We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
L25CET6S1
Chemistry
Cellulose (CL)
Device Configuration
Stack Disk
Device Material
Polypropylene
Diameter
40.64 cm (16 in.)
Filter Grade
CE25
Filtration Area
3.47 m²
Height
27.6 cm (10.88 in.)
Material Size
1
Maximum Differential Pressure, bar (psid)
Forward: 2.07 bar (30 psid) @ 25 °C; 1.03 bar (15 psid) @ 80 °C
Maximum Inlet Pressure, bar (psi)
2.1 bar (30 psi) @ 25 °C; 1 bar (15 psi) @ 80 °C; 0.2 bar (3 psi) @ 123 °C
Oxidizable Substances
The effluent of an autoclaved (1 cycle of 30 minutes @ 123 °C) stacked device is negative after a WFI flush of 10 liters per ft2 (100 L/m2) of media surface area
Sanitization
May be hot water sanitized for 20 cycles using purified water @ 80 °C for 30 minutes
Seal Material
Silicone (SI)
Sterilization
May be steam sterilized for 3 steam-in-place (SIP) cycles of 30 minutes @ 123 °C
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
L25DET6S1
Chemistry
Cellulose (CL)Inorganic Filter Aid
Device Configuration
Stack Disk
Device Material
Polypropylene
Diameter
40.64 cm (16 in.)
Filter Grade
DE25
Filtration Area
3.47 m²
Gravimetric Extractables
Post autoclave (1 cycle of 30 minutes at 123 °C) and pure water flush of 50 L/m2 of media surface area.NVR: 3.93–6.43 mg/m2TOC: 753–1,567 ppb
Height
27.6 cm (10.88 in.)
Material Size
1
Maximum Differential Pressure, bar (psid)
Forward: 2.07 bar (30 psid) @ 25 °C; 1.03 bar (15 psid) @ 80 °C; 0.21 bar (3 psid) @ 123 °C. Reverse: 0.03 bar (0.5 psid)
Maximum Inlet Pressure, bar (psi)
2.1 bar (30 psi) @ 25 °C; 1 bar (15 psi) @ 80 °C; 0.2 bar (3 psi) @ 123 °C
Oxidizable Substances
The effluent of an autoclaved (1 cycle of 30 minutes @ 123 °C) stacked device is negative after a WFI flush of 5 liters per ft2 (50 L/m2) of media surface area
Sanitization
May be hot water sanitized for 20 cycles using purified water @ 80 °C for 30 minutes
Seal Material
Silicone (SI)
Sterilization
May be steam sterilized for 3 steam-in-place (SIP) cycles of 30 minutes @ 123 °C
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
L25DET6S1
Chemistry
Cellulose (CL)Inorganic Filter Aid
Device Configuration
Stack Disk
Device Material
Polypropylene
Diameter
40.64 cm (16 in.)
Filter Grade
DE25
Filtration Area
3.47 m²
Gravimetric Extractables
Post autoclave (1 cycle of 30 minutes at 123 °C) and pure water flush of 50 L/m2 of media surface area.NVR: 3.93–6.43 mg/m2TOC: 753–1,567 ppb
Height
27.6 cm (10.88 in.)
Material Size
1
Maximum Differential Pressure, bar (psid)
Forward: 2.07 bar (30 psid) @ 25 °C; 1.03 bar (15 psid) @ 80 °C; 0.21 bar (3 psid) @ 123 °C. Reverse: 0.03 bar (0.5 psid)
Maximum Inlet Pressure, bar (psi)
2.1 bar (30 psi) @ 25 °C; 1 bar (15 psi) @ 80 °C; 0.2 bar (3 psi) @ 123 °C
Oxidizable Substances
The effluent of an autoclaved (1 cycle of 30 minutes @ 123 °C) stacked device is negative after a WFI flush of 5 liters per ft2 (50 L/m2) of media surface area
Sanitization
May be hot water sanitized for 20 cycles using purified water @ 80 °C for 30 minutes
Seal Material
Silicone (SI)
Sterilization
May be steam sterilized for 3 steam-in-place (SIP) cycles of 30 minutes @ 123 °C
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
L30DET6S1
Chemistry
Cellulose (CL)Inorganic Filter Aid
Device Configuration
Stack Disk
Device Material
Polypropylene
Diameter
40.64 cm (16 in.)
Filter Grade
DE30
Filtration Area
3.47 m²
Height
27.6 cm (10.88 in.)
Material Size
1
Maximum Differential Pressure, bar (psid)
Forward: 2.07 bar (30 psid) @ 25 °C; 1.03 bar (15 psid) @ 80 °C; 0.21 bar (3 psid) @ 123 °C. Reverse: 0.03 bar (0.5 psid)
Maximum Inlet Pressure, bar (psi)
2.1 bar (30 psi) @ 25 °C; 1 bar (15 psi) @ 80 °C; 0.2 bar (3 psi) @ 123 °C
Oxidizable Substances
The effluent of an autoclaved (1 cycle of 30 minutes @ 123 °C) stacked device is negative after a WFI flush of 5 liters per ft2 (50 L/m2) of media surface area
Sanitization
May be hot water sanitized for 20 cycles using purified water @ 80 °C for 30 minutes
Seal Material
Silicone (SI)
Sterilization
May be steam sterilized for 3 steam-in-place (SIP) cycles of 30 minutes @ 123 °C
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
L30DET6S1
Chemistry
Cellulose (CL)Inorganic Filter Aid
Device Configuration
Stack Disk
Device Material
Polypropylene
Diameter
40.64 cm (16 in.)
Filter Grade
DE30
Filtration Area
3.47 m²
Height
27.6 cm (10.88 in.)
Material Size
1
Maximum Differential Pressure, bar (psid)
Forward: 2.07 bar (30 psid) @ 25 °C; 1.03 bar (15 psid) @ 80 °C; 0.21 bar (3 psid) @ 123 °C. Reverse: 0.03 bar (0.5 psid)
Maximum Inlet Pressure, bar (psi)
2.1 bar (30 psi) @ 25 °C; 1 bar (15 psi) @ 80 °C; 0.2 bar (3 psi) @ 123 °C
Oxidizable Substances
The effluent of an autoclaved (1 cycle of 30 minutes @ 123 °C) stacked device is negative after a WFI flush of 5 liters per ft2 (50 L/m2) of media surface area
Sanitization
May be hot water sanitized for 20 cycles using purified water @ 80 °C for 30 minutes
Seal Material
Silicone (SI)
Sterilization
May be steam sterilized for 3 steam-in-place (SIP) cycles of 30 minutes @ 123 °C
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
L35DET6S1
Chemistry
Cellulose (CL)Inorganic Filter Aid
Device Configuration
Stack Disk
Device Material
Polypropylene
Diameter
40.64 cm (16 in.)
Filter Grade
DE35
Filtration Area
3.47 m²
Height
27.6 cm (10.88 in.)
Material Size
1
Maximum Differential Pressure, bar (psid)
Forward: 2.07 bar (30 psid) @ 25 °C; 1.03 bar (15 psid) @ 80 °C; 0.21 bar (3 psid) @ 123 °C. Reverse: 0.03 bar (0.5 psid)
Maximum Inlet Pressure, bar (psi)
2.1 bar (30 psi) @ 25 °C; 1 bar (15 psi) @ 80 °C; 0.2 bar (3 psi) @ 123 °C
Oxidizable Substances
The effluent of an autoclaved (1 cycle of 30 minutes @ 123 °C) stacked device is negative after a WFI flush of 5 liters per ft2 (50 L/m2) of media surface area
Sanitization
May be hot water sanitized for 20 cycles using purified water @ 80 °C for 30 minutes
Seal Material
Silicone (SI)
Sterilization
May be steam sterilized for 3 steam-in-place (SIP) cycles of 30 minutes @ 123 °C
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
L35DET6S1
Chemistry
Cellulose (CL)Inorganic Filter Aid
Device Configuration
Stack Disk
Device Material
Polypropylene
Diameter
40.64 cm (16 in.)
Filter Grade
DE35
Filtration Area
3.47 m²
Height
27.6 cm (10.88 in.)
Material Size
1
Maximum Differential Pressure, bar (psid)
Forward: 2.07 bar (30 psid) @ 25 °C; 1.03 bar (15 psid) @ 80 °C; 0.21 bar (3 psid) @ 123 °C. Reverse: 0.03 bar (0.5 psid)
Maximum Inlet Pressure, bar (psi)
2.1 bar (30 psi) @ 25 °C; 1 bar (15 psi) @ 80 °C; 0.2 bar (3 psi) @ 123 °C
Oxidizable Substances
The effluent of an autoclaved (1 cycle of 30 minutes @ 123 °C) stacked device is negative after a WFI flush of 5 liters per ft2 (50 L/m2) of media surface area
Sanitization
May be hot water sanitized for 20 cycles using purified water @ 80 °C for 30 minutes
Seal Material
Silicone (SI)
Sterilization
May be steam sterilized for 3 steam-in-place (SIP) cycles of 30 minutes @ 123 °C
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
L35CET6S1
Chemistry
Cellulose (CL)
Device Configuration
Stack Disk
Device Material
Polypropylene
Diameter
40.64 cm (16 in.)
Filter Grade
CE35
Filtration Area
3.47 m²
Height
27.6 cm (10.88 in.)
Material Size
1
Maximum Differential Pressure, bar (psid)
Forward: 2.07 bar (30 psid) @ 25 °C; 1.03 bar (15 psid) @ 80 °C
Oxidizable Substances
The effluent of an autoclaved (1 cycle of 30 minutes @ 123 °C) stacked device is negative after a WFI flush of 10 liters per ft2 (100 L/m2) of media surface area
Sanitization
May be hot water sanitized for 20 cycles using purified water @ 80 °C for 30 minutes
Seal Material
Silicone (SI)
Sterilization
May be steam sterilized for 3 steam-in-place (SIP) cycles of 30 minutes @ 123 °C
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
L40CET6S1
Chemistry
Cellulose (CL)
Device Configuration
Stack Disk
Device Material
Polypropylene
Diameter
40.64 cm (16 in.)
Filter Grade
CE40
Filtration Area
3.47 m²
Height
27.6 cm (10.88 in.)
Material Size
1
Maximum Differential Pressure, bar (psid)
Forward: 2.07 bar (30 psid) @ 25 °C; 1.03 bar (15 psid) @ 80 °C
Oxidizable Substances
The effluent of an autoclaved (1 cycle of 30 minutes @ 123 °C) stacked device is negative after a WFI flush of 10 liters per ft2 (100 L/m2) of media surface area
Sanitization
May be hot water sanitized for 20 cycles using purified water @ 80 °C for 30 minutes
Seal Material
Silicone (SI)
Sterilization
May be steam sterilized for 3 steam-in-place (SIP) cycles of 30 minutes @ 123 °C
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
L40CET6S1
Chemistry
Cellulose (CL)
Device Configuration
Stack Disk
Device Material
Polypropylene
Diameter
40.64 cm (16 in.)
Filter Grade
CE40
Filtration Area
3.47 m²
Height
27.6 cm (10.88 in.)
Material Size
1
Maximum Differential Pressure, bar (psid)
Forward: 2.07 bar (30 psid) @ 25 °C; 1.03 bar (15 psid) @ 80 °C
Oxidizable Substances
The effluent of an autoclaved (1 cycle of 30 minutes @ 123 °C) stacked device is negative after a WFI flush of 10 liters per ft2 (100 L/m2) of media surface area
Sanitization
May be hot water sanitized for 20 cycles using purified water @ 80 °C for 30 minutes
Seal Material
Silicone (SI)
Sterilization
May be steam sterilized for 3 steam-in-place (SIP) cycles of 30 minutes @ 123 °C
Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.
Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.