+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
MP0DSYS1X Process Scale Holders 1 Rack 18195 
Add to Cart
  • Cartridge Used
  • Pod Filters
  • Catalogue Number
  • MP0DSYS1X
  • Material Size
  • 1
MP0DSYS1X Process Scale Holders 1 Rack 18195 
Add to Cart
  • Cartridge Used
  • Pod Filters
  • Catalogue Number
  • MP0DSYS1X
  • Material Size
  • 1
MP0DSYS1A Process Scale Holders 1 Rack 21619 
Add to Cart
  • Cartridge Used
  • Pod Filters
  • Catalogue Number
  • MP0DSYS1A
  • Connections, Gauge Port
  • 1-1/2 in. Sanitary Flange
  • Material Size
  • 1
  • Materials of Construction
  • 316L stainless steel
  • Seal Material
  • Silicone (SI)
MP0DSYS1A Process Scale Holders 1 Rack 21619 
Add to Cart
  • Cartridge Used
  • Pod Filters
  • Catalogue Number
  • MP0DSYS1A
  • Connections, Gauge Port
  • 1-1/2 in. Sanitary Flange
  • Material Size
  • 1
  • Materials of Construction
  • 316L stainless steel
  • Seal Material
  • Silicone (SI)
MP0DSYS1N Process Scale Holders 1 Rack 19958 
Add to Cart
  • Cartridge Used
  • Pod Filters
  • Catalogue Number
  • MP0DSYS1N
  • Connections, Gauge Port
  • 1-1/2 in. Sanitary Flange
  • Material Size
  • 1
  • Materials of Construction
  • 316L stainless steel
  • Seal Material
  • Silicone (SI)
MP0DSYS1N Process Scale Holders 1 Rack 19958 
Add to Cart
  • Cartridge Used
  • Pod Filters
  • Catalogue Number
  • MP0DSYS1N
  • Connections, Gauge Port
  • 1-1/2 in. Sanitary Flange
  • Material Size
  • 1
  • Materials of Construction
  • 316L stainless steel
  • Seal Material
  • Silicone (SI)
MP0DSYS1B Process Scale Holders 1 Rack 22014 
Add to Cart
  • Cartridge Used
  • Pod Filters
  • Catalogue Number
  • MP0DSYS1B
  • Connections, Gauge Port
  • 1-1/2 in. Sanitary Flange
  • Material Size
  • 1
  • Materials of Construction
  • 316L stainless steel
  • Seal Material
  • Silicone (SI)
MP0DSYS1B Process Scale Holders 1 Rack 22014 
Add to Cart
  • Cartridge Used
  • Pod Filters
  • Catalogue Number
  • MP0DSYS1B
  • Connections, Gauge Port
  • 1-1/2 in. Sanitary Flange
  • Material Size
  • 1
  • Materials of Construction
  • 316L stainless steel
  • Seal Material
  • Silicone (SI)
AP2501000 Glass Fiber Filter with binder 35 
Add to Cart
  • Background Information
  • OverviewMillipore fibrous disc filters are available in a wide range of flow rates and throughput capacities. Our Glass Fiber filters are available with or without binder resins and can be sterilized by EO, gamma, or autoclave (121 °C at 1 bar).Glass Fiber Filters with Binder Resin:Millipore filters with binder resin have superior wet strength and are excellent for qualitative analysis and prefiltration, especially for heavily contaminated liquids. They are also widely used for clarification of aqueous solutions.Type AP15•Lowest dirt-holding capacity •Recommended prefilter for 0.2 to 0.6 µm filters Type AP20•Lower retention, higher dirt-holding capacity than AP15 filters •Recommended prefilter for 0.8 to 8.0 µm filters •Use upstream to protect type AP15 filters Type AP25•Added thickness yields same retention and greater dirt-holding capacity as AP20 •Recommended prefilter for 0.9 to 8 µm filters, especially for proteinaceous and heavily contaminated liquids •Use upstream to protect type AP15 filters Glass Fiber Filters without Binder Resin:The filters without binder resin retain their structural integrity without weight loss when heated up to 500 °C and can therefore be used in gravimetric analysis as well as for the filtration of hot gases.Type APFA•Retains fine particles with good efficiency, even at high flow rates •Recommended for monitoring wastewater and collecting suspended particles in gases (e.g., fumes from chimneys) •Use in biochemical applications (e.g., collection of cells and filtration of protein or nucleic acid precipitates) Type APFB•Higher mechanical strength when wet and greater loading capacity than type APFA filters •Use for liquid clarification, quantification of solids in suspensions of fine particles, and scintillation counting Type APFC•Greater retention, especially for fine particulate and microorganism