- 
				    
					Bacterial Endotoxins Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test 
- 
				    
					Bacterial Retention Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology. 
- 
				    
					Cartridge Nominal Length 10 in. (25 cm) 
- 
				    
					Catalogue Number KVEPA10TH1 
- 
				    
					Chemistry Polyethersulfone (PES) 
- 
				    
					Device Configuration Capsule 
- 
				    
					Device Material Polypropylene 
- 
				    
					Device Size 10 in. 
- 
				    
					Diameter 10.7 cm (4.2 in.) 
- 
				    
					European Pressure Equipment Directive EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark. 
- 
				    
					Filtration Area 0.6 m² 
- 
				    
					Good Manufacturing Practices These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices. 
- 
				    
					Housing Material Polypropylene (PP) 
- 
				    
					Indirect Food Additive All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. 
- 
				    
					Inlet Connection Sanitary Flange 
- 
				    
					Inlet Connection Diameter 1-1/2 in. 
- 
				    
					Inlet to Outlet Width 33.5 cm (13.2 in.) 
- 
				    
					Length 10 in. (25 cm) 
- 
				    
					Material Package Double Easy-Open bag 
- 
				    
					Material Size 1 
- 
				    
					Maximum Differential Pressure 80 psi (5.5 bar) continuous100 psi (6.9 bar) intermittent 
- 
				    
					Maximum Differential Pressure, bar (psid) Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent 
- 
				    
					Maximum Inlet Pressure (psig) 80 psig 
- 
				    
					Maximum Inlet Pressure, bar (psi) 6.9 bar (100 psi) intermittent @ 23 °C; 5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C 
- 
				    
					Maximum Inlet Temperature 25 °C 
- 
				    
					Media Millipore Express® SHR 
- 
				    
					Non-Fiber Releasing This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6). 
- 
				    
					Outlet Connection Hose Barb 
- 
				    
					Outlet Connection Diameter 9/16 in. 
- 
				    
					Oxidizable Substances Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L 
- 
				    
					Pore Size 0.1 µm 
- 
				    
					Seal Material Silicone (SI) 
- 
				    
					Sterilization 3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable 
- 
				    
					Support Material Polypropylene 
- 
				    
					Trade Name Millipore Express® 
- 
				    
					USP Bacterial Endotoxins A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test. 
- 
				    
					Vent Cap Material Polypropylene (PP) 
- 
				    
					Wettability Hydrophilic 
- 
				    
					Width 33.5 cm (13.2 in.)