P2C300C25
Pellicon® 2 Maxi Cassette with Ultracel® 300 kDa Membrane, C screen, 2.5 m²
9199
Add to Cart
Catalogue Number
P2C300C25
Chemistry
Composite Regenerated Cellulose (CRC)
Device Configuration
Maxi Cassette
Device Material
Polypropylene
Filter Code
PLCMK
Filter Type
Ultrafiltration
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1500 mg/m² after a water flush.
Height
7.6 cm (3 in.)
Key Applications
Protein PurificationAnalytical Sample Prep
Length
20.6 cm (8.1 in)
Material Size
1
Maximum Operating Temperature
0 - 30°C
Maximum Transmembrane Pressure
Forward: 3.4 bar (50 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
Media
Ultracel®
Membrane Area
2.5 m²
NMWL
300 kDa
pH Range
pH2 – pH13
Recirculation Rate
4 to 7 L/min/m²
Screen Material
Polypropylene (PP)
Screen Type
Type C screen (coarse screen)
Trade Name
Pellicon®
Width
17.8 cm (7.0 in.)
P2C300C25
Pellicon® 2 Maxi Cassette with Ultracel® 300 kDa Membrane, C screen, 2.5 m²
9199
Add to Cart
Catalogue Number
P2C300C25
Chemistry
Composite Regenerated Cellulose (CRC)
Device Configuration
Maxi Cassette
Device Material
Polypropylene
Filter Code
PLCMK
Filter Type
Ultrafiltration
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1500 mg/m² after a water flush.
Height
7.6 cm (3 in.)
Key Applications
Protein PurificationAnalytical Sample Prep
Length
20.6 cm (8.1 in)
Material Size
1
Maximum Operating Temperature
0 - 30°C
Maximum Transmembrane Pressure
Forward: 3.4 bar (50 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
Media
Ultracel®
Membrane Area
2.5 m²
NMWL
300 kDa
pH Range
pH2 – pH13
Recirculation Rate
4 to 7 L/min/m²
Screen Material
Polypropylene (PP)
Screen Type
Type C screen (coarse screen)
Trade Name
Pellicon®
Width
17.8 cm (7.0 in.)
P2B005A25
Pellicon® 2 Maxi Cassette with Biomax® 5 kDa Membrane, A screen, 2.5 m²
9337
Add to Cart
Catalogue Number
P2B005A25
Chemistry
Polyethersulfone (PES)
Device Configuration
Maxi Cassette
Device Material
Polypropylene
Filter Code
Biomax 5
Filter Type
Ultrafiltration
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1500 mg/m² after a water flush.
Height
7.6 cm (3 in.)
Key Applications
Protein PurificationAnalytical Sample Prep
Length
20.6 cm (8.1 in)
Material Size
1
Maximum Operating Temperature
0 - 50°C
Maximum Transmembrane Pressure
Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
Media
Biomax®
Membrane Area
2.5 m²
NMWL
5 kDa
pH Range
pH1 – pH14
Recirculation Rate
4 to 7 L/min/m²
Screen Material
Polypropylene (PP)
Screen Type
Type A screen (tight screen)
Trade Name
Pellicon®
Width
17.8 cm (7.0 in.)
P2B005A25
Pellicon® 2 Maxi Cassette with Biomax® 5 kDa Membrane, A screen, 2.5 m²
9337
Add to Cart
Catalogue Number
P2B005A25
Chemistry
Polyethersulfone (PES)
Device Configuration
Maxi Cassette
Device Material
Polypropylene
Filter Code
Biomax 5
Filter Type
Ultrafiltration
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1500 mg/m² after a water flush.
Height
7.6 cm (3 in.)
Key Applications
Protein PurificationAnalytical Sample Prep
Length
20.6 cm (8.1 in)
Material Size
1
Maximum Operating Temperature
0 - 50°C
Maximum Transmembrane Pressure
Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
Media
Biomax®
Membrane Area
2.5 m²
NMWL
5 kDa
pH Range
pH1 – pH14
Recirculation Rate
4 to 7 L/min/m²
Screen Material
Polypropylene (PP)
Screen Type
Type A screen (tight screen)
Trade Name
Pellicon®
Width
17.8 cm (7.0 in.)
P2B008A25
Pellicon® 2 Maxi Cassette with Biomax® 8 kDa Membrane, A screen, 2.5 m²
9337
Add to Cart
Catalogue Number
P2B008A25
Chemistry
Polyethersulfone (PES)
Device Configuration
Maxi Cassette
Device Material
Polypropylene
Filter Code
Biomax 8
Filter Type
Ultrafiltration
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1500 mg/m² after a water flush.
Height
7.6 cm (3 in.)
Key Applications
Protein PurificationAnalytical Sample Prep
Length
20.6 cm (8.1 in)
Material Size
1
Maximum Operating Temperature
0 - 50°C
Maximum Transmembrane Pressure
Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
Media
Biomax®
Membrane Area
2.5 m²
NMWL
8 kDa
pH Range
pH1 – pH14
Recirculation Rate
4 to 7 L/min/m²
Screen Material
Polypropylene (PP)
Screen Type
Type A screen (tight screen)
Trade Name
Pellicon®
Width
17.8 cm (7.0 in.)
P2B008A25
Pellicon® 2 Maxi Cassette with Biomax® 8 kDa Membrane, A screen, 2.5 m²
9337
Add to Cart
Catalogue Number
P2B008A25
Chemistry
Polyethersulfone (PES)
Device Configuration
Maxi Cassette
Device Material
Polypropylene
Filter Code
Biomax 8
Filter Type
Ultrafiltration
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1500 mg/m² after a water flush.
Height
7.6 cm (3 in.)
Key Applications
Protein PurificationAnalytical Sample Prep
Length
20.6 cm (8.1 in)
Material Size
1
Maximum Operating Temperature
0 - 50°C
Maximum Transmembrane Pressure
Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
Media
Biomax®
Membrane Area
2.5 m²
NMWL
8 kDa
pH Range
pH1 – pH14
Recirculation Rate
4 to 7 L/min/m²
Screen Material
Polypropylene (PP)
Screen Type
Type A screen (tight screen)
Trade Name
Pellicon®
Width
17.8 cm (7.0 in.)
P2B050C25
Pellicon® 2 Maxi Cassette with Biomax® 50 kDa Membrane, C screen, 2.5 m²
9513
Add to Cart
Catalogue Number
P2B050C25
Chemistry
Polyethersulfone (PES)
Device Configuration
Maxi Cassette
Device Material
Polypropylene
Filter Code
Biomax 50
Filter Type
Ultrafiltration
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1500 mg/m² after a water flush.
Height
7.6 cm (3 in.)
Key Applications
Protein PurificationAnalytical Sample Prep
Length
20.6 cm (8.1 in)
Material Size
1
Maximum Operating Temperature
0 - 50°C
Maximum Transmembrane Pressure
Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
Media
Biomax®
Membrane Area
2.5 m²
NMWL
50 kDa
pH Range
pH1 – pH14
Recirculation Rate
4 to 7 L/min/m²
Screen Material
Polypropylene (PP)
Screen Type
Type C screen (coarse screen)
Trade Name
Pellicon®
Width
17.8 cm (7.0 in.)
P2B050C25
Pellicon® 2 Maxi Cassette with Biomax® 50 kDa Membrane, C screen, 2.5 m²
9513
Add to Cart
Catalogue Number
P2B050C25
Chemistry
Polyethersulfone (PES)
Device Configuration
Maxi Cassette
Device Material
Polypropylene
Filter Code
Biomax 50
Filter Type
Ultrafiltration
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1500 mg/m² after a water flush.
Height
7.6 cm (3 in.)
Key Applications
Protein PurificationAnalytical Sample Prep
Length
20.6 cm (8.1 in)
Material Size
1
Maximum Operating Temperature
0 - 50°C
Maximum Transmembrane Pressure
Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
Media
Biomax®
Membrane Area
2.5 m²
NMWL
50 kDa
pH Range
pH1 – pH14
Recirculation Rate
4 to 7 L/min/m²
Screen Material
Polypropylene (PP)
Screen Type
Type C screen (coarse screen)
Trade Name
Pellicon®
Width
17.8 cm (7.0 in.)
SK1M018W01
Pellicon® 2 Maxi Cassette with Biomax® 10 kDa Membrane, C screen, 2.5 m²
9611
Add to Cart
Catalogue Number
SK1M018W01
Chemistry
Polyethersulfone (PES)
Device Configuration
Maxi Cassette
Device Material
Polypropylene
Filter Code
Biomax 10
Filter Type
Ultrafiltration
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1500 mg/m² after a water flush.
Key Applications
Protein PurificationAnalytical Sample Prep
Length
20.6 cm (8.1 in)
Material Size
1
Maximum Operating Temperature
0 - 50°C
Maximum Transmembrane Pressure
Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
Media
Biomax®
Membrane Area
2.5 m²
NMWL
10 kDa
pH Range
pH1 – pH14
Recirculation Rate
4 to 7 L/min/m²
Screen Material
Polypropylene (PP)
Screen Type
Type C screen (coarse screen)
Trade Name
Pellicon®
Width
17.8 cm (7.0 in.)
SK1M019W01
Pellicon® 2 Maxi Cassette with Biomax® 30 kDa Membrane, C screen, 2.5 m²
9611
Add to Cart
Catalogue Number
SK1M019W01
Chemistry
Polyethersulfone (PES)
Device Configuration
Maxi Cassette
Device Material
Polypropylene
Filter Code
Biomax 30
Filter Type
Ultrafiltration
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1500 mg/m² after a water flush.
Key Applications
Protein PurificationAnalytical Sample Prep
Length
20.6 cm (8.1 in)
Material Size
1
Maximum Operating Temperature
0 - 50°C
Maximum Transmembrane Pressure
Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
Media
Biomax®
Membrane Area
2.5 m²
NMWL
30 kDa
pH Range
pH1 – pH14
Recirculation Rate
4 to 7 L/min/m²
Screen Material
Polypropylene (PP)
Screen Type
Type C screen (coarse screen)
Trade Name
Pellicon®
Width
17.8 cm (7.0 in.)