We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
SLGV004SL Millex-GV Filter, 0.22 µm 207 
Add to Cart
  • Availability by Geography
  • United StatesJapanCanadaEuropeAustraliaThailandMalaysia
  • Background Information
  • Available in 4, 13, 25, 33, and 50 mm diameters with a variety of membranes, Millex® sterile syringe filters are ideal for sterilizing organic solvents, aqueous solutions or air/gas. Many sample preparation methods specify Millex® filters because of their unsurpassed quality and consistency. Millex® filters not only feature minimal hold-up volume and faster flow rates, but they also withstand higher operating pressures and are chemically compatible with a range of samples and solvents to minimize leaching of extractable impurities. Millex® filters are produced in a controlled, automated environment with the highest quality standards. Sterile devices come with a certificate of quality, with select devices marked for medical applications.Features & Benefits:•Tailored to a variety of applications based on membrane type, housing and validation rating •Medical Device-rated devices in some countries including vented devices for direct patient care •Specialized filter units to protect hemodialysis transducers from blood and moisture and for vacuum line protection •Low extractables and low absorption membranes for minimum sample losses •Faster flow rates and higher operating pressures for high performance needs Applications:Sterilization of Aqueous Solutions, Organic Solvents and Gases, Filtration of High Value Protein or Small Molecule Components, Select Medical Device Applications (Some Including Direct Patient Care Depending on Country/Region)
  • Catalogue Number
  • SLGV004SL
  • Chemistry
  • Hydrophilic Polyvinylidene Fluoride (PVDF)
  • Color Code
  • Natural inlet/natural outlet
  • Device Material
  • HDPE
  • Diameter
  • 0.4 cm
  • Filter Code
  • GV
  • Filter Diameter (⌀)
  • 4 mm
  • Filtration Area
  • 0.1 cm²
  • Fitting Inlet
  • Female Luer-Lok®
  • Fitting Outlet
  • Male Luer slip, stepped
  • Height
  • 19.7 mm
  • Hold-up Volume
  • < 10 µL
  • Key Applications
  • Ultra-low protein bindingSterilization of tissue culture media, protein solutions or aqueous solutions
  • Material Size
  • PVDF, 4 mm, ethylene oxide sterilized, 100
  • Maximum Inlet Pressure, bar (psi)
  • 14 bar (200 psi)
  • Maximum Operating Temperature
  • 45 °C
  • Media
  • Durapore®
  • Pore Size
  • 0.22 µm
  • Process Volume
  • 1 mL
  • Stem Cell Type
  • Mouse Embryonic Stem CellsHuman Embryonic Stem CellsMesenchymal Stem CellsNeural Stem CellsHematopoietic Stem CellsEpithelial CellsPancreatic Stem CellsCardiac Stem CellsInduced Pluripotent Stem Cells
  • Sterility
  • Sterile
  • Sterilization
  • Ethylene oxide
  • Trade Name
  • Millex®
  • Volume
  • < 10 µL
  • Wettability
  • Hydrophilic
SLGV004SL Millex-GV Filter, 0.22 µm 207 
Add to Cart
  • Availability by Geography
  • United StatesJapanCanadaEuropeAustraliaThailandMalaysia
  • Background Information
  • Available in 4, 13, 25, 33, and 50 mm diameters with a variety of membranes, Millex® sterile syringe filters are ideal for sterilizing organic solvents, aqueous solutions or air/gas. Many sample preparation methods specify Millex® filters because of their unsurpassed quality and consistency. Millex® filters not only feature minimal hold-up volume and faster flow rates, but they also withstand higher operating pressures and are chemically compatible with a range of samples and solvents to minimize leaching of extractable impurities. Millex® filters are produced in a controlled, automated environment with the highest quality standards. Sterile devices come with a certificate of quality, with select devices marked for medical applications.Features & Benefits:•Tailored to a variety of applications based on membrane type, housing and validation rating •Medical Device-rated devices in some countries including vented devices for direct patient care •Specialized filter units to protect hemodialysis transducers from blood and moisture and for vacuum line protection •Low extractables and low absorption membranes for minimum sample losses •Faster flow rates and higher operating pressures for high performance needs Applications:Sterilization of Aqueous Solutions, Organic Solvents and Gases, Filtration of High Value Protein or Small Molecule Components, Select Medical Device Applications (Some Including Direct Patient Care Depending on Country/Region)
  • Catalogue Number
  • SLGV004SL
  • Chemistry
  • Hydrophilic Polyvinylidene Fluoride (PVDF)
  • Color Code
  • Natural inlet/natural outlet
  • Device Material
  • HDPE
  • Diameter
  • 0.4 cm
  • Filter Code
  • GV
  • Filter Diameter (⌀)
  • 4 mm
  • Filtration Area
  • 0.1 cm²
  • Fitting Inlet
  • Female Luer-Lok®
  • Fitting Outlet
  • Male Luer slip, stepped
  • Height
  • 19.7 mm
  • Hold-up Volume
  • < 10 µL
  • Key Applications
  • Ultra-low protein bindingSterilization of tissue culture media, protein solutions or aqueous solutions
  • Material Size
  • PVDF, 4 mm, ethylene oxide sterilized, 100
  • Maximum Inlet Pressure, bar (psi)
  • 14 bar (200 psi)
  • Maximum Operating Temperature
  • 45 °C
  • Media
  • Durapore®
  • Pore Size
  • 0.22 µm
  • Process Volume
  • 1 mL
  • Stem Cell Type
  • Mouse Embryonic Stem CellsHuman Embryonic Stem CellsMesenchymal Stem CellsNeural Stem CellsHematopoietic Stem CellsEpithelial CellsPancreatic Stem CellsCardiac Stem CellsInduced Pluripotent Stem Cells
  • Sterility
  • Sterile
  • Sterilization
  • Ethylene oxide
  • Trade Name
  • Millex®
  • Volume
  • < 10 µL
  • Wettability
  • Hydrophilic
SLHV004SL Millex-HV Syringe Filter Unit, 0.45 µm 207 
Add to Cart
  • Availability by Geography
  • United StatesJapanCanadaEuropeAustraliaThailandMalaysia
  • Background Information
  • Available in 4, 13, 25, 33, and 50 mm diameters with a variety of membranes, Millex® sterile syringe filters are ideal for sterilizing organic solvents, aqueous solutions or air/gas. Many sample preparation methods specify Millex® filters because of their unsurpassed quality and consistency. Millex® filters not only feature minimal hold-up volume and faster flow rates, but they also withstand higher operating pressures and are chemically compatible with a range of samples and solvents to minimize leaching of extractable impurities. Millex® filters are produced in a controlled, automated environment with the highest quality standards. Sterile devices come with a certificate of quality, with select devices marked for medical applications.Features & Benefits:•Tailored to a variety of applications based on membrane type, housing and validation rating •Medical Device-rated devices in some countries including vented devices for direct patient care •Specialized filter units to protect hemodialysis transducers from blood and moisture and for vacuum line protection •Low extractables and low absorption membranes for minimum sample losses •Faster flow rates and higher operating pressures for high performance needs Applications:Sterilization of Aqueous Solutions, Organic Solvents and Gases, Filtration of High Value Protein or Small Molecule Components, Select Medical Device Applications (Some Including Direct Patient Care Depending on Country/Region)
  • Catalogue Number
  • SLHV004SL
  • Chemistry
  • Hydrophilic Polyvinylidene Fluoride (PVDF)
  • Color Code
  • Natural inlet/natural outlet
  • Device Material
  • HDPE
  • Diameter
  • 0.4 cm
  • Filter Code
  • HV
  • Filter Diameter (⌀)
  • 4 mm
  • Filtration Area
  • 0.1 cm²
  • Fitting Inlet
  • Female Luer-Lok®
  • Fitting Outlet
  • Male Luer slip, stepped
  • Height
  • 19.7 mm
  • Hold-up Volume
  • < 10 µL
  • Key Applications
  • Ultra-low protein bindingSterilization of tissue culture media, protein solutions or aqueous solutions
  • Material Size
  • PVDF, 4 mm, ethylene oxide sterilized, 100
  • Maximum Inlet Pressure, bar (psi)
  • 14 bar (200 psi)
  • Maximum Operating Temperature
  • 45 °C
  • Media
  • Durapore®
  • Pore Size
  • 0.45 µm
  • Process Volume
  • 1 mL
  • Stem Cell Type
  • Mouse Embryonic Stem CellsHuman Embryonic Stem CellsMesenchymal Stem CellsNeural Stem CellsHematopoietic Stem CellsEpithelial CellsPancreatic Stem CellsCardiac Stem CellsInduced Pluripotent Stem Cells
  • Sterility
  • Sterile
  • Sterilization
  • Ethylene oxide
  • Trade Name
  • Millex®
  • Volume
  • < 10 µL
  • Wettability
  • Hydrophilic
SLHV004SL Millex-HV Syringe Filter Unit, 0.45 µm 207 
Add to Cart
  • Availability by Geography
  • United StatesJapanCanadaEuropeAustraliaThailandMalaysia
  • Background Information
  • Available in 4, 13, 25, 33, and 50 mm diameters with a variety of membranes, Millex® sterile syringe filters are ideal for sterilizing organic solvents, aqueous solutions or air/gas. Many sample preparation methods specify Millex® filters because of their unsurpassed quality and consistency. Millex® filters not only feature minimal hold-up volume and faster flow rates, but they also withstand higher operating pressures and are chemically compatible with a range of samples and solvents to minimize leaching of extractable impurities. Millex® filters are produced in a controlled, automated environment with the highest quality standards. Sterile devices come with a certificate of quality, with select devices marked for medical applications.Features & Benefits:•Tailored to a variety of applications based on membrane type, housing and validation rating •Medical Device-rated devices in some countries including vented devices for direct patient care •Specialized filter units to protect hemodialysis transducers from blood and moisture and for vacuum line protection •Low extractables and low absorption membranes for minimum sample losses •Faster flow rates and higher operating pressures for high performance needs Applications:Sterilization of Aqueous Solutions, Organic Solvents and Gases, Filtration of High Value Protein or Small Molecule Components, Select Medical Device Applications (Some Including Direct Patient Care Depending on Country/Region)
  • Catalogue Number
  • SLHV004SL
  • Chemistry
  • Hydrophilic Polyvinylidene Fluoride (PVDF)
  • Color Code
  • Natural inlet/natural outlet
  • Device Material
  • HDPE
  • Diameter
  • 0.4 cm
  • Filter Code
  • HV
  • Filter Diameter (⌀)
  • 4 mm
  • Filtration Area
  • 0.1 cm²
  • Fitting Inlet
  • Female Luer-Lok®
  • Fitting Outlet
  • Male Luer slip, stepped
  • Height
  • 19.7 mm
  • Hold-up Volume
  • < 10 µL
  • Key Applications
  • Ultra-low protein bindingSterilization of tissue culture media, protein solutions or aqueous solutions
  • Material Size
  • PVDF, 4 mm, ethylene oxide sterilized, 100
  • Maximum Inlet Pressure, bar (psi)
  • 14 bar (200 psi)
  • Maximum Operating Temperature
  • 45 °C
  • Media
  • Durapore®
  • Pore Size
  • 0.45 µm
  • Process Volume
  • 1 mL
  • Stem Cell Type
  • Mouse Embryonic Stem CellsHuman Embryonic Stem CellsMesenchymal Stem CellsNeural Stem CellsHematopoietic Stem CellsEpithelial CellsPancreatic Stem CellsCardiac Stem CellsInduced Pluripotent Stem Cells
  • Sterility
  • Sterile
  • Sterilization
  • Ethylene oxide
  • Trade Name
  • Millex®
  • Volume
  • < 10 µL
  • Wettability
  • Hydrophilic
SLFG55010 Millex-FG, 0.20 µm, hydrophobic PTFE, 50 mm 115 
Add to Cart
  • Background Information
  • Millex® syringe filter units with hydrophobic Fluoropore™ or Millipore Express® PLUS PES membrane are ideal for in-line sterilization of gases and venting sterile containers, and filters with Fluoropore™ membrane can also be used for sterilizing or clarifying organic solutions. There are also specialized filter units to protect hemodialysis transducers from blood and moisture. The 50 mm Millex® filter units are especially useful for vacuum line protection. All units are bi-directional.Features & Benefits:•Specialized filter units protect hemodialysis transducers from blood and moisture •50 mm Millex® units ideal for vacuum line protection •All Millex® Hydrophobic PTFE units are bi-directional in flow Applications:Sterilizing Gases, Vacuum Line Protection, Venting Sterile Containers, Sterilizing and Clarifying Organic Solutions
  • Catalogue Number
  • SLFG55010
  • Chemistry
  • Hydrophobic Polytetrafluoroethylene (PTFE)
  • Color Code
  • Natural inlet/natural outlet
  • Device Material
  • Polypropylene
  • Diameter
  • 62 mm
  • Filter Code
  • FG
  • Filter Diameter (⌀)
  • 50 mm
  • Filtration Area
  • 19.6 cm²
  • Fitting Inlet
  • Stepped Hose Barb with Female Luer slip interior
  • Fitting Outlet
  • 1/8 in. NPTM
  • Height
  • 64 mm
  • Hold-up Volume
  • < 0.1 mL
  • Key Applications
  • Analytical Sample Prep
  • Material Size
  • 50 mm, HB-NPTM, 10
  • Maximum Inlet Pressure, bar (psi)
  • 4.1 bar (60 psi)
  • Maximum Operating Temperature
  • 121 °C
  • Media
  • Fluoropore®
  • Pore Size
  • 0.2 µm
  • Process Volume
  • 4 L
  • Sterility
  • Non-Sterile
  • Sterilization
  • Autoclavable
  • Trade Name
  • Millex®
  • Volume
  • < 0.1 mL
  • Wettability
  • Hydrophobic
SLFG55010 Millex-FG, 0.20 µm, hydrophobic PTFE, 50 mm 115 
Add to Cart
  • Background Information
  • Millex® syringe filter units with hydrophobic Fluoropore™ or Millipore Express® PLUS PES membrane are ideal for in-line sterilization of gases and venting sterile containers, and filters with Fluoropore™ membrane can also be used for sterilizing or clarifying organic solutions. There are also specialized filter units to protect hemodialysis transducers from blood and moisture. The 50 mm Millex® filter units are especially useful for vacuum line protection. All units are bi-directional.Features & Benefits:•Specialized filter units protect hemodialysis transducers from blood and moisture •50 mm Millex® units ideal for vacuum line protection •All Millex® Hydrophobic PTFE units are bi-directional in flow Applications:Sterilizing Gases, Vacuum Line Protection, Venting Sterile Containers, Sterilizing and Clarifying Organic Solutions
  • Catalogue Number
  • SLFG55010
  • Chemistry
  • Hydrophobic Polytetrafluoroethylene (PTFE)
  • Color Code
  • Natural inlet/natural outlet
  • Device Material
  • Polypropylene
  • Diameter
  • 62 mm
  • Filter Code
  • FG
  • Filter Diameter (⌀)
  • 50 mm
  • Filtration Area
  • 19.6 cm²
  • Fitting Inlet
  • Stepped Hose Barb with Female Luer slip interior
  • Fitting Outlet
  • 1/8 in. NPTM
  • Height
  • 64 mm
  • Hold-up Volume
  • < 0.1 mL
  • Key Applications
  • Analytical Sample Prep
  • Material Size
  • 50 mm, HB-NPTM, 10
  • Maximum Inlet Pressure, bar (psi)
  • 4.1 bar (60 psi)
  • Maximum Operating Temperature
  • 121 °C
  • Media
  • Fluoropore®
  • Pore Size
