CYT29005066
DNA Tray
993
Add to Cart
CYT29011350
Loop Holder
1005
Add to Cart
CYT18114724
Mixer M-925 Mixing Chamber, 90
1038
Add to Cart
For use with
Mixer M-925
Material
Polyetheretherketone (PEEK)
Connections
Fingertight connector
Operating pressure max.
250 bar (25 MPa) at 0.001 to 10 ml/min (3625 psi at 0.001 to 10 ml/min)
Chemical stability
The wetted parts are resistant to organic solvents and salt buffers commonly used in chromatography of biomolecules, except 100% Ethylacetate, 100% Hexane, and 100% Tetrahydrofuran (THF).
Wetted Materials
Polyetheretherketone (PEEK)
Wetted Part
Yes
Relative humidity
10%-95% (non condensing)
pH Stability Long Term
1-13
pH Stability Short Term
1–14
CYT18111890
Mixer M-925 Mixing Chamber, 0.6 ml
1089
Add to Cart
For use with
Mixer M-925
Material
Polyetheretherketone (PEEK)
Connections
Fingertight connector
Operating pressure max.
250 bar (25 MPa) at 0.001 to 10 ml/min (3625 psi at 0.001 to 10 ml/min)
Chemical stability
The wetted parts are resistant to organic solvents and salt buffers commonly used in chromatography of biomolecules, except 100% Ethylacetate, 100% Hexane, and 100% Tetrahydrofuran (THF).
Wetted Materials
Polyetheretherketone (PEEK)
Wetted Part
Yes
Relative humidity
10%-95% (non condensing)
pH Stability Long Term
1-13
pH Stability Short Term
1–14
CYT18112035
Syringe, 250
1113
Add to Cart
CYT28956270
Column Holder Rod
1123.5
Add to Cart
For use with
HiTrap and Tricorn columns
Wetted Materials
Polyetheretherketone (PEEK)/Stainless Steel
Wetted Part
No
Guidance
Fitting 1/16\
CYT56410603
Pressure Gauge 0-2 barg (0-30 psig) 50 mm
1156.5
Add to Cart
Material
Brass\nStainless Steel\nPlastic
Autoclavable
No
Connections
Threaded on a 25 mm TC (0.75 inch TC) connector
Operating pressure max.
2 bar (30 psi)
Wetted Part
Yes
Application
No
Guidance
Pressure gauge 0-4 barg (0-60 psig) with the same threaded connections is also available
CYT56410604
Pressure Gauge 0-4 barg (0-60 psig) 50 mm
1156.5
Add to Cart
Material
Brass\nStainless Steel\nPlastic
Autoclavable
No
Connections
Threaded on a 25 mm TC (0.75 inch TC) connector
Operating pressure max.
2 bar (30 psi)
Wetted Part
Yes
Application
No
Guidance
Pressure gauge 0-4 barg (0-60 psig) with the same threaded connections is also available
CYT12410238
Sensor Assembly, SciLog temperature sensor
531
Add to Cart
Autoclavable
Yes
Connections
ReadyMate
Certificate of Analysis
Yes
Sterility
Each component is sterile for all fluid-contact surfaces (per AAMI TIR 33:2005 and the principles of ISO/AAMI/ASTM 11137-1:2006).
Animal Free Compliance
Animal-free Origin for wetted parts per EMEA/410/01 (alternatively-manufacturing under denaturing conditions).
Compatibility
Compatible with most sanitizing agents such as NaOH, hypochlorite, for flow cell sanitization.
Endotoxin
For process fluid contact surfaces, endotoxin level is <0.25 EU/ml using water extraction method.
Hemolysis Testing
Hemolysis, ISO 10993-4
Material (Fluid Contact)
Medical grade Polysulfone (PS) meets USP 88 Class VI and FDA 21CFR177.1520.
Material Compliance
USP Biological Safety, Class VI for wetted parts, USP 88 plastics requirements and FDA 21CFR177.1520.
Sensor Isolation
Insoluble silicone dielectric gel isolates sensing element from process solution. The gel is a non toxic, nonallergenic elastomer system.
Sensor Microchip
EPROM-Stored sensor ID and calibration factor.
Sensor Type
Medical grade, silicone piezoresistive sensing element with on-chip temperature compensation
Temperature Range
0°C to 60°C
Tubing i.d.
1.9 mm (0.75 in)
CYT12410243
Sensor Assembly, SciLog conductivity sensor
531
Add to Cart
Autoclavable
Yes
Connections
ReadyMate
Certificate of Analysis
Yes
Sterility
Each component is sterile for all fluid-contact surfaces (per AAMI TIR 33:2005 and the principles of ISO/AAMI/ASTM 11137-1:2006).
Animal Free Compliance
Animal-free Origin for wetted parts per EMEA/410/01 (alternatively-manufacturing under denaturing conditions).
Compatibility
Compatible with most sanitizing agents such as NaOH, hypochlorite, for flow cell sanitization.
Endotoxin
For process fluid contact surfaces, endotoxin level is <0.25 EU/ml using water extraction method.
Hemolysis Testing
Hemolysis, ISO 10993-4
Material (Fluid Contact)
Medical grade Polysulfone (PS) meets USP 88 Class VI and FDA 21CFR177.1520.
Material Compliance
USP Biological Safety, Class VI for wetted parts, USP 88 plastics requirements and FDA 21CFR177.1520.
Sensor Isolation
Insoluble silicone dielectric gel isolates sensing element from process solution. The gel is a non toxic, nonallergenic elastomer system.
Sensor Microchip
EPROM-Stored sensor ID and calibration factor.
Sensor Type
Medical grade, silicone piezoresistive sensing element with on-chip temperature compensation
Temperature Range
0°C to 60°C
Tubing i.d.
1.9 mm (0.75 in)