We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
SPGPM20RJ Steripak-GP Pressure Filter Unit 164 
Add to Cart
  • Background Information
  • Steripak-GP filter units are designed for larger scale pressure-driven filtration of tissue culture media with or without serum. They are single use and are not autoclavable. The filter units come in two sizes, with the smaller unit able to filter up to 10 L and the larger up to 20 L. Both sizes utilize the low protein binding, fast flow 0.22 µm Millipore Express membrane. Each unit has an integral filling bell for bottle-top use and a manually operated upstream air vent to prevent membrane air locking. They are supplied sterile and ready to connect to a pump or pressure vessel (not included).Steripak™-GP filter units are designed for larger scale, pressure-driven filtration of tissue culture media with or without serum. Each filter is for a single use and is not autoclavable. The filter units come in two sizes with the smaller unit able to filter up to 10 L and the larger up to 20 L.Features & Benefits: - Millipore Express® PLUS membrane for fastest flow rates and low protein binding - Larger scale, pressure-driven filtration device for faster flow rates speeds time-consuming, large-volume filtrations - 10 L and 20 L capacity sizes for maximum laboratory-scale filtration options - Manually operated top air vent to prevent air lock stop of flow - Filling bell for cleaner filling environment around the opening of the receptacle bottle Applications:Sterilization of Aqueous Solutions, Media Preparation, Buffer Preparation
  • Catalogue Number
  • SPGPM20RJ
  • Chemistry
  • Polyethersulfone (PES)
  • Color Code
  • Clear inlet/blue outlet
  • Device Material
  • SAN
  • Diameter
  • 9.9 cm
  • Filter Diameter (⌀)
  • 160 mm
  • Filtration Area
  • 200 cm²
  • Fitting Inlet
  • 6 mm (1/4 in.) stepped Hose Barb
  • Fitting Outlet
  • 6 mm (1/4 in.) stepped Hose Barb and filling bell
  • Height
  • 76 mm
  • Hold-up Volume
  • 2.7 mL
  • Key Applications
  • Sterile Filtration
  • Material Size
  • 3
  • Maximum Inlet Pressure, bar (psi)
  • Forward: 5.2 bar (75 psi); Reverse: 0.35 bar (5 psi)
  • Maximum Operating Temperature
  • 45 °C
  • Media
  • Express PLUS®
  • Nominal Pore Size
  • 0.22 µm
  • Pore Size
  • 0.22 µm
  • Process Volume
  • 20 L
  • Sterility
  • Sterile
  • Sterilization
  • Gamma irradiation
  • Trade Name
  • Steripak
  • Volume
  • 2.7 mL
  • Wettability
  • Hydrophilic
SVGP01015 Sterivex-GP Pressure Filter Unit 100 
Add to Cart
  • Background Information
  • - Sterivex filter units work with syringes, peristaltic pumps or pressure vessels. They eliminate the risk of contamination associated with decanting or pipetting. - Sterivex units are designed to dispense into virtually any storage container. The devices are available with different outlet connections (see table). - Sterivex filter units can process volumes up to 1,000 mL or 2,000 mL, depending on the type of membrane used in the device. A choice of three different membranes is provided. - Filter-sterilize volumes up to 1,000 mL or 2,000 mL, using Sterivex™ pressure-driven filter units (capacity depends on the type of membrane used in the device). With three different membrane options and a variety of outlet connection options, Sterivex™ filters can fit virtually any workflow and dispense into nearly any storage container. Sterivex™ filters work with syringes, peristaltic pumps or pressure vessels and eliminate the risk of contamination associated with decanting or pipetting.Features & Benefits: - Works with a variety of pressure devices including syringes, perstaltic pumps and pressure vessels - Comes in multiple membrane types to suit your application needs with capacities up to 2 L Applications:Sterilization of Aqueous Solutions
  • Catalogue Number
  • SVGP01015
  • Chemistry
  • Polyethersulfone (PES)
  • Color Code
  • Clear
  • Device Material
  • Eastar®
  • Diameter
  • 1.7 cm
  • Filtration Area
  • 10 cm²
  • Fitting Inlet
  • Female Luer-Lok® with upstream vent
  • Fitting Outlet
  • Male nipple
  • Height
  • 67 mm
  • Hold-up Volume
  • 2.2 mL
  • Key Applications
  • Sterile Filtration
  • Material Size
  • 15
  • Maximum Inlet Pressure, bar (psi)
  • 3.1 bar (45 psi)
  • Maximum Operating Temperature
