Modes of Operation Supported: External Water Mode for Eluents Containing up to 40% Solvent; Chemical Regeneration Mode for Eluents Containing up to 100% Solvent; Recycled Eluent Mode for Aqueous Eluents Without Solvent; MPIC (Mobile Phase Ion Chromatography) Mode for Ion-Pairing Eluents
Unit Size
Each
Type
Anion Electrolytically Regenerated Suppressor
Description
Dionex AERS 500e Anion Electrolytically Regenerated Suppressor for External Water Mode (4 mm), consumables monitoring disabled
Flow Rate
Maximum Eluent Flow Rate: 3 mL/min
Solvents
Recommended Backpressure: 30 to 150 psi
Operation
Designed with high capacity, low noise, high backpressure resiliency, and fast startup.
Pressure
Recommended Backpressure: 30 to 150 psi
Amperage
500 mA
Temperature Range
Operational Temperature Range: 15°C to 40°C When installed outside the heated column enclosure, suppressors can support applications up to 60°C Shipping Temperature Range: 0°C to 70°C Short-term only; do not store or operate suppressors above 40°C for extended lengths of time.
Modes of Operation Supported: External Water Mode for Eluents Containing up to 40% Solvent; Chemical Regeneration Mode for Eluents Containing up to 100% Solvent; Recycled Eluent Mode for Aqueous Eluents Without Solvent; MPIC (Mobile Phase Ion Chromatography) Mode for Ion-Pairing Eluents
Unit Size
Each
Type
Anion Electrolytically Regenerated Suppressor
Description
Dionex AERS 500e Anion Electrolytically Regenerated Suppressor for External Water Mode (2 mm), consumables monitoring disabled
Flow Rate
Maximum Eluent Flow Rate: 0.75 mL/min
Solvents
External Water Mode Up to 40%Methanol, Ethanol, Acetonitrile, Isopropanol
Operation
Designed with high capacity, low noise, high backpressure resiliency, and fast startup.
Pressure
Recommended Backpressure: 30 to 150 psi
Amperage
150 mA
Temperature Range
Operational Temperature Range: 15°C to 40°C When installed outside the heated column enclosure, suppressors can support applications up to 60°C Shipping Temperature Range: 0°C to 70°C Short-term only; do not store or operate suppressors above 40°C for extended lengths of time.
Modes of Operation Supported: External Water Mode for Eluents Containing up to 40% Solvent; Chemical Regeneration Mode for Eluents Containing up to 100% Solvent; Recycled Eluent Mode for Aqueous Eluents Without Solvent; MPIC (Mobile Phase Ion Chromatography) Mode for Ion-Pairing Eluents
Unit Size
Each
Type
Cation Electrolytically Regenerated Suppressor
Description
Dionex CERS 500e Cation Electrolytically Regenerated Suppressor for External Water Mode (4 mm), consumables monitoring disabled
Flow Rate
Maximum Eluent Flow Rate: 3 mL/min
Solvents
External Water Mode Up to 40%Methanol, Ethanol, Acetonitrile, Isopropanol
Operation
Designed with high capacity, low noise, high backpressure resiliency, and fast startup.
Pressure
Recommended Backpressure: 30 to 150 psi
Amperage
300 mA
Temperature Range
Operational Temperature Range: 15°C to 40°C When installed outside the heated column enclosure, suppressors can support applications up to 60°C Shipping Temperature Range: 0°C to 70°C Short-term only; do not store or operate suppressors above 40°C for extended lengths of time.
Modes of Operation Supported: External Water Mode for Eluents Containing up to 40% Solvent; Chemical Regeneration Mode for Eluents Containing up to 100% Solvent; Recycled Eluent Mode for Aqueous Eluents Without Solvent; MPIC (Mobile Phase Ion Chromatography) Mode for Ion-Pairing Eluents
Unit Size
Each
Type
Cation Electrolytically Regenerated Suppressor
Description
Dionex CERS 500e Cation Electrolytically Regenerated Suppressor for External Water Mode (2 mm), consumables monitoring disabled
Flow Rate
Maximum Eluent Flow Rate: 0.75 mL/min
Solvents
External Water Mode Up to 40%Methanol, Ethanol, Acetonitrile, Isopropanol
Operation
Designed with high capacity, low noise, high backpressure resiliency, and fast startup.
Pressure
Recommended Backpressure: 30 to 150 psi
Amperage
110 mA
Temperature Range
Operational Temperature Range: 15°C to 40°C When installed outside the heated column enclosure, suppressors can support applications up to 60°C Shipping Temperature Range: 0°C to 70°C Short-term only; do not store or operate suppressors above 40°C for extended lengths of time.
Our extensive inventory of replacement parts, accessories, software and consumables will keep your instruments and equipment performing at optimal levels in your laboratory.