MCE3523CL3
Millistak+® Depth Filter in µPod® format, CE35 media series, 23 cm2 surface area, Luer fitting connection
134
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
MCE3523CL3
Chemistry
Cellulose (CL)
Device Configuration
µPod
Device Material
Glass fiber reinforced polypropylene
Filter Grade
CE35
Filtration Area
0.0023 m²
Gravimetric Extractables
Not Tested
Height
6.6 cm (2.6 in.)
Length
8.9 cm (3.5 in.)
Material Size
3
Maximum Differential Pressure, bar (psid)
Forward: 2.1 bar (30 psid) @ 40 °C. Reverse: 1.0 bar (15 psid) @ 40 °C
Sterilization
2 autoclave cycles of 60 minutes at 123 °C.
Trade Name
Millistak+®
Wettability
Hydrophilic
MCE3523CL3
Millistak+® Depth Filter in µPod® format, CE35 media series, 23 cm2 surface area, Luer fitting connection
134
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
MCE3523CL3
Chemistry
Cellulose (CL)
Device Configuration
µPod
Device Material
Glass fiber reinforced polypropylene
Filter Grade
CE35
Filtration Area
0.0023 m²
Gravimetric Extractables
Not Tested
Height
6.6 cm (2.6 in.)
Length
8.9 cm (3.5 in.)
Material Size
3
Maximum Differential Pressure, bar (psid)
Forward: 2.1 bar (30 psid) @ 40 °C. Reverse: 1.0 bar (15 psid) @ 40 °C
Sterilization
2 autoclave cycles of 60 minutes at 123 °C.
Trade Name
Millistak+®
Wettability
Hydrophilic
MCE4023CL3
Millistak+® Depth Filter in µPod® format, CE40 media series, 23 cm2 surface area, Luer fitting connection
134
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
MCE4023CL3
Chemistry
Cellulose (CL)
Device Configuration
µPod
Device Material
Glass fiber reinforced polypropylene
Filter Grade
CE40
Filtration Area
0.0023 m²
Gravimetric Extractables
Not Tested
Height
6.6 cm (2.6 in.)
Length
8.9 cm (3.5 in.)
Material Size
3
Maximum Differential Pressure, bar (psid)
Forward: 2.1 bar (30 psid) @ 40 °C. Reverse: 1.0 bar (15 psid) @ 40 °C
Sterilization
2 autoclave cycles of 60 minutes at 123 °C.
Trade Name
Millistak+®
Wettability
Hydrophilic
MCE4023CL3
Millistak+® Depth Filter in µPod® format, CE40 media series, 23 cm2 surface area, Luer fitting connection
134
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
MCE4023CL3
Chemistry
Cellulose (CL)
Device Configuration
µPod
Device Material
Glass fiber reinforced polypropylene
Filter Grade
CE40
Filtration Area
0.0023 m²
Gravimetric Extractables
Not Tested
Height
6.6 cm (2.6 in.)
Length
8.9 cm (3.5 in.)
Material Size
3
Maximum Differential Pressure, bar (psid)
Forward: 2.1 bar (30 psid) @ 40 °C. Reverse: 1.0 bar (15 psid) @ 40 °C
Sterilization
2 autoclave cycles of 60 minutes at 123 °C.
Trade Name
Millistak+®
Wettability
Hydrophilic
MCE4523CL3
Millistak+® Depth Filter in µPod® format, CE45 media series, 23 cm2 surface area, Luer fitting connection
134
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
MCE4523CL3
Chemistry
Cellulose (CL)
Device Configuration
µPod
Device Material
Glass fiber reinforced polypropylene
Filter Grade
CE45
Filtration Area
0.0023 m²
Gravimetric Extractables
Not Tested
Height
6.6 cm (2.6 in.)
Length
8.9 cm (3.5 in.)
Material Size
3
Maximum Differential Pressure, bar (psid)
Forward: 2.1 bar (30 psid) @ 40 °C. Reverse: 1.0 bar (15 psid) @ 40 °C
Sterilization
2 autoclave cycles of 60 minutes at 123 °C.
Trade Name
Millistak+®
Wettability
Hydrophilic
MCE4523CL3
Millistak+® Depth Filter in µPod® format, CE45 media series, 23 cm2 surface area, Luer fitting connection
134
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
MCE4523CL3
Chemistry
Cellulose (CL)
Device Configuration
µPod
Device Material
Glass fiber reinforced polypropylene
Filter Grade
CE45
Filtration Area
0.0023 m²
Gravimetric Extractables
Not Tested
Height
6.6 cm (2.6 in.)
Length
8.9 cm (3.5 in.)
Material Size
3
Maximum Differential Pressure, bar (psid)
Forward: 2.1 bar (30 psid) @ 40 °C. Reverse: 1.0 bar (15 psid) @ 40 °C
Sterilization
2 autoclave cycles of 60 minutes at 123 °C.
Trade Name
Millistak+®
Wettability
Hydrophilic
MCE5023CL3
Millistak+® Depth Filter in µPod® format, CE50 media series, 23 cm2 surface area, Luer fitting connection
134
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
MCE5023CL3
Chemistry
Cellulose (CL)
Device Configuration
µPod
Device Material
Glass fiber reinforced polypropylene
Filter Grade
CE50
Filtration Area
0.0023 m²
Gravimetric Extractables
Not Tested
Height
6.6 cm (2.6 in.)
Length
8.9 cm (3.5 in.)
Material Size
3
Maximum Differential Pressure, bar (psid)
Forward: 2.1 bar (30 psid) @ 40 °C. Reverse: 1.0 bar (15 psid) @ 40 °C
Sterilization
2 autoclave cycles of 60 minutes at 123 °C.
Trade Name
Millistak+®
Wettability
Hydrophilic
MCE5023CL3
Millistak+® Depth Filter in µPod® format, CE50 media series, 23 cm2 surface area, Luer fitting connection
134
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
MCE5023CL3
Chemistry
Cellulose (CL)
Device Configuration
µPod
Device Material
Glass fiber reinforced polypropylene
Filter Grade
CE50
Filtration Area
0.0023 m²
Gravimetric Extractables
Not Tested
Height
6.6 cm (2.6 in.)
Length
8.9 cm (3.5 in.)
Material Size
3
Maximum Differential Pressure, bar (psid)
Forward: 2.1 bar (30 psid) @ 40 °C. Reverse: 1.0 bar (15 psid) @ 40 °C
Sterilization
2 autoclave cycles of 60 minutes at 123 °C.
Trade Name
Millistak+®
Wettability
Hydrophilic
XX4404703
Back-pressure Screen, 47 mm, stainless steel
48
Add to Cart
Applicable Device
Stainless Steel Filter Holder
Background Information
Applications:In-Line Stainless Steel Filter Holders are commonly used for the filtration of gases or liquids at inlet pressures of 20 to 700 bar. Differential pressure depends on filter type used. All filter holders may be autoclaved (available in 25 mm and 47 mm).Filter holder XX4404700 is equipped with a back-pressure support screen. It may be autoclaved with filter in-place, if PTFE-coated support screens, XX4404702 and XX4404704, are used. - XX4204709, XX4304701, XX4404703, 5614, and 00907P are replacement parts for Filter Holder XX4404700.Filter holder XX4504700 may be equipped with an upstream filter support screen, XX4504704, for back-pressure protection of filter.- XX4504704, XX4504705, XX4504710, XX4504713, and XX45047RK are replacement parts for Filter Holder XX4504700.Replacement parts for the 25mm SS Filter Holder are available as a kit under Catalog Number XX45025RK, which includes: (3) stainless steel hex-cap screws, (3) LCR-treated Buna-N O-rings (2-018), (1) stainless steel support screen, (1) Allen™ wrench.
Catalogue Number
XX4404703
Diameter
47 mm
Material Size
1
Materials of Construction
Stainless steel
XX1007615
Microscope Slides
50
Add to Cart
Applicable Device
Patch Test Kit
Background Information
Accessories for filter holders for sample preparation.
Catalogue Number
XX1007615
Chemistry
Glass Fiber
Height
7.6 cm (3 in.)
Material Size
72
Width
5.0 cm (2 in.)