Catalog No. Product Net Price
CYT29036230 Superdex 75 3.2/300 Special offer 
Add to Cart
  • Bed volume
  • 2.4
  • Flow rate
  • 0.01 ml/min-0.10 ml/min
  • Pressure max. (over the packed bed during operation)
  • 24 bar [2.4 MPa] (348 psi)
  • Pack size
  • 1
  • Bed height
  • 300 mm
  • Order Information
  • Not suitable for use with ÄKTAprime plus system
  • Column i.d.
  • 3.2
  • Sample volume
  • Up to 50 µl
  • Storage
  • 4 to 30°C, 20% Ethanol
  • Bed dimensions
  • 3.2 × 300 mm
CYT29148722 Superdex™ 75 Increase 5/150 GL 2989.5 
Add to Cart
  • Bed volume
  • ~ 24 mL
  • Bed height
  • 300 to 310 mm
  • Bed support
  • Filter
  • Material (bed support)
  • Polyethylene (PE) filter
  • Material (column tube)
  • Borosilicate glass
  • Column i.d.
  • 10
  • Chemical stability
  • Conditions where the resin may be operated without significant change in function:
    • All commonly used aqueous buffers, pH 3 to 12
    • Urea, up to 8 M
    • Ionic and nonionic detergents, e.g., 1% SDS
    • Guanidine hydrochloride, up to 6 M
    • Acetic acid, up to 1 M
    • Methanol, up to 10%
    • Isopropanol, up to 5%
    • Dithiothreitol (DTT), up to 5 mM
    • Sodium hydroxide, up to 0.5 M
    Conditions where the resin can be subjected to cleaning- or sanitization-in-place without significant change in function:
    • Acetonitrile, up to 30%
    • Sodium hydroxide, up to 1 M
    • Ethanol, up to 70%
    • Methanol, up to 70%
    • Isopropanol, up to 30%
    • Hydrochloric acid, up to 0.1 M
    • Trifluoroacetic acid, up to 1%
    • Formic acid, up to 70%
    Avoid:
    • Oxidizing agents
    • Unfiltered samples and eluents
  • Sample volume
  • 25 to 500 µL
  • Bed dimensions
  • 10 × 300 mm
  • Matrix
  • Composite of cross-linked agarose and dextran
  • pH stability, operational
  • 3 to 12
  • Theoretical plates
  • > 43 000 m-1
CYT29148721 Superdex™ 75 Increase 10/300 GL 3012 
Add to Cart
  • Bed volume
  • ~ 24 mL
  • Bed height
  • 300 to 310 mm
  • Bed support
  • Filter
  • Material (bed support)
  • Polyethylene (PE) filter
  • Material (column tube)
  • Borosilicate glass
  • Column i.d.
  • 10
  • Chemical stability
  • Conditions where the resin may be operated without significant change in function:
    • All commonly used aqueous buffers, pH 3 to 12
    • Urea, up to 8 M
    • Ionic and nonionic detergents, e.g., 1% SDS
    • Guanidine hydrochloride, up to 6 M
    • Acetic acid, up to 1 M
    • Methanol, up to 10%
    • Isopropanol, up to 5%
    • Dithiothreitol (DTT), up to 5 mM
    • Sodium hydroxide, up to 0.5 M
    Conditions where the resin can be subjected to cleaning- or sanitization-in-place without significant change in function:
    • Acetonitrile, up to 30%
    • Sodium hydroxide, up to 1 M
    • Ethanol, up to 70%
    • Methanol, up to 70%
    • Isopropanol, up to 30%
    • Hydrochloric acid, up to 0.1 M
    • Trifluoroacetic acid, up to 1%
    • Formic acid, up to 70%
    Avoid:
    • Oxidizing agents
    • Unfiltered samples and eluents
  • Sample volume
  • 25 to 500 µL
  • Bed dimensions
  • 10 × 300 mm
  • Matrix
  • Composite of cross-linked agarose and dextran
  • pH stability, operational
  • 3 to 12
  • Theoretical plates
  • > 43 000 m-1
CYT29148723 Superdex™ 75 Increase 3.2/300 3612 
Add to Cart
  • Bed volume
  • ~ 24 mL
  • Bed height
  • 300 to 310 mm
  • Bed support
  • Filter
  • Material (bed support)
  • Polyethylene (PE) filter
  • Material (column tube)
  • Borosilicate glass
  • Column i.d.
  • 10
  • Chemical stability
  • Conditions where the resin may be operated without significant change in function:
    • All commonly used aqueous buffers, pH 3 to 12
    • Urea, up to 8 M
    • Ionic and nonionic detergents, e.g., 1% SDS
    • Guanidine hydrochloride, up to 6 M
    • Acetic acid, up to 1 M
    • Methanol, up to 10%
    • Isopropanol, up to 5%
    • Dithiothreitol (DTT), up to 5 mM
    • Sodium hydroxide, up to 0.5 M
    Conditions where the resin can be subjected to cleaning- or sanitization-in-place without significant change in function:
    • Acetonitrile, up to 30%
    • Sodium hydroxide, up to 1 M
    • Ethanol, up to 70%
    • Methanol, up to 70%
    • Isopropanol, up to 30%
    • Hydrochloric acid, up to 0.1 M
    • Trifluoroacetic acid, up to 1%
    • Formic acid, up to 70%
    Avoid:
    • Oxidizing agents
    • Unfiltered samples and eluents
  • Sample volume
  • 25 to 500 µL
  • Bed dimensions
  • 10 × 300 mm
  • Matrix
  • Composite of cross-linked agarose and dextran
  • pH stability, operational
  • 3 to 12
  • Theoretical plates
  • > 43 000 m-1
CYT29036225 Superose 12 3.2/300 Special offer 
Add to Cart
  • Bed volume
  • 2.4
  • Flow rate
  • 0.01 ml/min-0.10 ml/min
  • Pressure max. (over the packed bed during operation)
  • 24 bar [2.4MPa] (350 psi)
  • Bed height
  • 300 mm
  • Order Information
  • Not suitable for use with ÄKTAprime plus system
  • Column i.d.
  • 3.2
  • Sample volume
  • 4 - 50 µl
  • Storage
  • 4 to 30°C
  • Bed dimensions
  • 3.2 × 300 mm
  • Theoretical plates
  • > 40000 m-1
CYT28950515 HiScreen SP HP 190.5 
Add to Cart
  • Bed volume
  • 4.7
  • Pressure max. (over the packed bed during operation)
  • 3 bar [0.3 MPa] (44 psi)
  • Pack size
  • 1 × 4.7 mL
  • Bed height
  • 100 mm
  • Column i.d.
  • 7.7
  • Storage
  • 4 to 30ºC, 20% Ethanol, 0.2 M Sodium Acetate
  • Bed dimensions
  • 7.7 × 100 mm
  • Flow velocity
  • < 150 cm/h
CYT28936551 HisPrep FF 16/10 699 
Add to Cart
  • Pack size
  • 20 mL
CYT29048586 HisTrap excel, 1 x 1 ml 87 
Add to Cart
  • Chromatography technique
  • Histidine-tagged protein purification
  • Bed volume
  • 1
  • Flow rate
  • 1 ml/min - 4 ml/min
  • Pressure max. (over the packed bed during operation)
  • 5 bar [0.5 MPa] (70 psi)
  • Pack size
  • 5 × 1 mL
  • Bed height
  • 25 mm
  • Column i.d.
  • 7
  • Binding Capacity/Column
  • At least 10 mg histidine-tagged protein/ml sedimented medium.
  • Storage
  • 4 to 30°C, 20% ethanol
  • Bed dimensions
  • 7 × 25 mm
CYT17371205 HisTrap excel, 5 x 1 ml 340.5 
Add to Cart
  • Chromatography technique
  • Histidine-tagged protein purification
  • Bed volume
  • 1
  • Flow rate
  • 1 ml/min - 4 ml/min
  • Pressure max. (over the packed bed during operation)
  • 5 bar [0.5 MPa] (70 psi)
  • Pack size
  • 5 × 1 mL
  • Bed height
  • 25 mm
  • Column i.d.
  • 7
  • Binding Capacity/Column
  • At least 10 mg histidine-tagged protein/ml sedimented medium.
  • Storage
  • 4 to 30°C, 20% ethanol
  • Bed dimensions
  • 7 × 25 mm
CYT17371206 HisTrap excel, 5 x 5 ml 1111.5 
Add to Cart
  • Chromatography technique
  • Histidine-tagged protein purification
  • Bed volume
  • 1
  • Flow rate
  • 1 ml/min - 4 ml/min
  • Pressure max. (over the packed bed during operation)
  • 5 bar [0.5 MPa] (70 psi)
  • Pack size
  • 5 × 1 mL
  • Bed height
  • 25 mm
  • Column i.d.
  • 7
  • Binding Capacity/Column
  • At least 10 mg histidine-tagged protein/ml sedimented medium.
  • Storage
  • 4 to 30°C, 20% ethanol
  • Bed dimensions
  • 7 × 25 mm

Overview

Affinity antibody

Prepacked protein A columns, protein G columns, and other antibody affinity purification products


Affinity specific groups

Affinity chromatography products for purification of proteins or other biomolecules from complex mixtures.


Affinity tagged protein

Purification of tagged proteins including fusions with GST, histidine, Strep-tag™ II, and MBP


Desalting and buffer exchange

Desalting columns remove salts from biological samples prior to further purification or end use.


Hydrophobic interaction

Use prepacked HIC chromatography columns for protein capture, intermediate purification, or polishing steps.


Immunoprecipitation

Use immunoprecipitation columns to isolate small amounts of target proteins


Ion exchange

Use ion exchange columns to enhance your biomolecule purification processes


Multimodal columns

Use multimodal or mixed mode chromatography for increased selectivity, high salt conditions, or process efficiency.


Reversed phase

Reverse phase chromatography columns for high-resolution separations


Size exclusion

Use size exclusion columns to separate proteins and other biomolecules based on size and shape.