We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.
Overview of Non-Sterile Millex® Syringe Filters with Hydrophilic PTFE• Lowest extractables, optimizing background levels of sensitive analyses like UHPLC and LC-MS• Filtration of protein-containing solutions, and aqueous or organic solutions• Available in 0.20 µm and 0.45 µm pore sizes and three diameters to suit your application needsAvailable in Multiple Pack Sizes:SKU ending with NS (-------NS): 50 per packSKU ending with NL (-------NB): 100 per packSKU ending with NB (-------NB): 250 per packSKU ending with NK (-------NK): 1000 per packSLCRT13NL: 100 per pack. These syringe filters have a tube outletApplications: Sample Filtration Prior to UHPLC, HPLC and Mass Spec; Solvent Filtration; Clarification of Aqueous and Organic Solutions
Catalogue Number
SLLHH04NL
Chemistry
Hydrophilic Polytetrafluoroethylene (PTFE)
Color Code
Natural inlet/natural outlet
Device Material
HDPE
Filter Diameter (⌀)
4 mm
Filtration Area
0.1 cm²
Fitting Inlet
Female Luer-Lok®
Fitting Outlet
Male Luer slip, stepped
Height
19.7 mm
Hold-up Volume
10 µL
Housing Material
High-density polyethylene (HDPE)
Key Applications
Analytical Sample PrepSterilization of drugs or aqueous solutions administered intravenouslyUltra-low protein binding
Overview of Non-Sterile Millex® Syringe Filters with Hydrophilic PTFE• Lowest extractables, optimizing background levels of sensitive analyses like UHPLC and LC-MS• Filtration of protein-containing solutions, and aqueous or organic solutions• Available in 0.20 µm and 0.45 µm pore sizes and three diameters to suit your application needsAvailable in Multiple Pack Sizes:SKU ending with NS (-------NS): 50 per packSKU ending with NL (-------NB): 100 per packSKU ending with NB (-------NB): 250 per packSKU ending with NK (-------NK): 1000 per packSLCRT13NL: 100 per pack. These syringe filters have a tube outletApplications: Sample Filtration Prior to UHPLC, HPLC and Mass Spec; Solvent Filtration; Clarification of Aqueous and Organic Solutions
Catalogue Number
SLLGH04NK
Chemistry
Hydrophilic Polytetrafluoroethylene (PTFE)
Color Code
Natural inlet/natural outlet
Device Material
HDPE
Filter Diameter (⌀)
4 mm
Filtration Area
0.1 cm²
Fitting Inlet
Female Luer-Lok®
Fitting Outlet
Male Luer slip, stepped
Height
19.7 mm
Hold-up Volume
10 µL
Housing Material
High-density polyethylene (HDPE)
Key Applications
Analytical Sample PrepSterilization of drugs or aqueous solutions administered intravenouslyUltra-low protein binding
Overview of Non-Sterile Millex® Syringe Filters with Hydrophilic PTFE• Lowest extractables, optimizing background levels of sensitive analyses like UHPLC and LC-MS• Filtration of protein-containing solutions, and aqueous or organic solutions• Available in 0.20 µm and 0.45 µm pore sizes and three diameters to suit your application needsAvailable in Multiple Pack Sizes:SKU ending with NS (-------NS): 50 per packSKU ending with NL (-------NB): 100 per packSKU ending with NB (-------NB): 250 per packSKU ending with NK (-------NK): 1000 per packSLCRT13NL: 100 per pack. These syringe filters have a tube outletApplications: Sample Filtration Prior to UHPLC, HPLC and Mass Spec; Solvent Filtration; Clarification of Aqueous and Organic Solutions
Catalogue Number
SLLGH04NL
Chemistry
Hydrophilic Polytetrafluoroethylene (PTFE)
Color Code
Natural inlet/natural outlet
Device Material
HDPE
Filter Diameter (⌀)
4 mm
Filtration Area
0.1 cm²
Fitting Inlet
Female Luer-Lok®
Fitting Outlet
Male Luer slip, stepped
Height
19.7 mm
Hold-up Volume
10 µL
Housing Material
High-density polyethylene (HDPE)
Key Applications
Analytical Sample PrepSterilization of drugs or aqueous solutions administered intravenouslyUltra-low protein binding
25 MM KITS25 MM – XX1002500The glass microanalysis filter holder is designed for vacuum filtration of small-volume liquid samples for particulate or biological contamination analysis.This item is a kit composed of the following items:(Catalog Number, Description)XX1002514 - Funnel,15 mL, borosilcate glassXX1002503 - Spring Clamp, 25 mm, aluminumXX1002502 - Fritted Glass Base with stopper, 25 mmFeatures & Benefits:•Volume graduations clearly indicate sample volume •Filter support available in fritted glass or stainless steel Applications:Contamination Analysis (not for use with thick prefilters or flammable liquids)
Catalogue Number
XX1002500
Diameter
2.5 cm (0.98 in.)
Filter Diameter (⌀)
25 mm
Filtration Area
2.5 cm²
Fitting Inlet
Funnel
Fitting Outlet
No. 5 perforated silicone stopper mounts in standard 125 mL filtering flask
Funnel Capacity
15 mL
Height
15.2 cm (6 in.)
Material Size
1
Materials of Construction
Borosilicate glass funnel and base; fritted glass filter support; anodized aluminum spring clamp; silicone stopper
25 MM KITS25 MM – XX1002500The glass microanalysis filter holder is designed for vacuum filtration of small-volume liquid samples for particulate or biological contamination analysis.This item is a kit composed of the following items:(Catalog Number, Description)XX1002514 - Funnel,15 mL, borosilcate glassXX1002503 - Spring Clamp, 25 mm, aluminumXX1002502 - Fritted Glass Base with stopper, 25 mmFeatures & Benefits:•Volume graduations clearly indicate sample volume •Filter support available in fritted glass or stainless steel Applications:Contamination Analysis (not for use with thick prefilters or flammable liquids)
Catalogue Number
XX1002500
Diameter
2.5 cm (0.98 in.)
Filter Diameter (⌀)
25 mm
Filtration Area
2.5 cm²
Fitting Inlet
Funnel
Fitting Outlet
No. 5 perforated silicone stopper mounts in standard 125 mL filtering flask
Funnel Capacity
15 mL
Height
15.2 cm (6 in.)
Material Size
1
Materials of Construction
Borosilicate glass funnel and base; fritted glass filter support; anodized aluminum spring clamp; silicone stopper
ClinicalCosmeticsEnvironmentalFood and BeverageIndustrial QCPharmaceutical
Material Package
Individually sealed, with blue separator paper, sterile
Material Size
4 boxes of 150 filters
Overview
S-Pak Filters 0.8 µm 47 mm white gridded are made from mixed esters of cellulose and have been optimized for MF method microbiological analysis of water or other liquids
ClinicalCosmeticsEnvironmentalFood and BeverageIndustrial QCPharmaceutical
Material Package
Individually sealed, with blue separator paper, sterile
Material Size
4 boxes of 150 filters
Overview
S-Pak Filters 0.8 µm 47 mm white gridded are made from mixed esters of cellulose and have been optimized for MF method microbiological analysis of water or other liquids
ClinicalCosmeticsEnvironmentalFood and BeverageIndustrial QCPharmaceutical
Material Package
Individually sealed, with blue separator paper, sterile
Material Size
4 boxes of 150 filters
Overview
S-Pak Filters 0.8 µm 47 mm black gridded are made from mixed esters of cellulose and have been optimized for MF method microbiological analysis of water or other liquids
Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.
Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.