  • 0.2 µm
  • Process Volume
  • 4 L
  • Sterility
  • Non-Sterile
  • Sterilization
  • Autoclavable
  • Trade Name
  • Millex®
  • Volume
  • < 0.1 mL
  • Wettability
  • Hydrophobic
SLFG65010 Millex-FG, 0.20 µm, hydrophobic PTFE, 50 mm 115 
Add to Cart
  • Background Information
  • Millex® syringe filter units with hydrophobic Fluoropore™ or Millipore Express® PLUS PES membrane are ideal for in-line sterilization of gases and venting sterile containers, and filters with Fluoropore™ membrane can also be used for sterilizing or clarifying organic solutions. There are also specialized filter units to protect hemodialysis transducers from blood and moisture. The 50 mm Millex® filter units are especially useful for vacuum line protection. All units are bi-directional.Features & Benefits:•Specialized filter units protect hemodialysis transducers from blood and moisture •50 mm Millex® units ideal for vacuum line protection •All Millex® Hydrophobic PTFE units are bi-directional in flow Applications:Sterilizing Gases, Vacuum Line Protection, Venting Sterile Containers, Sterilizing and Clarifying Organic Solutions
  • Catalogue Number
  • SLFG65010
  • Chemistry
  • Hydrophobic Polytetrafluoroethylene (PTFE)
  • Color Code
  • Natural inlet/natural outlet
  • Device Material
  • Polypropylene
  • Diameter
  • 62 mm
  • Filter Code
  • FG
  • Filter Diameter (⌀)
  • 50 mm
  • Filtration Area
  • 19.6 cm²
  • Fitting Inlet
  • Stepped Hose Barb with Female Luer slip interior
  • Fitting Outlet
  • 1/8 in. NPTM
  • Height
  • 64 mm
  • Hold-up Volume
  • < 0.1 mL
  • Key Applications
  • Analytical Sample Prep
  • Material Size
  • 10
  • Maximum Inlet Pressure, bar (psi)
  • 4.1 bar (60 psi)
  • Maximum Operating Temperature
  • 121 °C
  • Media
  • Fluoropore®
  • Pore Size
  • 0.2 µm
  • Process Volume
  • 4 L
  • Sterility
  • Non-Sterile
  • Sterilization
  • Autoclavable
  • Trade Name
  • Millex®
  • Volume
  • < 0.1 mL
  • Wettability
  • Hydrophobic
SLFG65010 Millex-FG, 0.20 µm, hydrophobic PTFE, 50 mm 115 
Add to Cart
  • Background Information
  • Millex® syringe filter units with hydrophobic Fluoropore™ or Millipore Express® PLUS PES membrane are ideal for in-line sterilization of gases and venting sterile containers, and filters with Fluoropore™ membrane can also be used for sterilizing or clarifying organic solutions. There are also specialized filter units to protect hemodialysis transducers from blood and moisture. The 50 mm Millex® filter units are especially useful for vacuum line protection. All units are bi-directional.Features & Benefits:•Specialized filter units protect hemodialysis transducers from blood and moisture •50 mm Millex® units ideal for vacuum line protection •All Millex® Hydrophobic PTFE units are bi-directional in flow Applications:Sterilizing Gases, Vacuum Line Protection, Venting Sterile Containers, Sterilizing and Clarifying Organic Solutions
  • Catalogue Number
  • SLFG65010
  • Chemistry
  • Hydrophobic Polytetrafluoroethylene (PTFE)
  • Color Code
  • Natural inlet/natural outlet
  • Device Material
  • Polypropylene
  • Diameter
  • 62 mm
  • Filter Code
  • FG
  • Filter Diameter (⌀)
  • 50 mm
  • Filtration Area
  • 19.6 cm²
  • Fitting Inlet
  • Stepped Hose Barb with Female Luer slip interior
  • Fitting Outlet
  • 1/8 in. NPTM
  • Height
  • 64 mm
  • Hold-up Volume
  • < 0.1 mL
  • Key Applications
  • Analytical Sample Prep
  • Material Size
  • 10
  • Maximum Inlet Pressure, bar (psi)
  • 4.1 bar (60 psi)
  • Maximum Operating Temperature
  • 121 °C
  • Media
  • Fluoropore®
  • Pore Size
  • 0.2 µm
  • Process Volume
  • 4 L
  • Sterility
  • Non-Sterile
  • Sterilization
  • Autoclavable
  • Trade Name
  • Millex®
  • Volume
  • < 0.1 mL
  • Wettability
  • Hydrophobic
SLFG75010 Millex-FG, 0.20 µm, hydrophobic PTFE, 50 mm 115 
Add to Cart
  • Background Information
  • Millex® syringe filter units with hydrophobic Fluoropore™ or Millipore Express® PLUS PES membrane are ideal for in-line sterilization of gases and venting sterile containers, and filters with Fluoropore™ membrane can also be used for sterilizing or clarifying organic solutions. There are also specialized filter units to protect hemodialysis transducers from blood and moisture. The 50 mm Millex® filter units are especially useful for vacuum line protection. All units are bi-directional.Features & Benefits:•Specialized filter units protect hemodialysis transducers from blood and moisture •50 mm Millex® units ideal for vacuum line protection •All Millex® Hydrophobic PTFE units are bi-directional in flow Applications:Sterilizing Gases, Vacuum Line Protection, Venting Sterile Containers, Sterilizing and Clarifying Organic Solutions
  • Catalogue Number
  • SLFG75010
  • Chemistry
  • Hydrophobic Polytetrafluoroethylene (PTFE)
  • Color Code
  • Natural inlet/natural outlet
  • Device Material
  • Polypropylene
  • Diameter
  • 62 mm
  • Filter Code
  • FG
  • Filter Diameter (⌀)
  • 50 mm
  • Filtration Area
  • 19.6 cm²
  • Fitting Inlet
  • 1/8 in. NPTM
  • Fitting Outlet
  • 1/8 in. NPTM
  • Height
  • 57.4 mm
  • Hold-up Volume
  • < 0.1 mL
  • Key Applications
  • Analytical Sample Prep
  • Material Size
  • 10
  • Maximum Inlet Pressure, bar (psi)
  • 4.1 bar (60 psi)
  • Maximum Operating Temperature
  • 121 °C
  • Media
  • Fluoropore®
  • Pore Size
  • 0.2 µm
  • Process Volume
  • 4 L
  • Sterility
  • Non-Sterile
  • Sterilization
  • Autoclavable
  • Trade Name
  • Millex®
  • Volume
  • < 0.1 mL
  • Wettability
  • Hydrophobic
SLFG75010 Millex-FG, 0.20 µm, hydrophobic PTFE, 50 mm 115 
Add to Cart
  • Background Information
  • Millex® syringe filter units with hydrophobic Fluoropore™ or Millipore Express® PLUS PES membrane are ideal for in-line sterilization of gases and venting sterile containers, and filters with Fluoropore™ membrane can also be used for sterilizing or clarifying organic solutions. There are also specialized filter units to protect hemodialysis transducers from blood and moisture. The 50 mm Millex® filter units are especially useful for vacuum line protection. All units are bi-directional.Features & Benefits:•Specialized filter units protect hemodialysis transducers from blood and moisture •50 mm Millex® units ideal for vacuum line protection •All Millex® Hydrophobic PTFE units are bi-directional in flow Applications:Sterilizing Gases, Vacuum Line Protection, Venting Sterile Containers, Sterilizing and Clarifying Organic Solutions
  • Catalogue Number
  • SLFG75010
  • Chemistry
  • Hydrophobic Polytetrafluoroethylene (PTFE)
  • Color Code
  • Natural inlet/natural outlet
  • Device Material
  • Polypropylene
  • Diameter
  • 62 mm
  • Filter Code
  • FG
  • Filter Diameter (⌀)
  • 50 mm
  • Filtration Area
  • 19.6 cm²
  • Fitting Inlet
  • 1/8 in. NPTM
  • Fitting Outlet
  • 1/8 in. NPTM
  • Height
  • 57.4 mm
  • Hold-up Volume
  • < 0.1 mL
  • Key Applications
  • Analytical Sample Prep
  • Material Size
  • 10
  • Maximum Inlet Pressure, bar (psi)
  • 4.1 bar (60 psi)
  • Maximum Operating Temperature
  • 121 °C
  • Media
  • Fluoropore®
  • Pore Size
  • 0.2 µm
  • Process Volume
  • 4 L
  • Sterility
  • Non-Sterile
  • Sterilization
  • Autoclavable
  • Trade Name
  • Millex®
  • Volume
  • < 0.1 mL
  • Wettability
  • Hydrophobic

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources