+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
SN3HA47FF3 Optiscale® Capsule Polygard®-CN 30 µm 3/4 in. TC/TC 89 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Catalogue Number
  • SN3HA47FF3
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Capsule
  • Device Material
  • Polycarbonate
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 17.7 cm²
  • Format
  • Single Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 3/4 in.
  • Material Size
  • 3
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 25 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Polygard®-CN
  • Nominal Pore Size
  • 30.0 µm
  • Outlet Connection
  • Sanitary Flange
  • Outlet Connection Diameter
  • 3/4 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥100 mL
  • Pore Size
  • 30.0 µm
  • Seal Material
  • Fluoroelastomer (FKM)
  • Sterilization
  • 3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
  • Support Material
  • Polypropylene
  • Trade Name
  • OptiScale®
  • Vent Cap Material
  • Polyvinylidene fluoride (PVDF)
SN3HA47FF3 Optiscale® Capsule Polygard®-CN 30 µm 3/4 in. TC/TC 89 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Catalogue Number
  • SN3HA47FF3
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Capsule
  • Device Material
  • Polycarbonate
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 17.7 cm²
  • Format
  • Single Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 3/4 in.
  • Material Size
  • 3
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 25 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Polygard®-CN
  • Nominal Pore Size
  • 30.0 µm
  • Outlet Connection
  • Sanitary Flange
  • Outlet Connection Diameter
  • 3/4 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥100 mL
  • Pore Size
  • 30.0 µm
  • Seal Material
  • Fluoroelastomer (FKM)
  • Sterilization
  • 3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
  • Support Material
  • Polypropylene
  • Trade Name
  • OptiScale®
  • Vent Cap Material
  • Polyvinylidene fluoride (PVDF)
SN50A47FH3 Optiscale® Capsule Polygard®-CN 5.0 µm 3/4 in. TC-1/4 in. HB 89 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Catalogue Number
  • SN50A47FH3
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Capsule
  • Device Material
  • Polycarbonate
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 17.7 cm²
  • Format
  • Single Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 3/4 in.
  • Material Size
  • 3
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 25 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Polygard®-CN
  • Nominal Pore Size
  • 5.0 µm
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 1/4 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥100 mL
  • Pore Size
  • 5.0 µm
  • Seal Material
  • Fluoroelastomer (FKM)
  • Sterilization
  • 3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
  • Support Material
  • Polypropylene
  • Trade Name
  • OptiScale®
  • Vent Cap Material
  • Polyvinylidene fluoride (PVDF)
SN50A47FH3 Optiscale® Capsule Polygard®-CN 5.0 µm 3/4 in. TC-1/4 in. HB 89 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Catalogue Number
  • SN50A47FH3
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Capsule
  • Device Material
  • Polycarbonate
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 17.7 cm²
  • Format
  • Single Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 3/4 in.
  • Material Size
  • 3
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 25 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Polygard®-CN
  • Nominal Pore Size
  • 5.0 µm
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 1/4 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥100 mL
  • Pore Size
  • 5.0 µm
  • Seal Material
  • Fluoroelastomer (FKM)
  • Sterilization
  • 3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
  • Support Material
  • Polypropylene
  • Trade Name
  • OptiScale®
  • Vent Cap Material
  • Polyvinylidene fluoride (PVDF)
SN50A47HH3 Optiscale® Capsule Polygard®-CN 5.0 µm1/4 in. HB/HB 89 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Catalogue Number
  • SN50A47HH3
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Capsule
  • Device Material
  • Polycarbonate
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 17.7 cm²
  • Format
  • Single Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Hose Barb
  • Inlet Connection Diameter
  • 1/4 in.
  • Material Size
  • 3
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 25 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Polygard®-CN
  • Nominal Pore Size
  • 5.0 µm
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 1/4 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥100 mL
  • Pore Size
  • 5.0 µm
  • Seal Material
  • Fluoroelastomer (FKM)
  • Sterilization
  • 3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
  • Support Material
  • Polypropylene
  • Trade Name
  • OptiScale®
  • Vent Cap Material
  • Polyvinylidene fluoride (PVDF)
SN50A47HH3 Optiscale® Capsule Polygard®-CN 5.0 µm1/4 in. HB/HB 89 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Catalogue Number
  • SN50A47HH3
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Capsule
  • Device Material
  • Polycarbonate
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 17.7 cm²
  • Format
  • Single Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Hose Barb
  • Inlet Connection Diameter
  • 1/4 in.
  • Material Size
  • 3
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 25 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Polygard®-CN
  • Nominal Pore Size
  • 5.0 µm
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 1/4 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥100 mL
  • Pore Size
  • 5.0 µm
  • Seal Material
  • Fluoroelastomer (FKM)
  • Sterilization
  • 3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
  • Support Material
  • Polypropylene
  • Trade Name
  • OptiScale®
  • Vent Cap Material
  • Polyvinylidene fluoride (PVDF)
MK6976 Vessel Cover, cam lock 90 
Add to Cart
  • Catalogue Number
  • 6976
  • Material Size
  • 1
MK6976 Vessel Cover, cam lock 90 
Add to Cart
  • Catalogue Number
  • 6976
  • Material Size
  • 1
D01001S01 Clarigard Cartridge Filter 10 in. 1.0 µm Code 0 Silicone 90 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • D01001S01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤10 mg after 24-h soak in water
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 1.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L
  • Pore Size
  • 1.0 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic
D01001S01 Clarigard Cartridge Filter 10 in. 1.0 µm Code 0 Silicone 90 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • D01001S01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤10 mg after 24-h soak in water
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 1.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L
  • Pore Size
  • 1.0 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources