Catalog No. Product Net Price
CS40MS01L3 Clarisolve® 40 µm Depth Filters in µPod® Format, 23 cm2 (0.025 ft2) 304 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique (on filter media only)
  • Catalogue Number
  • CS40MS01L3
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • µPod
  • Device Material
  • Polypropylene
  • Filter Grade
  • 40MS
  • Filtration Area
  • 0.0023 m²
  • Height
  • 6.99 cm (2.75 in.)
  • Length
  • 9.07 cm (3.57 in.)
  • Material Size
  • 3
  • Materials of Construction
  • Polypropylene and Millistak+® media
  • Maximum Differential Pressure, bar (psid)
  • Maximum: 3.5 bar (50 psid) @ ≤ 40 °C; Forward: 2.1 bar (30 psid) @ 40 °C; Reverse: 1.0 bar (15 psid) @ 40 °C
  • Media
  • Toxicological Information Safety Information according to GHS Safety Information Product Usage Statements Storage and Shipping Information Packaging Information Material Size
  • Sterilization
  • 2 autoclave cycles of 60 minutes at 123 °C
  • Trade Name
  • Clarisolve®
  • Width
  • 4.98 cm (1.96 in.)
CS40MS01L3 Clarisolve® 40 µm Depth Filters in µPod® Format, 23 cm2 (0.025 ft2) 304 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique (on filter media only)
  • Catalogue Number
  • CS40MS01L3
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • µPod
  • Device Material
  • Polypropylene
  • Filter Grade
  • 40MS
  • Filtration Area
  • 0.0023 m²
  • Height
  • 6.99 cm (2.75 in.)
  • Length
  • 9.07 cm (3.57 in.)
  • Material Size
  • 3
  • Materials of Construction
  • Polypropylene and Millistak+® media
  • Maximum Differential Pressure, bar (psid)
  • Maximum: 3.5 bar (50 psid) @ ≤ 40 °C; Forward: 2.1 bar (30 psid) @ 40 °C; Reverse: 1.0 bar (15 psid) @ 40 °C
  • Media
  • Toxicological Information Safety Information according to GHS Safety Information Product Usage Statements Storage and Shipping Information Packaging Information Material Size
  • Sterilization
  • 2 autoclave cycles of 60 minutes at 123 °C
  • Trade Name
  • Clarisolve®
  • Width
  • 4.98 cm (1.96 in.)
CS40MS02H1 Clarisolve® 40 µm Lab Scale Depth Filters, 0.027 m2 (0.29 ft2) 304 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique (on filter media only)
  • Catalogue Number
  • CS40MS02H1
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • lab scale Pod
  • Device Material
  • Polypropylene
  • Filter Grade
  • 40MS
  • Filtration Area
  • 0.027 m²
  • Height
  • 14 cm (5.3 in.)
  • Length
  • 22 cm (8.5 in.)
  • Material Size
  • 1
  • Materials of Construction
  • Polypropylene and Millistak+® media
  • Maximum Differential Pressure, bar (psid)
  • Maximum: 2.1 bar (30 psid) @ 37 °C; Forward: 2.1 bar (30 psid) @ 4 ° or 37 °C; Reverse: 2.1 bar (30 psid) @ 37 °C
  • Media
  • Seal Material
  • Seal Material
  • Thermo Plastic Elastomer (TPE)
  • Sterilization
  • Integrity is maintained after 2 autoclave cycles of 60 minutes at 123 °C.
  • Trade Name
  • Clarisolve®
  • Width
  • 9.4 cm (3.7 in.)
CS60HX01H1 Clarisolve® 60 µm Lab Scale Depth Filters, 0.014 m2 (0.15 ft2) 304 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique (on filter media only)
  • Catalogue Number
  • CS60HX01H1
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • lab scale Pod
  • Device Material
  • Polypropylene
  • Filter Grade
  • 60HX
  • Filtration Area
  • 0.014 m²
  • Height
  • 14 cm (5.3 in.)
  • Length
  • 22 cm (8.5 in.)
  • Material Size
  • 1
  • Materials of Construction
  • Polypropylene (PP)
  • Maximum Differential Pressure, bar (psid)
  • Maximum: 2.1 bar (30 psid) @ 37 °C; Forward: 2.1 bar (30 psid) @ 4 ° or 37 °C; Reverse: 2.1 bar (30 psid) @ 37 °C
  • Seal Material
  • Thermo Plastic Elastomer (TPE)
  • Sterilization
  • Integrity is maintained after 2 autoclave cycles of 60 minutes at 123 °C.
  • Trade Name
  • Clarisolve®
  • Width
  • 7.4 cm (2.9 in.)
CS60HX01L3 Clarisolve® 60 µm Depth Filters in µPod® Format, 23 cm2 (0.025 ft2) 304 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique (on filter media only)
  • Catalogue Number
  • CS60HX01L3
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • µPod
  • Device Material
  • Polypropylene
  • Filter Grade
  • 60HX
  • Filtration Area
  • 0.0023 m²
  • Height
  • 6.99 cm (2.75 in.)
  • Length
  • 9.07 cm (3.57 in.)
  • Material Size
  • 3
  • Materials of Construction
  • Polypropylene (PP)
  • Maximum Differential Pressure, bar (psid)
  • Maximum: 3.5 bar (50 psid) @ ≤ 40 °C; Forward: 2.1 bar (30 psid) @ 40 °C; Reverse: 1.0 bar (15 psid) @ 40 °C
  • Sterilization
  • 2 autoclave cycles of 60 minutes at 123 °C
  • Trade Name
  • Clarisolve®
  • Width
  • 4.60 cm (1.81 in.)
CS60HX01L3 Clarisolve® 60 µm Depth Filters in µPod® Format, 23 cm2 (0.025 ft2) 304 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique (on filter media only)
  • Catalogue Number
  • CS60HX01L3
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • µPod
  • Device Material
  • Polypropylene
  • Filter Grade
  • 60HX
  • Filtration Area
  • 0.0023 m²
  • Height
  • 6.99 cm (2.75 in.)
  • Length
  • 9.07 cm (3.57 in.)
  • Material Size
  • 3
  • Materials of Construction
  • Polypropylene (PP)
  • Maximum Differential Pressure, bar (psid)
  • Maximum: 3.5 bar (50 psid) @ ≤ 40 °C; Forward: 2.1 bar (30 psid) @ 40 °C; Reverse: 1.0 bar (15 psid) @ 40 °C
  • Sterilization
  • 2 autoclave cycles of 60 minutes at 123 °C
  • Trade Name
  • Clarisolve®
  • Width
  • 4.60 cm (1.81 in.)
CS60HX02H1 Clarisolve® 60 µm Lab Scale Depth Filters, 0.027 m2 (0.29 ft2) 346 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique (on filter media only)
  • Catalogue Number
  • CS60HX02H1
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • lab scale Pod
  • Device Material
  • Polypropylene
  • Filter Grade
  • 60HX
  • Filtration Area
  • 0.027 m²
  • Height
  • 14 cm (5.3 in.)
  • Length
  • 22 cm (8.5 in.)
  • Material Size
  • 1
  • Materials of Construction
  • Polypropylene (PP)
  • Maximum Differential Pressure, bar (psid)
  • Maximum: 2.1 bar (30 psid) @ 37 °C; Forward: 2.1 bar (30 psid) @ 4 ° or 37 °C; Reverse: 2.1 bar (30 psid) @ 37 °C
  • Seal Material
  • Thermo Plastic Elastomer (TPE)
  • Sterilization
  • Integrity is maintained after 2 autoclave cycles of 60 minutes at 123 °C.
  • Trade Name
  • Clarisolve®
  • Width
  • 9.4 cm (3.7 in.)
CS20MS01F1-X Clarisolve® 20 µm Pod Depth Filters, 0.11 m2 (1.18 ft2) 377 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
  • Catalogue Number
  • CS20MS01F1-X
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Pod
  • Device Material
  • Polypropylene
  • Filter Grade
  • 20MS
  • Filtration Area
  • 0.11 m²
  • Height
  • 32 cm (12.5 in.)
  • Length
  • 62 cm (24.2 in.)
  • Material Size
  • 1
  • Materials of Construction
  • Polypropylene and Millistak+® media
  • Maximum Differential Pressure, bar (psid)
  • Maximum: 3.5 bar (50 psid) @ ≤ 25 °C or 1.0 bar (15 psid) @ ≤ 80 °C; Forward: 2.1 bar (30 psid) @
  • Media
  • Seal Material
  • Seal Material
  • Thermo Plastic Elastomer (TPE)
  • Sterilization
  • Integrity is maintained after 1 autoclave cycle of 60 minutes at 123 °C.
  • Trade Name
  • Clarisolve®
  • Width
  • 5.8 cm (2 in)
CS40MS01F1-X Clarisolve® 40 µm Pod Depth Filters, 0.11 m2 (1.18 ft2) 377 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
  • Catalogue Number
  • CS40MS01F1-X
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Pod
  • Device Material
  • Polypropylene
  • Filter Grade
  • 40MS
  • Filtration Area
  • 0.11 m²
  • Height
  • 32 cm (12.5 in.)
  • Length
  • 62 cm (24.2 in.)
  • Material Size
  • 1
  • Materials of Construction
  • Polypropylene and Millistak+® media
  • Maximum Differential Pressure, bar (psid)
  • Maximum: 3.5 bar (50 psid) @ ≤ 25 °C or 1.0 bar (15 psid) @ ≤ 80 °C; Forward: 2.1 bar (30 psid) @
  • Media
  • Seal Material
  • Seal Material
  • Thermo Plastic Elastomer (TPE)
  • Sterilization
  • Integrity is maintained after 1 autoclave cycle of 60 minutes at 123 °C.
  • Trade Name
  • Clarisolve®
  • Width
  • 5.8 cm (2 in)
CS60HX01F1-X Clarisolve® 60 µm Pod Depth Filters, 0.11 m2 (1.18 ft2) 419 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
  • Catalogue Number
  • CS60HX01F1-X
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Pod
  • Device Material
  • Polypropylene
  • Filter Grade
  • 60HX
  • Filtration Area
  • 0.11 m²
  • Height
  • 32 cm (12.5 in.)
  • Length
  • 62 cm (24.2 in.)
  • Material Size
  • 1
  • Materials of Construction
  • Polypropylene
  • Maximum Differential Pressure, bar (psid)
  • Maximum: 3.5 bar (50 psid) @ ≤ 25 °C or 1.0 bar (15 psid) @ ≤ 80 °C; Forward: 2.1 bar (30 psid) @
  • Seal Material
  • Thermo Plastic Elastomer (TPE)
  • Sterilization
  • Integrity is maintained after 1 autoclave cycle of 60 minutes at 123 °C.
  • Trade Name
  • Clarisolve®
  • Width
  • 5.8 cm (2 in)

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources