CYT17371530 |
PreDictor Capto adhere ImpRes, 6
|
1488
|
Add to Cart
|
- Dimensions
- 127.8 x 85.5 x 30.6 mm
- Material
- Polypropylene (PP) and Polyethylene (PE)
- Chromatography resin
- Capto adhere ImpRes
- Resin suspensions in total volumes
- 200 μl for 2 μl sedimented resin/well\n500 μl for 6, 20, and 50 μl sedimented resin/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented resin/well\n– 200 μl for 20 μl sedimented resin/well\n– 500 μl for 8 μl sedimented resin/well\n– 375 μl for 6 μl sedimented resin/well\n– 250 μl for 4 μl sedimented resin/well\n– 125 μl for 2 μl sedimented resin/well
- Well Volume
- 800
|
|
CYT17371531 |
PreDictor Capto adhere ImpRes, 20
|
1488
|
Add to Cart
|
- Dimensions
- 127.8 x 85.5 x 30.6 mm
- Material
- Polypropylene (PP) and Polyethylene (PE)
- Chromatography resin
- Capto adhere ImpRes
- Resin suspensions in total volumes
- 200 μl for 2 μl sedimented resin/well\n500 μl for 6, 20, and 50 μl sedimented resin/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented resin/well\n– 200 μl for 20 μl sedimented resin/well\n– 500 μl for 8 μl sedimented resin/well\n– 375 μl for 6 μl sedimented resin/well\n– 250 μl for 4 μl sedimented resin/well\n– 125 μl for 2 μl sedimented resin/well
- Well Volume
- 800
|
|
CYT28992314 |
PreDictor Phenyl Sepharose 6 Fast Flow (high sub), 6 μl
|
1518
|
Add to Cart
|
- Chromatography technique
- Hydrophobic Interaction Chromatography
- Dimensions
- 127.8 x 85.5 x 30.6 mm
- Material
- Polypropylene (PP) and Polyethylene (PE)
- Storage
- 4 to 30°C, 20% Ethanol
- Chromatography resin
- Phenyl Sepharose 6 Fast Flow
- Resin suspensions in total volumes
- 200 μl for 2 μl sedimented resin/well\n500 μl for 6, 20, and 50 μl sedimented resin/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented resin/well\n– 200 μl for 20 μl sedimented resin/well\n– 500 μl for 8 μl sedimented resin/well\n– 375 μl for 6 μl sedimented resin/well\n– 250 μl for 4 μl sedimented resin/well\n– 125 μl for 2 μl sedimented resin/well
- Centrifugation force recommended
- 100 x g (Sample Dependent)-500 x g (Sample Dependent)
- Operating temp. max.
- 30°C
- Operating temp. min.
- 4°C
- Well Volume
- 800
|
|
CYT28992374 |
PreDictor Phenyl Sepharose 6 Fast Flow (high sub), 50 μl
|
1518
|
Add to Cart
|
- Chromatography technique
- Hydrophobic Interaction Chromatography
- Dimensions
- 127.8 x 85.5 x 30.6 mm
- Material
- Polypropylene (PP) and Polyethylene (PE)
- Storage
- 4 to 30°C, 20% Ethanol
- Chromatography resin
- Phenyl Sepharose 6 Fast Flow
- Resin suspensions in total volumes
- 200 μl for 2 μl sedimented resin/well\n500 μl for 6, 20, and 50 μl sedimented resin/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented resin/well\n– 200 μl for 20 μl sedimented resin/well\n– 500 μl for 8 μl sedimented resin/well\n– 375 μl for 6 μl sedimented resin/well\n– 250 μl for 4 μl sedimented resin/well\n– 125 μl for 2 μl sedimented resin/well
- Centrifugation force recommended
- 100 x g (Sample Dependent)-500 x g (Sample Dependent)
- Operating temp. max.
- 30°C
- Operating temp. min.
- 4°C
- Well Volume
- 800
|
|
CYT28943288 |
PreDictor AIEX Screening, 2
|
498
|
Add to Cart
|
- Chromatography technique
- Ion Exchange Chromatography
- Dimensions
- 127.8 x 85.5 x 30.6 mm
- Material
- Polypropylene (PP) and Polyethylene (PE)
- Storage
- 4 to 30°C, 20% Ethanol
- Chromatography resin
- Capto Q 2 μl, Capto DEAE 2 μl, Q Sepharose Fast Flow 6 μl and Capto adhere 6 μl
- Resin suspensions in total volumes
- 200 μl for 2 μl sedimented medium/well\n500 μl for 6, 20, and 50 μl sedimented medium/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented medium/well\n– 200 μl for 20 μl sedimented medium/well\n– 500 μl for 8 μl sedimented medium/well\n– 375 μl for 6 μl sedimented medium/well\n– 250 μl for 4 μl sedimented medium/well\n– 125 μl for 2 μl sedimented medium/well
- Centrifugation force recommended
- 100 x g (Sample Dependent)-500 x g (Sample Dependent)
- Operating temp. max.
- 30°C
- Operating temp. min.
- 4°C
- Well Volume
- 800
|
|
CYT28943289 |
PreDictor AIEX Screening, 20 μl
|
498
|
Add to Cart
|
- Chromatography technique
- Ion Exchange Chromatography
- Dimensions
- 127.8 x 85.5 x 30.6 mm
- Material
- Polypropylene (PP) and Polyethylene (PE)
- Storage
- 4 to 30°C, 20% Ethanol
- Chromatography resin
- Capto Q 2 μl, Capto DEAE 2 μl, Q Sepharose Fast Flow 6 μl and Capto adhere 6 μl
- Resin suspensions in total volumes
- 200 μl for 2 μl sedimented medium/well\n500 μl for 6, 20, and 50 μl sedimented medium/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented medium/well\n– 200 μl for 20 μl sedimented medium/well\n– 500 μl for 8 μl sedimented medium/well\n– 375 μl for 6 μl sedimented medium/well\n– 250 μl for 4 μl sedimented medium/well\n– 125 μl for 2 μl sedimented medium/well
- Centrifugation force recommended
- 100 x g (Sample Dependent)-500 x g (Sample Dependent)
- Operating temp. max.
- 30°C
- Operating temp. min.
- 4°C
- Well Volume
- 800
|
|
CYT28943290 |
PreDictor CIEX Screening, 2
|
498
|
Add to Cart
|
- Chromatography technique
- Ion Exchange Chromatography
- Dimensions
- 127.8 x 85.5 x 30.6 mm
- Material
- Polypropylene (PP) and Polyethylene (PE)
- Storage
- 4 to 30°C, 20% Ethanol + 0.2 M Sodium Acetate
- Resin suspensions in total volumes
- 200 μl for 2 μl sedimented resin/well\n500 μl for 6, 20, and 50 μl sedimented resin/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented resin/well\n– 200 μl for 20 μl sedimented resin/well\n– 500 μl for 8 μl sedimented resin/well\n– 375 μl for 6 μl sedimented resin/well\n– 250 μl for 4 μl sedimented resin/well\n– 125 μl for 2 μl sedimented resin/well
- Centrifugation force recommended
- 100 x g (Sample Dependent)-500 x g (Sample Dependent)
- Operating temp. max.
- 30°C
- Operating temp. min.
- 4°C
- Well Volume
- 800
|
|
CYT28943291 |
PreDictor CIEX Screening, 20 μl
|
498
|
Add to Cart
|
- Chromatography technique
- Ion Exchange Chromatography
- Dimensions
- 127.8 x 85.5 x 30.6 mm
- Material
- Polypropylene (PP) and Polyethylene (PE)
- Storage
- 4 to 30°C, 20% Ethanol + 0.2 M Sodium Acetate
- Resin suspensions in total volumes
- 200 μl for 2 μl sedimented resin/well\n500 μl for 6, 20, and 50 μl sedimented resin/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented resin/well\n– 200 μl for 20 μl sedimented resin/well\n– 500 μl for 8 μl sedimented resin/well\n– 375 μl for 6 μl sedimented resin/well\n– 250 μl for 4 μl sedimented resin/well\n– 125 μl for 2 μl sedimented resin/well
- Centrifugation force recommended
- 100 x g (Sample Dependent)-500 x g (Sample Dependent)
- Operating temp. max.
- 30°C
- Operating temp. min.
- 4°C
- Well Volume
- 800
|
|
CYT28992392 |
PreDictor HIC Screening High Hydrophobicity, 6 μl
|
499.5
|
Add to Cart
|
- Chromatography technique
- Hydrophobic Interaction Chromatography
- Dimensions
- 127.8 x 85.5 x 30.6 mm
- Material
- Polypropylene (PP) and Polyethylene (PE)
- Storage
- 4 to 30°C, 20% Ethanol
- Chromatography resin
- Phenyl Sepharose 6 Fast Flow (low sub) 6 μl, Capto Butyl 6 μl, Phenyl Sepharose Fast Flow (high sub) 6 μl and Capto Phenyl (high sub) 6 μl
- Resin suspensions in total volumes
- 200 μl for 2 μl sedimented resin/well\n500 μl for 6, 20, and 50 μl sedimented resin/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented resin/well\n– 200 μl for 20 μl sedimented resin/well\n– 500 μl for 8 μl sedimented resin/well\n– 375 μl for 6 μl sedimented resin/well\n– 250 μl for 4 μl sedimented resin/well\n– 125 μl for 2 μl sedimented resin/well
- Centrifugation force recommended
- 100 x g (Sample Dependent)-500 x g (Sample Dependent)
- Operating temp. max.
- 30°C
- Operating temp. min.
- 4°C
- Well Volume
- 800
|
|
CYT28992395 |
PreDictor HIC Screening Low Hydrophobicity, 6 μl
|
499.5
|
Add to Cart
|
- Chromatography technique
- Hydrophobic Interaction Chromatography
- Dimensions
- 127.8 x 85.5 x 30.6 mm
- Material
- Polypropylene (PP) and Polyethylene (PE)
- Storage
- 4 to 30°C, 20% Ethanol
- Chromatography resin
- Butyl-S Sepharose 6 Fast Flow 6 μl, Octyl Sepharose 4 Fast Flow 6 μl, Butyl Sepharose 4 Fast Flow 6 μl and Capto Octyl 6 μl
- Resin suspensions in total volumes
- 200 μl for 2 μl sedimented resin/well\n500 μl for 6, 20, and 50 μl sedimented resin/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented resin/well\n– 200 μl for 20 μl sedimented resin/well\n– 500 μl for 8 μl sedimented resin/well\n– 375 μl for 6 μl sedimented resin/well\n– 250 μl for 4 μl sedimented resin/well\n– 125 μl for 2 μl sedimented resin/well
- Centrifugation force recommended
- 100 x g (Sample Dependent)-500 x g (Sample Dependent)
- Operating temp. max.
- 30°C
- Operating temp. min.
- 4°C
- Well Volume
- 800
|