Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Cartridge Code
Code 5 (2-222) O-rings and spear
Cartridge Nominal Length
10 in. (25 cm)
Catalogue Number
CCGL51TP1
Chemistry
Polyvinylidene Fluoride (PVDF)
Device Configuration
Cartridge
Device Material
Polypropylene
Device Size
10 in.
Diameter
6.9 cm (2.7 in.)
Filtration Area
0.69 m²
Flow Rate
45 L/min @ 1.2 bar ΔP
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 20 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
Length
10 in. (25 cm)
Material Package
Double Easy-Open bag
Material Size
1
Maximum Differential Pressure, bar (psid)
Forward: 5.5 bar (80 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 135 °C. Reverse: 3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
Forward - 5.5 bar (80 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 135 °C; Reverse - 3.5 bar (50 psi) @ 25 °C
Media
Charged Durapore®
Non-Fiber Releasing
This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥500 mL
Pore Size
0.22 µm
Seal Material
Silicone (SI)
Sterility
Other
Sterilization
10 SIP cycles of 30 min @ 135 °C
Support Material
Polypropylene
Trade Name
Durapore®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.