  • 45 °C
  • Media
  • Express PLUS®
  • Nominal Pore Size
  • 0.22 µm
  • Pore Size
  • 0.22 µm
  • Process Volume
  • 2 L
  • Sterility
  • Sterile
  • Sterilization
  • Gamma irradiation
  • Trade Name
  • Sterivex
  • Volume
  • 2.2 mL
  • Wettability
  • Hydrophilic
SVGP01015 Sterivex-GP Pressure Filter Unit 100 
Add to Cart
  • Background Information
  • - Sterivex filter units work with syringes, peristaltic pumps or pressure vessels. They eliminate the risk of contamination associated with decanting or pipetting. - Sterivex units are designed to dispense into virtually any storage container. The devices are available with different outlet connections (see table). - Sterivex filter units can process volumes up to 1,000 mL or 2,000 mL, depending on the type of membrane used in the device. A choice of three different membranes is provided. - Filter-sterilize volumes up to 1,000 mL or 2,000 mL, using Sterivex™ pressure-driven filter units (capacity depends on the type of membrane used in the device). With three different membrane options and a variety of outlet connection options, Sterivex™ filters can fit virtually any workflow and dispense into nearly any storage container. Sterivex™ filters work with syringes, peristaltic pumps or pressure vessels and eliminate the risk of contamination associated with decanting or pipetting.Features & Benefits: - Works with a variety of pressure devices including syringes, perstaltic pumps and pressure vessels - Comes in multiple membrane types to suit your application needs with capacities up to 2 L Applications:Sterilization of Aqueous Solutions
  • Catalogue Number
  • SVGP01015
  • Chemistry
  • Polyethersulfone (PES)
  • Color Code
  • Clear
  • Device Material
  • Eastar®
  • Diameter
  • 1.7 cm
  • Filtration Area
  • 10 cm²
  • Fitting Inlet
  • Female Luer-Lok® with upstream vent
  • Fitting Outlet
  • Male nipple
  • Height
  • 67 mm
  • Hold-up Volume
  • 2.2 mL
  • Key Applications
  • Sterile Filtration
  • Material Size
  • 15
  • Maximum Inlet Pressure, bar (psi)
  • 3.1 bar (45 psi)
  • Maximum Operating Temperature
  • 45 °C
  • Media
  • Express PLUS®
  • Nominal Pore Size
  • 0.22 µm
  • Pore Size
  • 0.22 µm
  • Process Volume
  • 2 L
  • Sterility
  • Sterile
  • Sterilization
  • Gamma irradiation
  • Trade Name
  • Sterivex
  • Volume
  • 2.2 mL
  • Wettability
  • Hydrophilic
SVGP01050 Sterivex-GP Pressure Filter Unit 217 
Add to Cart
  • Background Information
  • - Sterivex filter units work with syringes, peristaltic pumps or pressure vessels. They eliminate the risk of contamination associated with decanting or pipetting. - Sterivex units are designed to dispense into virtually any storage container. The devices are available with different outlet connections (see table). - Sterivex filter units can process volumes up to 1,000 mL or 2,000 mL, depending on the type of membrane used in the device. A choice of three different membranes is provided. - Filter-sterilize volumes up to 1,000 mL or 2,000 mL, using Sterivex™ pressure-driven filter units (capacity depends on the type of membrane used in the device). With three different membrane options and a variety of outlet connection options, Sterivex™ filters can fit virtually any workflow and dispense into nearly any storage container. Sterivex™ filters work with syringes, peristaltic pumps or pressure vessels and eliminate the risk of contamination associated with decanting or pipetting.Features & Benefits: - Works with a variety of pressure devices including syringes, perstaltic pumps and pressure vessels - Comes in multiple membrane types to suit your application needs with capacities up to 2 L Applications:Sterilization of Aqueous Solutions
  • Catalogue Number
  • SVGP01050
  • Chemistry
  • Polyethersulfone (PES)
  • Color Code
  • Clear
  • Device Material
  • Eastar®
  • Diameter
  • 1.7 cm
  • Filtration Area
  • 10 cm²
  • Fitting Inlet
  • Female Luer-Lok® with upstream vent
  • Fitting Outlet
  • Male nipple
  • Height
  • 67 mm
  • Hold-up Volume
  • 2.2 mL
  • Key Applications
  • Sterile Filtration
  • Material Size
  • 50
  • Maximum Inlet Pressure, bar (psi)
  • 3.1 bar (45 psi)
  • Maximum Operating Temperature
  • 45 °C
  • Media
  • Express PLUS®
  • Nominal Pore Size
  • 0.22 µm
  • Pore Size
