+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
VCWP14250 MF-Millipore™ Membrane Filter, 0.1 µm pore size 424 
Add to Cart
  • Air Flow Rate
  • 0.4 L/min x cm²
  • Background Information
  • Biologically inert mixtures of cellulose acetate and cellulose nitrate have made MF-Millipore™ membrane filters one of the most widely used membranes in analytical and research applications. MF-Millipore™ filters without Triton® surfactant contain minimum amounts of wetting agent and have a lower water extractable content than standard MF-Millipore™ filters.Features & Benefits: - Versatile filter for biological and environmental monitoring applications - Available in a range of pore sizes, colored black or white, with or without a gridded surface - Compatible with ethylene oxide, gamma irradiation, and autoclave sterilization methods
  • Catalogue Number
  • VCWP14250
  • Chemistry
  • Mixed Cellulose Esters (MCE)
  • Filter Code
  • VCWP
  • Filter Color
  • White
  • Filter Diameter (⌀)
  • 142 mm
  • Filter Surface
  • Plain
  • Flow Rate
  • 0.4 L/min x cm²
  • Gravimetric Extractables
  • 1.5%
  • Material Size
  • Hydrophilic, 0.1 µm, 142 mm, white, plain, 50
  • Maximum Operating Temperature
  • 75 °C
  • Media
  • MF-Millipore
  • Pore Size
  • Background Information
  • Porosity %
  • 74%
  • Thickness
  • 100 µm
  • Trade Name
  • MF-Millipore
  • Wettability
  • Hydrophilic
VSWP14250 MF-Millipore™ Membrane Filter, 0.025 µm pore size 424 
Add to Cart
  • Air Flow Rate
  • 0.15 L/min x cm²
  • Background Information
  • Biologically inert mixtures of cellulose acetate and cellulose nitrate have made MF-Millipore™ membrane filters one of the most widely used membranes in analytical and research applications. MF-Millipore™ filters without Triton® surfactant contain minimum amounts of wetting agent and have a lower water extractable content than standard MF-Millipore™ filters.Features & Benefits: - Versatile filter for biological and environmental monitoring applications - Available in a range of pore sizes, colored black or white, with or without a gridded surface - Compatible with ethylene oxide, gamma irradiation, and autoclave sterilization methods
  • Catalogue Number
  • VSWP14250
  • Chemistry
  • Mixed Cellulose Esters (MCE)
  • Filter Code
  • VSWP
  • Filter Color
  • White
  • Filter Diameter (⌀)
  • 142 mm
  • Filter Surface
  • Plain
  • Flow Rate
  • 0.15 L/min x cm²
  • Gravimetric Extractables
  • 1.5%
  • Material Size
  • Hydrophilic, 0.025 µm, 142 mm, white, plain, 50
  • Maximum Operating Temperature
  • 75 °C
  • Media
  • MF-Millipore
  • Pore Size
  • Background Information
  • Porosity %
  • 72%
  • Thickness
  • 100 µm
  • Trade Name
  • MF-Millipore
  • Wettability
  • Hydrophilic
RAWP14250 MF-Millipore™ Membrane Filter, 1.2 µm pore size Special offer 
Add to Cart
  • Air Flow Rate
  • 20 L/min x cm²
  • Background Information
  • Biologically inert mixtures of cellulose acetate and cellulose nitrate have made MF-Millipore™ membrane filters one of the most widely used membranes in analytical and research applications. MF-Millipore™ filters without Triton® surfactant contain minimum amounts of wetting agent and have a lower water extractable content than standard MF-Millipore™ filters.Features & Benefits: - Versatile filter for biological and environmental monitoring applications - Available in a range of pore sizes, colored black or white, with or without a gridded surface - Compatible with ethylene oxide, gamma irradiation, and autoclave sterilization methods
  • Catalogue Number
  • RAWP14250
  • Chemistry
  • Mixed Cellulose Esters (MCE)
  • Filter Code
  • RAWP
  • Filter Color
  • White
  • Filter Diameter (⌀)
  • 142 mm
  • Filter Surface
  • Plain
  • Flow Rate
  • 20 L/min x cm²
  • Gravimetric Extractables
  • 5%
  • Material Size
  • Hydrophilic, 1.2 µm, 142 mm, white, plain, 50
  • Maximum Operating Temperature
  • 75 °C
  • Media
  • MF-Millipore
  • Pore Size
  • Background Information
  • Porosity %
  • 82%
  • Thickness
  • 150 µm
  • Trade Name
  • MF-Millipore
  • Wettability
  • Hydrophilic
VSWP14250 MF-Millipore™ Membrane Filter, 0.025 µm pore size Special offer 
Add to Cart
  • Air Flow Rate
  • 0.15 L/min x cm²
  • Background Information
  • Biologically inert mixtures of cellulose acetate and cellulose nitrate have made MF-Millipore™ membrane filters one of the most widely used membranes in analytical and research applications. MF-Millipore™ filters without Triton® surfactant contain minimum amounts of wetting agent and have a lower water extractable content than standard MF-Millipore™ filters.Features & Benefits: - Versatile filter for biological and environmental monitoring applications - Available in a range of pore sizes, colored black or white, with or without a gridded surface - Compatible with ethylene oxide, gamma irradiation, and autoclave sterilization methods
  • Catalogue Number
  • VSWP14250
  • Chemistry
  • Mixed Cellulose Esters (MCE)
  • Filter Code
  • VSWP
  • Filter Color
  • White
  • Filter Diameter (⌀)
  • 142 mm
  • Filter Surface
  • Plain
  • Flow Rate
  • 0.15 L/min x cm²
  • Gravimetric Extractables
  • 1.5%
  • Material Size
  • Hydrophilic, 0.025 µm, 142 mm, white, plain, 50
  • Maximum Operating Temperature
  • 75 °C
  • Media
  • MF-Millipore
  • Pore Size
  • Background Information
  • Porosity %
  • 72%
  • Thickness
  • 100 µm
  • Trade Name
  • MF-Millipore
  • Wettability
  • Hydrophilic
GSTF14250 MF-Millipore™ Membrane Filter, Triton®-free, 0.22 µm pore size 281 
Add to Cart
  • Air Flow Rate
  • 2 L/min x cm²
  • Background Information
  • Biologically inert mixtures of cellulose acetate and cellulose nitrate have made MF-Millipore™ membrane filters one of the most widely used membranes in analytical and research applications. MF-Millipore™ filters without Triton® surfactant contain minimum amounts of wetting agent and have a lower water extractable content than standard MF-Millipore™ filters.Features & Benefits: - Versatile filter for biological and environmental monitoring applications - Available in a range of pore sizes, colored black or white, with or without a gridded surface - Compatible with ethylene oxide, gamma irradiation, and autoclave sterilization methods
  • Catalogue Number
  • GSTF14250
  • Chemistry
  • Mixed Cellulose Esters (MCE)
  • Filter Code
  • GSTF
  • Filter Color
  • White
  • Filter Diameter (⌀)
  • 142 mm
  • Filter Surface
  • Plain
  • Flow Rate
  • 2 L/min x cm²
  • Gravimetric Extractables
  • < 2%
  • Material Size
  • Triton-free, Hydrophilic, 0.22 µm, 142 mm, 50
  • Maximum Operating Temperature
  • 75 °C
  • Media
  • MF-Millipore
  • Pore Size
  • Background Information
  • Porosity %
  • 75%
  • Thickness
  • 150 µm
  • Trade Name
  • MF-Millipore
  • Wettability
  • Hydrophilic
GSTF14250 MF-Millipore™ Membrane Filter, Triton®-free, 0.22 µm pore size 281 
Add to Cart
  • Air Flow Rate
  • 2 L/min x cm²
  • Background Information
  • Biologically inert mixtures of cellulose acetate and cellulose nitrate have made MF-Millipore™ membrane filters one of the most widely used membranes in analytical and research applications. MF-Millipore™ filters without Triton® surfactant contain minimum amounts of wetting agent and have a lower water extractable content than standard MF-Millipore™ filters.Features & Benefits: - Versatile filter for biological and environmental monitoring applications - Available in a range of pore sizes, colored black or white, with or without a gridded surface - Compatible with ethylene oxide, gamma irradiation, and autoclave sterilization methods
  • Catalogue Number
  • GSTF14250
  • Chemistry
  • Mixed Cellulose Esters (MCE)
  • Filter Code
  • GSTF
  • Filter Color
  • White
  • Filter Diameter (⌀)
  • 142 mm
  • Filter Surface
  • Plain
  • Flow Rate
  • 2 L/min x cm²
  • Gravimetric Extractables
  • < 2%
  • Material Size
  • Triton-free, Hydrophilic, 0.22 µm, 142 mm, 50
  • Maximum Operating Temperature
  • 75 °C
  • Media
  • MF-Millipore
  • Pore Size
  • Background Information
  • Porosity %
  • 75%
  • Thickness
  • 150 µm
  • Trade Name
  • MF-Millipore
  • Wettability
  • Hydrophilic
HATF14250 Immobilon-NC Transfer Membrane 281 
Add to Cart
  • Air Flow Rate
  • 4 L/min x cm²
  • Background Information
  • Biologically inert mixtures of cellulose acetate and cellulose nitrate have made MF-Millipore™ membrane filters one of the most widely used membranes in analytical and research applications. MF-Millipore™ filters without Triton® surfactant contain minimum amounts of wetting agent and have a lower water extractable content than standard MF-Millipore™ filters.Features & Benefits: - Versatile filter for biological and environmental monitoring applications - Available in a range of pore sizes, colored black or white, with or without a gridded surface - Compatible with ethylene oxide, gamma irradiation, and autoclave sterilization methods
  • Catalogue Number
  • HATF14250
  • Chemistry
  • Mixed Cellulose Esters, Surfactant-Free
  • Filter Code
  • HATF
  • Filter Color
  • White
  • Filter Diameter (⌀)
  • 142 mm
  • Filter Surface
  • Plain
  • Flow Rate
  • 4 L/min x cm²
  • Key Applications
  • Western Blotting
  • Material Size
  • 50
  • Maximum Operating Temperature
  • 75 °C
  • Media
  • Immobilon®
  • Pore Size
  • 0.45 µm
  • Porosity %
  • 79%
  • Thickness
  • 150 µm
  • Trade Name
  • Immobilon
  • Wettability
  • Hydrophilic
HATF14250 Immobilon-NC Transfer Membrane 281 
Add to Cart
  • Air Flow Rate
  • 4 L/min x cm²
  • Background Information
  • Biologically inert mixtures of cellulose acetate and cellulose nitrate have made MF-Millipore™ membrane filters one of the most widely used membranes in analytical and research applications. MF-Millipore™ filters without Triton® surfactant contain minimum amounts of wetting agent and have a lower water extractable content than standard MF-Millipore™ filters.Features & Benefits: - Versatile filter for biological and environmental monitoring applications - Available in a range of pore sizes, colored black or white, with or without a gridded surface - Compatible with ethylene oxide, gamma irradiation, and autoclave sterilization methods
  • Catalogue Number
  • HATF14250
  • Chemistry
  • Mixed Cellulose Esters, Surfactant-Free
  • Filter Code
  • HATF
  • Filter Color
  • White
  • Filter Diameter (⌀)
  • 142 mm
  • Filter Surface
  • Plain
  • Flow Rate
  • 4 L/min x cm²
  • Key Applications
  • Western Blotting
  • Material Size
  • 50
  • Maximum Operating Temperature
  • 75 °C
  • Media
  • Immobilon®
  • Pore Size
  • 0.45 µm
  • Porosity %
  • 79%
  • Thickness
  • 150 µm
  • Trade Name
  • Immobilon
  • Wettability
  • Hydrophilic
RW0614250 Reinforced Membrane Filter 118 
Add to Cart
  • Background Information
  • Reinforced prefilter membranes can be used to remove contaminants from a variety of liquids and gases. The filters have a high dirt-holding capacity and a low pressure drop, which makes them ideally suited for reducing contaminant levels in advance of sterilizing-grade filters. Unlike traditional prefilter materials that contain asbestos or fiberglass, our reinforced prefilter membranes are made from non-shedding materials. These filters retain contaminants on the surface of the cellulose membrane.Features & Benefits:•Prefilter with high dirt-loading capacity for greater throughput •Non-shedding substrate will not unload fibers downstream Applications:Prefiltration Ahead of Sterilizing-Grade Filters
  • Catalogue Number
  • RW0614250
  • Chemistry
  • Mixed Cellulose Esters (MCE)Cellulose Web
  • Filter Code
  • RW06
  • Filter Color
  • White
  • Filter Diameter (⌀)
  • 142 mm
  • Filter Surface
  • Plain
  • Filter Type
  • Screen filter
  • Flow Rate
  • 150 mL/min x cm²
  • Material Size
  • 50
  • Maximum Operating Temperature
  • 70 °C
  • Pore Size
  • 0.5 µm
  • Porosity %
  • 75%
  • Thickness
  • 200 µm
  • Wettability
  • Hydrophilic
RW0614250 Reinforced Membrane Filter 118 
Add to Cart
  • Background Information
  • Reinforced prefilter membranes can be used to remove contaminants from a variety of liquids and gases. The filters have a high dirt-holding capacity and a low pressure drop, which makes them ideally suited for reducing contaminant levels in advance of sterilizing-grade filters. Unlike traditional prefilter materials that contain asbestos or fiberglass, our reinforced prefilter membranes are made from non-shedding materials. These filters retain contaminants on the surface of the cellulose membrane.Features & Benefits:•Prefilter with high dirt-loading capacity for greater throughput •Non-shedding substrate will not unload fibers downstream Applications:Prefiltration Ahead of Sterilizing-Grade Filters
  • Catalogue Number
  • RW0614250
  • Chemistry
  • Mixed Cellulose Esters (MCE)Cellulose Web
  • Filter Code
  • RW06
  • Filter Color
  • White
  • Filter Diameter (⌀)
  • 142 mm
  • Filter Surface
  • Plain
  • Filter Type
  • Screen filter
  • Flow Rate
  • 150 mL/min x cm²
  • Material Size
  • 50
  • Maximum Operating Temperature
  • 70 °C
  • Pore Size
  • 0.5 µm
  • Porosity %
  • 75%
  • Thickness
  • 200 µm
  • Wettability
  • Hydrophilic

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources