+852-3069 6950
sales@gugent.com.hk
 

Liquid preparation and management

Easy to connect single-use components for robust mixing, easy handling, and convenient storage of bioprocess liquids.


Catalog No. Product Net Price
CYT17371530 PreDictor Capto adhere ImpRes, 6 992 
Add to Cart
  • Dimensions
  • 127.8 x 85.5 x 30.6 mm
  • Material
  • Polypropylene (PP) and Polyethylene (PE)
  • Chromatography resin
  • Capto adhere ImpRes
  • Resin suspensions in total volumes
  • 200 μl for 2 μl sedimented resin/well\n500 μl for 6, 20, and 50 μl sedimented resin/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented resin/well\n– 200 μl for 20 μl sedimented resin/well\n– 500 μl for 8 μl sedimented resin/well\n– 375 μl for 6 μl sedimented resin/well\n– 250 μl for 4 μl sedimented resin/well\n– 125 μl for 2 μl sedimented resin/well
  • Well Volume
  • 800
CYT17371531 PreDictor Capto adhere ImpRes, 20 992 
Add to Cart
  • Dimensions
  • 127.8 x 85.5 x 30.6 mm
  • Material
  • Polypropylene (PP) and Polyethylene (PE)
  • Chromatography resin
  • Capto adhere ImpRes
  • Resin suspensions in total volumes
  • 200 μl for 2 μl sedimented resin/well\n500 μl for 6, 20, and 50 μl sedimented resin/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented resin/well\n– 200 μl for 20 μl sedimented resin/well\n– 500 μl for 8 μl sedimented resin/well\n– 375 μl for 6 μl sedimented resin/well\n– 250 μl for 4 μl sedimented resin/well\n– 125 μl for 2 μl sedimented resin/well
  • Well Volume
  • 800
CYT28992314 PreDictor Phenyl Sepharose 6 Fast Flow (high sub), 6 μl 1012 
Add to Cart
  • Chromatography technique
  • Hydrophobic Interaction Chromatography
  • Dimensions
  • 127.8 x 85.5 x 30.6 mm
  • Material
  • Polypropylene (PP) and Polyethylene (PE)
  • Storage
  • 4 to 30°C, 20% Ethanol
  • Chromatography resin
  • Phenyl Sepharose 6 Fast Flow
  • Resin suspensions in total volumes
  • 200 μl for 2 μl sedimented resin/well\n500 μl for 6, 20, and 50 μl sedimented resin/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented resin/well\n– 200 μl for 20 μl sedimented resin/well\n– 500 μl for 8 μl sedimented resin/well\n– 375 μl for 6 μl sedimented resin/well\n– 250 μl for 4 μl sedimented resin/well\n– 125 μl for 2 μl sedimented resin/well
  • Centrifugation force recommended
  • 100 x g (Sample Dependent)-500 x g (Sample Dependent)
  • Operating temp. max.
  • 30°C
  • Operating temp. min.
  • 4°C
  • Well Volume
  • 800
CYT28992374 PreDictor Phenyl Sepharose 6 Fast Flow (high sub), 50 μl 1012 
Add to Cart
  • Chromatography technique
  • Hydrophobic Interaction Chromatography
  • Dimensions
  • 127.8 x 85.5 x 30.6 mm
  • Material
  • Polypropylene (PP) and Polyethylene (PE)
  • Storage
  • 4 to 30°C, 20% Ethanol
  • Chromatography resin
  • Phenyl Sepharose 6 Fast Flow
  • Resin suspensions in total volumes
  • 200 μl for 2 μl sedimented resin/well\n500 μl for 6, 20, and 50 μl sedimented resin/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented resin/well\n– 200 μl for 20 μl sedimented resin/well\n– 500 μl for 8 μl sedimented resin/well\n– 375 μl for 6 μl sedimented resin/well\n– 250 μl for 4 μl sedimented resin/well\n– 125 μl for 2 μl sedimented resin/well
  • Centrifugation force recommended
  • 100 x g (Sample Dependent)-500 x g (Sample Dependent)
  • Operating temp. max.
  • 30°C
  • Operating temp. min.
  • 4°C
  • Well Volume
  • 800
CYT28943288 PreDictor AIEX Screening, 2 332 
Add to Cart
  • Chromatography technique
  • Ion Exchange Chromatography
  • Dimensions
  • 127.8 x 85.5 x 30.6 mm
  • Material
  • Polypropylene (PP) and Polyethylene (PE)
  • Storage
  • 4 to 30°C, 20% Ethanol
  • Chromatography resin
  • Capto Q 2 μl, Capto DEAE 2 μl, Q Sepharose Fast Flow 6 μl and Capto adhere 6 μl
  • Resin suspensions in total volumes
  • 200 μl for 2 μl sedimented medium/well\n500 μl for 6, 20, and 50 μl sedimented medium/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented medium/well\n– 200 μl for 20 μl sedimented medium/well\n– 500 μl for 8 μl sedimented medium/well\n– 375 μl for 6 μl sedimented medium/well\n– 250 μl for 4 μl sedimented medium/well\n– 125 μl for 2 μl sedimented medium/well
  • Centrifugation force recommended
  • 100 x g (Sample Dependent)-500 x g (Sample Dependent)
  • Operating temp. max.
  • 30°C
  • Operating temp. min.
  • 4°C
  • Well Volume
  • 800
CYT28943289 PreDictor AIEX Screening, 20 μl 332 
Add to Cart
  • Chromatography technique
  • Ion Exchange Chromatography
  • Dimensions
  • 127.8 x 85.5 x 30.6 mm
  • Material
  • Polypropylene (PP) and Polyethylene (PE)
  • Storage
  • 4 to 30°C, 20% Ethanol
  • Chromatography resin
  • Capto Q 2 μl, Capto DEAE 2 μl, Q Sepharose Fast Flow 6 μl and Capto adhere 6 μl
  • Resin suspensions in total volumes
  • 200 μl for 2 μl sedimented medium/well\n500 μl for 6, 20, and 50 μl sedimented medium/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented medium/well\n– 200 μl for 20 μl sedimented medium/well\n– 500 μl for 8 μl sedimented medium/well\n– 375 μl for 6 μl sedimented medium/well\n– 250 μl for 4 μl sedimented medium/well\n– 125 μl for 2 μl sedimented medium/well
  • Centrifugation force recommended
  • 100 x g (Sample Dependent)-500 x g (Sample Dependent)
  • Operating temp. max.
  • 30°C
  • Operating temp. min.
  • 4°C
  • Well Volume
  • 800
CYT28943290 PreDictor CIEX Screening, 2 332 
Add to Cart
  • Chromatography technique
  • Ion Exchange Chromatography
  • Dimensions
  • 127.8 x 85.5 x 30.6 mm
  • Material
  • Polypropylene (PP) and Polyethylene (PE)
  • Storage
  • 4 to 30°C, 20% Ethanol + 0.2 M Sodium Acetate
  • Resin suspensions in total volumes
  • 200 μl for 2 μl sedimented resin/well\n500 μl for 6, 20, and 50 μl sedimented resin/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented resin/well\n– 200 μl for 20 μl sedimented resin/well\n– 500 μl for 8 μl sedimented resin/well\n– 375 μl for 6 μl sedimented resin/well\n– 250 μl for 4 μl sedimented resin/well\n– 125 μl for 2 μl sedimented resin/well
  • Centrifugation force recommended
  • 100 x g (Sample Dependent)-500 x g (Sample Dependent)
  • Operating temp. max.
  • 30°C
  • Operating temp. min.
  • 4°C
  • Well Volume
  • 800
CYT28943291 PreDictor CIEX Screening, 20 μl 332 
Add to Cart
  • Chromatography technique
  • Ion Exchange Chromatography
  • Dimensions
  • 127.8 x 85.5 x 30.6 mm
  • Material
  • Polypropylene (PP) and Polyethylene (PE)
  • Storage
  • 4 to 30°C, 20% Ethanol + 0.2 M Sodium Acetate
  • Resin suspensions in total volumes
  • 200 μl for 2 μl sedimented resin/well\n500 μl for 6, 20, and 50 μl sedimented resin/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented resin/well\n– 200 μl for 20 μl sedimented resin/well\n– 500 μl for 8 μl sedimented resin/well\n– 375 μl for 6 μl sedimented resin/well\n– 250 μl for 4 μl sedimented resin/well\n– 125 μl for 2 μl sedimented resin/well
  • Centrifugation force recommended
  • 100 x g (Sample Dependent)-500 x g (Sample Dependent)
  • Operating temp. max.
  • 30°C
  • Operating temp. min.
  • 4°C
  • Well Volume
  • 800
CYT28992392 PreDictor HIC Screening High Hydrophobicity, 6 μl 333 
Add to Cart
  • Chromatography technique
  • Hydrophobic Interaction Chromatography
  • Dimensions
  • 127.8 x 85.5 x 30.6 mm
  • Material
  • Polypropylene (PP) and Polyethylene (PE)
  • Storage
  • 4 to 30°C, 20% Ethanol
  • Chromatography resin
  • Phenyl Sepharose 6 Fast Flow (low sub) 6 μl, Capto Butyl 6 μl, Phenyl Sepharose Fast Flow (high sub) 6 μl and Capto Phenyl (high sub) 6 μl
  • Resin suspensions in total volumes
  • 200 μl for 2 μl sedimented resin/well\n500 μl for 6, 20, and 50 μl sedimented resin/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented resin/well\n– 200 μl for 20 μl sedimented resin/well\n– 500 μl for 8 μl sedimented resin/well\n– 375 μl for 6 μl sedimented resin/well\n– 250 μl for 4 μl sedimented resin/well\n– 125 μl for 2 μl sedimented resin/well
  • Centrifugation force recommended
  • 100 x g (Sample Dependent)-500 x g (Sample Dependent)
  • Operating temp. max.
  • 30°C
  • Operating temp. min.
  • 4°C
  • Well Volume
  • 800
CYT28992395 PreDictor HIC Screening Low Hydrophobicity, 6 μl 333 
Add to Cart
  • Chromatography technique
  • Hydrophobic Interaction Chromatography
  • Dimensions
  • 127.8 x 85.5 x 30.6 mm
  • Material
  • Polypropylene (PP) and Polyethylene (PE)
  • Storage
  • 4 to 30°C, 20% Ethanol
  • Chromatography resin
  • Butyl-S Sepharose 6 Fast Flow 6 μl, Octyl Sepharose 4 Fast Flow 6 μl, Butyl Sepharose 4 Fast Flow 6 μl and Capto Octyl 6 μl
  • Resin suspensions in total volumes
  • 200 μl for 2 μl sedimented resin/well\n500 μl for 6, 20, and 50 μl sedimented resin/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented resin/well\n– 200 μl for 20 μl sedimented resin/well\n– 500 μl for 8 μl sedimented resin/well\n– 375 μl for 6 μl sedimented resin/well\n– 250 μl for 4 μl sedimented resin/well\n– 125 μl for 2 μl sedimented resin/well
  • Centrifugation force recommended
  • 100 x g (Sample Dependent)-500 x g (Sample Dependent)
  • Operating temp. max.
  • 30°C
  • Operating temp. min.
  • 4°C
  • Well Volume
  • 800