+852-3069 6950
css@gugent.com.hk
 

Chromatography equipment and accessories

Column accessories, filters, sample loops, pumps, fraction collectors, and more equipment for chromatography systems.


Catalog No. Product Net Price
CYT28922770 Decanting Device 50 289.5 
Add to Cart
  • Material
  • Polyetheretherketone(PEEK)\nStainless steel
  • Wetted Part
  • Yes
  • Guidance
  • For Media wand 50\n\nTo be used with \n5 and 10 L media \ncontainers
CYT28922771 Decanting Device 100 312 
Add to Cart
  • Material
  • Polyetheretherketone(PEEK)\nStainless steel
  • Wetted Part
  • Yes
  • Guidance
  • For Media wand 50\n\nTo be used with \n5 and 10 L media \ncontainers
CYT28923074 Tubing 2 m, 50 mm TC, i.d. 22 mm, PTFE 1305 
Add to Cart
  • Pack size
  • Length = 2 m
  • Material
  • Polytetrafluoroethylene (PTFE)
  • Wetted Part
  • Yes
  • Guidance
  • This wetted part has been approved to biological reactivity testing in vivo, USP class VI.
  • Length
  • 2 m
CYT28922773 Cleaning-in-Place Manifold for Media Handling Unit 2205 
Add to Cart
  • Material
  • Polypropylene (PP)
  • Wetted Part
  • Yes
  • Guidance
  • Wetted parts have been approved to biological reactivity testing in vivo, USP class VI.
CYT29011360 UV Monitor U9-L 7248 
Add to Cart
  • Pack size
  • 1
  • Wetted Part
  • No
CYT28979439 Sensor Assembly, SciLog temperature sensor 463.5 
Add to Cart
  • Autoclavable
  • Yes
  • Connections
  • ReadyMate
  • Certificate of Analysis
  • Yes
  • Sterility
  • Each component is sterile for all fluid-contact surfaces (per AAMI TIR 33:2005 and the principles of ISO/AAMI/ASTM 11137-1:2006).
  • Animal Free Compliance
  • Animal-free Origin for wetted parts per EMEA/410/01 (alternatively-manufacturing under denaturing conditions).
  • Compatibility
  • Compatible with most sanitizing agents such as NaOH, hypochlorite, for flow cell sanitization.
  • Endotoxin
  • For process fluid contact surfaces, endotoxin level is <0.25 EU/ml using water extraction method.
  • Hemolysis Testing
  • Hemolysis, ISO 10993-4
  • Material (Fluid Contact)
  • Medical grade Polysulfone (PS) meets USP 88 Class VI and FDA 21CFR177.1520.
  • Material Compliance
  • USP Biological Safety, Class VI for wetted parts, USP 88 plastics requirements and FDA 21CFR177.1520.
  • Sensor Isolation
  • Insoluble silicone dielectric gel isolates sensing element from process solution. The gel is a non toxic, nonallergenic elastomer system.
  • Sensor Microchip
  • EPROM-Stored sensor ID and calibration factor.
  • Sensor Type
  • Medical grade, silicone piezoresistive sensing element with on-chip temperature compensation
  • Temperature Range
  • 0°C to 60°C
  • Tubing i.d.
  • 1.9 mm (0.75 in)
CYT28956500 Air Sensor L9-1.5 mm 2848.5 
Add to Cart
  • Dimensions
  • H x W x D: 660 x 860 x 710
  • Operating Temperature
  • 4°C-35°C
  • Wetted Materials
  • Polyetheretherketone (PEEK)
  • Wetted Part
  • Yes
  • Guidance
  • To connect the air sensor use:\nTubing i.d. 1.6 mm o.d. 1/8\
  • Power consumption
  • 800 VA
  • Relative humidity
  • 20%-95% (non condensing)
  • Diameter
  • 1.5 mm
CYT29274543 Air sensor 1 L9, Snap 4.8 mm 3928.5 
Add to Cart
  • Dimensions
  • H x W x D: 660 x 860 x 710
  • Operating Temperature
  • 4°C-35°C
  • Wetted Materials
  • Polyetheretherketone (PEEK)
  • Wetted Part
  • Yes
  • Guidance
  • To connect the air sensor use:\nTubing i.d. 1.6 mm o.d. 1/8\
  • Power consumption
  • 800 VA
  • Relative humidity
  • 20%-95% (non condensing)
  • Diameter
  • 1.5 mm
CYT29274545 Air sensor 3 L9, Snap 4.8 mm 3928.5 
Add to Cart
  • Dimensions
  • H x W x D: 660 x 860 x 710
  • Operating Temperature
  • 4°C-35°C
  • Wetted Materials
  • Polyetheretherketone (PEEK)
  • Wetted Part
  • Yes
  • Guidance
  • To connect the air sensor use:\nTubing i.d. 1.6 mm o.d. 1/8\
  • Power consumption
  • 800 VA
  • Relative humidity
  • 20%-95% (non condensing)
  • Diameter
  • 1.5 mm
CYT29274546 Air sensor 4 L9, Snap 4.8 mm 3928.5 
Add to Cart
  • Dimensions
  • H x W x D: 660 x 860 x 710
  • Operating Temperature
  • 4°C-35°C
  • Wetted Materials
  • Polyetheretherketone (PEEK)
  • Wetted Part
  • Yes
  • Guidance
  • To connect the air sensor use:\nTubing i.d. 1.6 mm o.d. 1/8\
  • Power consumption
  • 800 VA
  • Relative humidity
  • 20%-95% (non condensing)
  • Diameter
  • 1.5 mm