  • 0.22 µm
  • Process Volume
  • 2 L
  • Sterility
  • Sterile
  • Sterilization
  • Gamma irradiation
  • Trade Name
  • Sterivex
  • Volume
  • 2.2 mL
  • Wettability
  • Hydrophilic
SVGP01050 Sterivex-GP Pressure Filter Unit 217 
Add to Cart
  • Background Information
  • - Sterivex filter units work with syringes, peristaltic pumps or pressure vessels. They eliminate the risk of contamination associated with decanting or pipetting. - Sterivex units are designed to dispense into virtually any storage container. The devices are available with different outlet connections (see table). - Sterivex filter units can process volumes up to 1,000 mL or 2,000 mL, depending on the type of membrane used in the device. A choice of three different membranes is provided. - Filter-sterilize volumes up to 1,000 mL or 2,000 mL, using Sterivex™ pressure-driven filter units (capacity depends on the type of membrane used in the device). With three different membrane options and a variety of outlet connection options, Sterivex™ filters can fit virtually any workflow and dispense into nearly any storage container. Sterivex™ filters work with syringes, peristaltic pumps or pressure vessels and eliminate the risk of contamination associated with decanting or pipetting.Features & Benefits: - Works with a variety of pressure devices including syringes, perstaltic pumps and pressure vessels - Comes in multiple membrane types to suit your application needs with capacities up to 2 L Applications:Sterilization of Aqueous Solutions
  • Catalogue Number
  • SVGP01050
  • Chemistry
  • Polyethersulfone (PES)
  • Color Code
  • Clear
  • Device Material
  • Eastar®
  • Diameter
  • 1.7 cm
  • Filtration Area
  • 10 cm²
  • Fitting Inlet
  • Female Luer-Lok® with upstream vent
  • Fitting Outlet
  • Male nipple
  • Height
  • 67 mm
  • Hold-up Volume
  • 2.2 mL
  • Key Applications
  • Sterile Filtration
  • Material Size
  • 50
  • Maximum Inlet Pressure, bar (psi)
  • 3.1 bar (45 psi)
  • Maximum Operating Temperature
  • 45 °C
  • Media
  • Express PLUS®
  • Nominal Pore Size
  • 0.22 µm
  • Pore Size
  • 0.22 µm
  • Process Volume
  • 2 L
  • Sterility
  • Sterile
  • Sterilization
  • Gamma irradiation
  • Trade Name
  • Sterivex
  • Volume
  • 2.2 mL
  • Wettability
  • Hydrophilic
SVGPB1010 Sterivex-GP Pressure Filter Unit 73 
Add to Cart
  • Background Information
  • - Sterivex filter units work with syringes, peristaltic pumps or pressure vessels. They eliminate the risk of contamination associated with decanting or pipetting. - Sterivex units are designed to dispense into virtually any storage container. The devices are available with different outlet connections (see table). - Sterivex filter units can process volumes up to 1,000 mL or 2,000 mL, depending on the type of membrane used in the device. A choice of three different membranes is provided. - Filter-sterilize volumes up to 1,000 mL or 2,000 mL, using Sterivex™ pressure-driven filter units (capacity depends on the type of membrane used in the device). With three different membrane options and a variety of outlet connection options, Sterivex™ filters can fit virtually any workflow and dispense into nearly any storage container. Sterivex™ filters work with syringes, peristaltic pumps or pressure vessels and eliminate the risk of contamination associated with decanting or pipetting.Features & Benefits: - Works with a variety of pressure devices including syringes, perstaltic pumps and pressure vessels - Comes in multiple membrane types to suit your application needs with capacities up to 2 L Applications:Sterilization of Aqueous Solutions
  • Catalogue Number
  • SVGPB1010
  • Chemistry
  • Polyethersulfone (PES)
  • Color Code
  • Clear
  • Device Material
  • Eastar®
  • Diameter
  • 5.4 cm
  • Filtration Area
  • 10 cm²
  • Fitting Inlet
  • Female Luer-Lok® with upstream vent
  • Fitting Outlet
  • Filling bell
  • Height
  • 85 mm
  • Hold-up Volume
  • 2.2 mL
  • Key Applications
  • Sterile Filtration
  • Material Size
  • 10
  • Maximum Inlet Pressure, bar (psi)
  • 3.1 bar (45 psi)
  • Maximum Operating Temperature
  • 45 °C
  • Media
  • Express PLUS®
  • Nominal Pore Size
  • 0.22 µm
  • Pore Size
  • 0.22 µm
  • Process Volume
  • 2 L
  • Sterility
  • Sterile
  • Sterilization
  • Gamma irradiation
  • Trade Name
  • Sterivex
  • Volume
  • 2.2 mL
  • Wettability
  • Hydrophilic
SVGPB1010 Sterivex-GP Pressure Filter Unit 73 
Add to Cart
  • Background Information
  • - Sterivex filter units work with syringes, peristaltic pumps or pressure vessels. They eliminate the risk of contamination associated with decanting or pipetting. - Sterivex units are designed to dispense into virtually any storage container. The devices are available with different outlet connections (see table). - Sterivex filter units can process volumes up to 1,000 mL or 2,000 mL, depending on the type of membrane used in the device. A choice of three different membranes is provided. - Filter-sterilize volumes up to 1,000 mL or 2,000 mL, using Sterivex™ pressure-driven filter units (capacity depends on the type of membrane used in the device). With three different membrane options and a variety of outlet connection options, Sterivex™ filters can fit virtually any workflow and dispense into nearly any storage container. Sterivex™ filters work with syringes, peristaltic pumps or pressure vessels and eliminate the risk of contamination associated with decanting or pipetting.Features & Benefits: - Works with a variety of pressure devices including syringes, perstaltic pumps and pressure vessels - Comes in multiple membrane types to suit your application needs with capacities up to 2 L Applications:Sterilization of Aqueous Solutions
  • Catalogue Number
  • SVGPB1010
  • Chemistry
  • Polyethersulfone (PES)
  • Color Code
  • Clear
  • Device Material
  • Eastar®
  • Diameter
  • 5.4 cm
  • Filtration Area
  • 10 cm²
  • Fitting Inlet
  • Female Luer-Lok® with upstream vent
  • Fitting Outlet
  • Filling bell
  • Height
  • 85 mm
  • Hold-up Volume
  • 2.2 mL
  • Key Applications
  • Sterile Filtration
  • Material Size
  • 10
  • Maximum Inlet Pressure, bar (psi)
  • 3.1 bar (45 psi)
  • Maximum Operating Temperature
  • 45 °C
  • Media
  • Express PLUS®
  • Nominal Pore Size
  • 0.22 µm
  • Pore Size
  • 0.22 µm
  • Process Volume
  • 2 L
  • Sterility
  • Sterile
  • Sterilization
  • Gamma irradiation
  • Trade Name
  • Sterivex
  • Volume
  • 2.2 mL
  • Wettability
  • Hydrophilic
SVGPL10RC Sterivex-GP Pressure Filter Unit 115 
Add to Cart
  • Background Information
  • - Sterivex filter units work with syringes, peristaltic pumps or pressure vessels. They eliminate the risk of contamination associated with decanting or pipetting. - Sterivex units are designed to dispense into virtually any storage container. The devices are available with different outlet connections (see table). - Sterivex filter units can process volumes up to 1,000 mL or 2,000 mL, depending on the type of membrane used in the device. A choice of three different membranes is provided. - Filter-sterilize volumes up to 1,000 mL or 2,000 mL, using Sterivex™ pressure-driven filter units (capacity depends on the type of membrane used in the device). With three different membrane options and a variety of outlet connection options, Sterivex™ filters can fit virtually any workflow and dispense into nearly any storage container. Sterivex™ filters work with syringes, peristaltic pumps or pressure vessels and eliminate the risk of contamination associated with decanting or pipetting.Features & Benefits: - Works with a variety of pressure devices including syringes, perstaltic pumps and pressure vessels - Comes in multiple membrane types to suit your application needs with capacities up to 2 L Applications:Sterilization of Aqueous Solutions
  • Catalogue Number
  • SVGPL10RC
  • Chemistry
  • Polyethersulfone (PES)
  • Color Code
  • Clear
  • Device Material
  • Eastar®
  • Diameter
  • 1.7 cm
  • Filtration Area
  • 10 cm²
  • Fitting Inlet
  • Female Luer-Lok® with upstream vent
  • Fitting Outlet
  • Male Luer-Lok®
  • Height
  • 82 mm
  • Hold-up Volume
  • 2.2 mL
  • Key Applications
  • Sterile Filtration
  • Material Size
  • 15
  • Maximum Inlet Pressure, bar (psi)
  • 3.1 bar (45 psi)
  • Maximum Operating Temperature
  • 45 °C
  • Media
  • Express PLUS®
  • Nominal Pore Size
  • 0.22 µm
  • Pore Size
  • 0.22 µm
  • Process Volume
  • 2 L
  • Sterility
  • Sterile
  • Sterilization
  • Gamma irradiation
  • Trade Name
  • Sterivex
  • Volume
  • 2.2 mL
  • Wettability
  • Hydrophilic
SVGPL10RC Sterivex-GP Pressure Filter Unit 115 
Add to Cart
  • Background Information
  • - Sterivex filter units work with syringes, peristaltic pumps or pressure vessels. They eliminate the risk of contamination associated with decanting or pipetting. - Sterivex units are designed to dispense into virtually any storage container. The devices are available with different outlet connections (see table). - Sterivex filter units can process volumes up to 1,000 mL or 2,000 mL, depending on the type of membrane used in the device. A choice of three different membranes is provided. - Filter-sterilize volumes up to 1,000 mL or 2,000 mL, using Sterivex™ pressure-driven filter units (capacity depends on the type of membrane used in the device). With three different membrane options and a variety of outlet connection options, Sterivex™ filters can fit virtually any workflow and dispense into nearly any storage container. Sterivex™ filters work with syringes, peristaltic pumps or pressure vessels and eliminate the risk of contamination associated with decanting or pipetting.Features & Benefits: - Works with a variety of pressure devices including syringes, perstaltic pumps and pressure vessels - Comes in multiple membrane types to suit your application needs with capacities up to 2 L Applications:Sterilization of Aqueous Solutions
  • Catalogue Number
  • SVGPL10RC
  • Chemistry
  • Polyethersulfone (PES)
  • Color Code
  • Clear
  • Device Material
  • Eastar®
  • Diameter
  • 1.7 cm
  • Filtration Area
  • 10 cm²
  • Fitting Inlet
  • Female Luer-Lok® with upstream vent
  • Fitting Outlet
  • Male Luer-Lok®
  • Height
  • 82 mm
  • Hold-up Volume
  • 2.2 mL
  • Key Applications
  • Sterile Filtration
  • Material Size
  • 15
  • Maximum Inlet Pressure, bar (psi)
  • 3.1 bar (45 psi)
  • Maximum Operating Temperature
  • 45 °C
  • Media
  • Express PLUS®
  • Nominal Pore Size
  • 0.22 µm
  • Pore Size
  • 0.22 µm
  • Process Volume
  • 2 L
  • Sterility
  • Sterile
  • Sterilization
  • Gamma irradiation
  • Trade Name
  • Sterivex
  • Volume
  • 2.2 mL
  • Wettability
  • Hydrophilic
SVGV01015 Sterivex-GV Pressure Filter Unit 100 
Add to Cart
  • Background Information
  • - Sterivex filter units work with syringes, peristaltic pumps or pressure vessels. They eliminate the risk of contamination associated with decanting or pipetting. - Sterivex units are designed to dispense into virtually any storage container. The devices are available with different outlet connections (see table). - Sterivex filter units can process volumes up to 1,000 mL or 2,000 mL, depending on the type of membrane used in the device. A choice of three different membranes is provided. - Filter-sterilize volumes up to 1,000 mL or 2,000 mL, using Sterivex™ pressure-driven filter units (capacity depends on the type of membrane used in the device). With three different membrane options and a variety of outlet connection options, Sterivex™ filters can fit virtually any workflow and dispense into nearly any storage container. Sterivex™ filters work with syringes, peristaltic pumps or pressure vessels and eliminate the risk of contamination associated with decanting or pipetting.Features & Benefits: - Works with a variety of pressure devices including syringes, perstaltic pumps and pressure vessels - Comes in multiple membrane types to suit your application needs with capacities up to 2 L Applications:Sterilization of Aqueous Solutions
  • Catalogue Number
  • SVGV01015
  • Chemistry
  • Hydrophilic Polyvinylidene Fluoride (PVDF)
  • Color Code
  • Clear
  • Device Material
  • Eastar®
  • Diameter
  • 1.7 cm
  • Filtration Area
  • 10 cm²
  • Fitting Inlet
  • Female Luer-Lok® with upstream vent
  • Fitting Outlet
  • Male nipple
  • Height
  • 67 mm
  • Hold-up Volume
  • 2.2 mL
  • Key Applications
  • Sterile Filtration
  • Material Size
  • 15
  • Maximum Inlet Pressure, bar (psi)
  • 3.1 bar (45 psi)
  • Maximum Operating Temperature
  • 45 °C
  • Media
  • Durapore®
  • Nominal Pore Size
  • 0.22 µm
  • Pore Size
  • 0.22 µm
  • Process Volume
  • 1000 mL
  • Sterility
  • Sterile
  • Sterilization
  • Gamma irradiation
  • Trade Name
  • Sterivex
  • Volume
  • 2.2 mL
  • Wettability
  • Hydrophilic

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources