MN732707
CHROMABOND Flash RS 330 SiOH cartridges, 15–40 µm, 330 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash RS
Column length
28.0 cm
Column inner diameter
59.8 mm
Column connection
Female Luer lock inlet and male Luer tip outlet
Filling material
Irregular, 15–40 µm
Hardware
Polypropylene (PP)
Filling quantity
330 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
15–40 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Non-removable
Typical flow rate
75–255 mL/min
pH stability
2.0–8.0
Pressure stability (max)
11 bar
Filter element material
Polyethylene (PE)
Scope of delivery
4x CHROMABOND Flash RS cartridges
Storage temperature
RT
MN732708
CHROMABOND Flash RS 800 SiOH cartridges, 15–40 µm, 800 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash RS
Column length
38.3 cm
Column inner diameter
78.2 mm
Column connection
Maxi Luer
Filling material
Irregular, 15–40 µm
Hardware
Polypropylene (PP)
Filling quantity
800 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
15–40 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Non-removable
Typical flow rate
100–300 mL/min
pH stability
2.0–8.0
Pressure stability (max)
7 bar
Filter element material
Polyethylene (PE)
Scope of delivery
2x CHROMABOND Flash RS cartridges
Storage temperature
RT
MN732709
CHROMABOND Flash RS 1600 SiOH cartridges, 15–40 µm, 1600 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash RS
Column length
43.2 cm
Column inner diameter
103.8 mm
Column connection
Maxi Luer
Filling material
Irregular, 15–40 µm
Hardware
Polypropylene (PP)
Filling quantity
1600 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
15–40 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Non-removable
Typical flow rate
200–500 mL/min
pH stability
2.0–8.0
Pressure stability (max)
7 bar
Filter element material
Polyethylene (PE)
Scope of delivery
2x CHROMABOND Flash RS cartridges
Storage temperature
RT
MN732808
CHROMABOND Flash RS 800 SiOH cartridges, 40–63 µm, 800 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash RS
Column length
38.3 cm
Column inner diameter
78.2 mm
Column connection
Maxi Luer
Filling material
Irregular, 40–63 µm
Hardware
Polypropylene (PP)
Filling quantity
800 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
40–63 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Non-removable
Typical flow rate
140–240 mL/min
pH stability
2.0–8.0
Pressure stability (max)
7 bar
Filter element material
Polyethylene (PE)
Scope of delivery
2x CHROMABOND Flash RS cartridges
Storage temperature
RT
MN732809
CHROMABOND Flash RS 1600 SiOH cartridges, 40–63 µm,1600 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash RS
Column length
43.2 cm
Column inner diameter
103.8 mm
Column connection
Maxi Luer
Filling material
Irregular, 40–63 µm
Hardware
Polypropylene (PP)
Filling quantity
1600 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
40–63 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Non-removable
Typical flow rate
190–250 mL/min
pH stability
2.0–8.0
Pressure stability (max)
7 bar
Filter element material
Polyethylene (PE)
Scope of delivery
2x CHROMABOND Flash RS cartridges
Storage temperature
RT
MN732850
CHROMABOND Flash RS 3000 SiOH cartridges, 40–63 µm, 3000 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash RS
Column length
51.0 cm
Column inner diameter
127.5 mm
Column connection
Maxi Luer
Filling material
Irregular, 40–63 µm
Hardware
Polypropylene (PP)
Filling quantity
3000 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
40–63 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Non-removable
Typical flow rate
240-390 mL/min
pH stability
2.0–8.0
Pressure stability (max)
7 bar
Filter element material
Polyethylene (PE)
Scope of delivery
1x CHROMABOND Flash RS cartridge
Storage temperature
RT
MN732460
CHROMABOND Flash RS 4 SPHERE SiOH cartridges, spherical, 25 µm, 4 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash RS
Column length
10.6 cm
Column inner diameter
12.4 mm
Column connection
Female Luer lock inlet and male Luer tip outlet
Filling material
Spherical, 25 µm
Hardware
Polypropylene (PP)
Filling quantity
4 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
25 µm
Pore size
50 Å
Particle shape
Spherical
Specific surface according to BET
700 m²/g
Removable closure
Non-removable
Typical flow rate
10–30 mL/min
pH stability
2.0–8.0
Pressure stability (max)
21 bar
Filter element material
Polyethylene (PE)
Scope of delivery
20x CHROMABOND Flash RS cartridges
Storage temperature
RT
MN732461
CHROMABOND Flash RS 15 SPHERE SiOH cartridges, spherical, 25 µm, 12 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash RS
Column length
12.5 cm
Column inner diameter
21.2 mm
Column connection
Female Luer lock inlet and male Luer tip outlet
Filling material
Spherical, 25 µm
Hardware
Polypropylene (PP)
Filling quantity
15 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
25 µm
Pore size
50 Å
Particle shape
Spherical
Specific surface according to BET
700 m²/g
Removable closure
Non-removable
Typical flow rate
20–45 mL/min
pH stability
2.0–8.0
Pressure stability (max)
21 bar
Filter element material
Polyethylene (PE)
Scope of delivery
20x CHROMABOND Flash RS cartridges
Storage temperature
RT
MN732462
CHROMABOND Flash RS 25 SPHERE SiOH cartridges, spherical, 25 µm, 25 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash RS
Column length
17.3 cm
Column inner diameter
21.2 mm
Column connection
Female Luer lock inlet and male Luer tip outlet
Filling material
Spherical, 25 µm
Hardware
Polypropylene (PP)
Filling quantity
25 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
25 µm
Pore size
50 Å
Particle shape
Spherical
Specific surface according to BET
700 m²/g
Removable closure
Non-removable
Typical flow rate
20–45 mL/min
pH stability
2.0–8.0
Pressure stability (max)
21 bar
Filter element material
Polyethylene (PE)
Scope of delivery
15x CHROMABOND Flash RS cartridges
Storage temperature
RT
MN732463
CHROMABOND Flash RS 40 SPHERE SiOH cartridges, spherical, 25 µm, 40 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash RS
Column length
17.6 cm
Column inner diameter
26.7 mm
Column connection
Female Luer lock inlet and male Luer tip outlet
Filling material
Spherical, 25 µm
Hardware
Polypropylene (PP)
Filling quantity
40 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
25 µm
Pore size
50 Å
Particle shape
Spherical
Specific surface according to BET
700 m²/g
Removable closure
Non-removable
Typical flow rate
25–55 mL/min
pH stability
2.0–8.0
Pressure stability (max)
21 bar
Filter element material
Polyethylene (PE)
Scope of delivery
15x CHROMABOND Flash RS cartridges
Storage temperature
RT