4 weeks
AB Sciex LLC ABS019484
Tube 3 8 Inch OD x 5 16 Inch ID FEP TEFL
13 /Each
SHIMADZU CORPORATION 220-91625-08
Column, LC, Nexera UC Chiral CCA, 3 Micron, 3.0 x 150 mm
2131 /Each
Thermo Fisher Scientific Inc. THM-S310502A-HKK
HERMETIC SEAL 1 ASSEMBLY
424 /Each
Merck KGaA WP6210060
High Output Pump, 100 V/50–60 Hz
852 /Each
Thermo Fisher Scientific Inc. THM303347
Dionex™ CarboPac™ PA300-4µm Column, 4 µm, 2 × 50 mm
Special offer /Each
PerkinElmer Inc. N0770614
Cyclonic Spray Chamber Adapter for Optima 2x00/4x00/5x00/7x00 DV/8x00
187 /Each
Thermo Fisher Scientific Inc. THM-C4013-95W
8-425 Clear Screw Thread Vial w/graduation line & marking spot, Blue cap, Blue PTFE/Silicone septa, Pre-Slit
60 /Each
Thermo Fisher Scientific Inc. THM-R50193
Remel™ Calibrated Inoculating Loops
Merck KGaA SCGPS02RE
Steritop Threaded Bottle Top Filter
70 /Each
MACHEREY‑NAGEL MN761921.30
EC HPLC guard column (analytical), NUCLEODUR Sphinx RP, 3 µm, 4x3 mm
Merck KGaA MSSACCEPT0R
96 well Collection Plate
590 /Each
GL Sciences Inc. GLS5020-79089
Inertsil WP300 Diol Prep Column, 5 µm, 250 x 14 mm
2429 /Each
Pall Corporation HCG300FKD8H
Versalon Glass Fiber 18 micron (Beta 1000) Nitrile 8in 20.32cm (REPLACED BY HCG300FRD8Z)
65 /Each
SHIMADZU CORPORATION 346-60910-01
GROUND PACKING, WHITE, MS30
95 /Each
SHIMADZU CORPORATION 227-30212-01
Column, LC, Shim-pack GIST Phenyl, 3um, 3.0x20
476 /Each
Agilent Technologies AGIL123-1364
J&W DB-624 GC Column, 60 m, 0.32 mm, 1.80 µm, 7 inch cage. This is the most common GC column format compatible with Agilent 5890, 6890, 7820, 7890, 8860, and 8890 series GC systems and all non-Agilent GC systems with a similarly sized oven.
1150 /Each
Regis Technologies, Inc. REG1-880252-300
AZYP CDShell-RSP - 2.7 µm, 100Å, 10 cm x 2.1 mm ID
1485 /Each
Thermo Fisher Scientific Inc. THM-6151-0250PK
Nalgene™ Tubing T-Type Connectors
27 /Each
Agilent Technologies AGIL125-1364E
J&W DB-624 GC Column, 60 m, 0.53 mm, 3.00 µm, 5 inch cage
1255 /Each
Daicel Corporation DAIC83511
CHIRALPAK® IC, 3 μm, 4.0 × 10 mm
333.56 /Each
Agilent Technologies AGIL125-1364
J&W DB-624 GC Column, 60 m, 0.53 mm, 3.00 µm, 7 inch cage. This is the most common GC column format compatible with Agilent 5890, 6890, 7820, 7890, 8860, and 8890 series GC systems and all non-Agilent GC systems with a similarly sized oven.
1140 /Each
Agilent Technologies AGIL123-5563UI
J&W DB-5ms Ultra Inert GC Column, 60 m, 0.32 mm, 1.00 µm, 7 inch cage. This is the most common GC column format compatible with Agilent 5890, 6890, 7820, 7890, 8860, and 8890 series GC systems and all non-Agilent GC systems with a similarly sized oven.
1269 /Each
Merck KGaA CR05F2006
Polygard-CR Cartridge Filter 20 in. 5.0 µm Code F
439 /Each