene (PE) filter elements
  • Column shape
  • Open tubular syringe-shaped column with Luer tip outlet
  • Column volume
  • 6 mL
  • Filling quantity
  • 500 mg
  • Column volume/adsorbent weight
  • 6 mL/500 mg
  • Recommended application(s)
  • Flavonoids, PAH
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 40–80 µm
  • Particle shape
  • Irregular
  • pH stability
  • Not available or not applicable
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN730126 SPE columns, CHROMABOND PA, 40–80 µm, 3 mL/500 mg Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMABOND
  • Phase
  • PA
  • Mode
  • Normal phase (NP)
  • Base material
  • Polyamide
  • Surface chemistry
  • Polyamide (PA)
  • Column type
  • SPE column
  • Hardware
  • Polypropylene (PP) columns with polyethylene (PE) filter elements
  • Column shape
  • Open tubular syringe-shaped column with Luer tip outlet
  • Column volume
  • 3 mL
  • Filling quantity
  • 500 mg
  • Column volume/adsorbent weight
  • 3 mL/500 mg
  • Recommended application(s)
  • Flavonoids, PAH
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 40–80 µm
  • Particle shape
  • Irregular
  • pH stability
  • Not available or not applicable
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN730127 SPE columns, CHROMABOND PA, 40–80 µm, 6 mL/1000 mg Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMABOND
  • Phase
  • PA
  • Mode
  • Normal phase (NP)
  • Base material
  • Polyamide
  • Surface chemistry
  • Polyamide (PA)
  • Column type
  • SPE column
  • Hardware
  • Polypropylene (PP) columns with polyethylene (PE) filter elements
  • Column shape
  • Open tubular syringe-shaped column with Luer tip outlet
  • Column volume
  • 6 mL
  • Filling quantity
  • 1000 mg
  • Column volume/adsorbent weight
  • 6 mL/1000 mg
  • Recommended application(s)
  • Flavonoids, PAH
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 40–80 µm
  • Particle shape
  • Irregular
  • pH stability
  • Not available or not applicable
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN730026 Polyethylene filter elements for CHROMABOND SPE PP empty columns, 70 mL Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE), accessory
  • Brand
  • CHROMABOND
  • Hardware
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN730034 Polyethylene filter elements for CHROMABOND SPE PP empty columns, 30 mL Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE), accessory
  • Brand
  • CHROMABOND
  • Hardware
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN731804 SPE cartridges, CHROMAFIX C18 ec, Small Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMAFIX
  • Phase
  • C18 ec
  • Mode
  • Reversed phase (RP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Octadecyl (ODS, C18 ec, RP18 ec) modified silica phase, endcapped
  • Column type
  • SPE cartridge
  • Hardware
  • Polypropylene (PP) cartridges with polyethylene (PE) filter elements
  • Column shape
  • Tubular syringe-shaped cartridge with Luer tip inlet and outlet
  • Filling quantity
  • 90 mg
  • Recommended application(s)
  • Aflatoxins, Amphetamines, Antibiotics, Antiepileptics, Barbiturates, Caffeine, Drugs, Fatty acids, Heavy metals, Nicotine, Nonpolar samples, PAH, PCBs, Pesticides, Preservatives, Very well suited for desalting of samples, Vitamins
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 45 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • pH stability
  • 2.0–8.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN731805 SPE cartridges, CHROMAFIX C18 ec, Medium Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMAFIX
  • Phase
  • C18 ec
  • Mode
  • Reversed phase (RP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Octadecyl (ODS, C18 ec, RP18 ec) modified silica phase, endcapped
  • Column type
  • SPE cartridge
  • Hardware
  • Polypropylene (PP) cartridges with polyethylene (PE) filter elements
  • Column shape
  • Tubular syringe-shaped cartridge with Luer tip inlet and outlet
  • Filling quantity
  • 320 mg
  • Recommended application(s)
  • Aflatoxins, Amphetamines, Antibiotics, Antiepileptics, Barbiturates, Caffeine, Drugs, Fatty acids, Heavy metals, Nicotine, Nonpolar samples, PAH, PCBs, Pesticides, Preservatives, Very well suited for desalting of samples, Vitamins
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 45 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • pH stability
  • 2.0–8.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN731806 SPE cartridges, CHROMAFIX C18 ec, Large Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMAFIX
  • Phase
  • C18 ec
  • Mode
  • Reversed phase (RP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Octadecyl (ODS, C18 ec, RP18 ec) modified silica phase, endcapped
  • Column type
  • SPE cartridge
  • Hardware
  • Polypropylene (PP) cartridges with polyethylene (PE) filter elements
  • Column shape
  • Tubular syringe-shaped cartridge with Luer tip inlet and outlet
  • Filling quantity
  • 630 mg
  • Recommended application(s)
  • Aflatoxins, Amphetamines, Antibiotics, Antiepileptics, Barbiturates, Caffeine, Drugs, Fatty acids, Heavy metals, Nicotine, Nonpolar samples, PAH, PCBs, Pesticides, Preservatives, Very well suited for desalting of samples, Vitamins
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 45 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • pH stability
  • 2.0–8.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT

Overview

Main steps of the SPE procedure

1) Conditioning

Conditioning of the adsorbent is necessary in order to ensure reproducible interaction with the analyte. Conditioning, also called solvation, results in a wetting of the adsorbent and thus produces an environment, which is suitable for adsorption of the analyte. Nonpolar adsorbents are usually conditioned with 2–3 column volumes of a solvent, which is miscible with water (methanol, THF, 2-propanol etc.), followed by the solvent in which the analyte is dissolved (pure matrix, e.g., water, buffer). Polar adsorbents are conditioned with nonpolar solvents. After the conditioning step the adsorbent bed must not run dry, because otherwise solvation is destroyed (deconditioning).


2) Sample application (adsorption)

Sample application can be performed with positive or negative pressure with a flow rate of ~3 mL/min. Sample volumes vary from a few mL up to liters.


3) Washing

Washing of the adsorbent is usually achieved with a special wash solution; however, in some cases it may not be necessary. If the polarity difference between wash solution and eluent is very large, or if both are not miscible, drying of the adsorbent bed after washing is recommended to improve elution and recovery.


4) Elution

Elution with a suitable eluent should not be too fast. The elution speed depends on the column or cartridge dimension and the quantity of adsorbent (about 1 mL/min).


Since analytes can either be adsorbed on the SPE packing material or directly flown through while the interfering substances are retained, two general separation procedures are possible – both cases are shown in the figure below.



Resources