removal than type APFA filters •Use for determining total suspended solids in drinking water •Use for filtering proteins or nucleic acid TCA precipitates and for collecting cells and microorganisms Type APFD•Thick filter with high flow and low retention •Use for clarifying suspensions containing particulates greater than 1.0 µm Type APFF•Use for filtering extremely fine precipitates such as protein, nucleic acids, or serum precipitates •Recommended for USEPA method 1311 for TCLP analysis Type AP40•Recommended for Standard Methods Total Suspended Solids 2540D •Recommended for USEPA method 1311 for TCLP analysis •Maintains structural integrity without weight loss when ignited to 550 °C (1022 °F) after sample filtration •Recommended for determining volatile suspended matter in wastewater and industrial effluents
  • Catalogue Number
  • AP2501000
  • Chemistry
  • Glass Fiber with Binder Resin
  • Diameter
  • Biological Information Wettability
  • Filter Code
  • AP25
  • Filter Color
  • White
  • Filter Diameter (⌀)
  • 10 mm
  • Filter Surface
  • Plain
  • Filter Type
  • Depth filter
  • Flow Rate
  • 5.8 mL/min x cm²
  • Material Size
  • 100 pack, AP25, 10 mm
  • Maximum Operating Temperature
  • 100 °C
  • Pore Size
  • 2.0 µm
  • Porosity %
  • 90%
  • Thickness
  • 1.2 mm
  • Wettability
  • Hydrophilic
AP2501000 Glass Fiber Filter with binder 35 
Add to Cart
  • Background Information
  • OverviewMillipore fibrous disc filters are available in a wide range of flow rates and throughput capacities. Our Glass Fiber filters are available with or without binder resins and can be sterilized by EO, gamma, or autoclave (121 °C at 1 bar).Glass Fiber Filters with Binder Resin:Millipore filters with binder resin have superior wet strength and are excellent for qualitative analysis and prefiltration, especially for heavily contaminated liquids. They are also widely used for clarification of aqueous solutions.Type AP15•Lowest dirt-holding capacity •Recommended prefilter for 0.2 to 0.6 µm filters Type AP20•Lower retention, higher dirt-holding capacity than AP15 filters •Recommended prefilter for 0.8 to 8.0 µm filters •Use upstream to protect type AP15 filters Type AP25•Added thickness yields same retention and greater dirt-holding capacity as AP20 •Recommended prefilter for 0.9 to 8 µm filters, especially for proteinaceous and heavily contaminated liquids •Use upstream to protect type AP15 filters Glass Fiber Filters without Binder Resin:The filters without binder resin retain their structural integrity without weight loss when heated up to 500 °C and can therefore be used in gravimetric analysis as well as for the filtration of hot gases.Type APFA•Retains fine particles with good efficiency, even at high flow rates •Recommended for monitoring wastewater and collecting suspended particles in gases (e.g., fumes from chimneys) •Use in biochemical applications (e.g., collection of cells and filtration of protein or nucleic acid precipitates) Type APFB•Higher mechanical strength when wet and greater loading capacity than type APFA filters •Use for liquid clarification, quantification of solids in suspensions of fine particles, and scintillation counting Type APFC•Greater retention, especially for fine particulate and microorganism removal than type APFA filters •Use for determining total suspended solids in drinking water •Use for filtering proteins or nucleic acid TCA precipitates and for collecting cells and microorganisms Type APFD•Thick filter with high flow and low retention •Use for clarifying suspensions containing particulates greater than 1.0 µm Type APFF•Use for filtering extremely fine precipitates such as protein, nucleic acids, or serum precipitates •Recommended for USEPA method 1311 for TCLP analysis Type AP40•Recommended for Standard Methods Total Suspended Solids 2540D •Recommended for USEPA method 1311 for TCLP analysis •Maintains structural integrity without weight loss when ignited to 550 °C (1022 °F) after sample filtration •Recommended for determining volatile suspended matter in wastewater and industrial effluents
  • Catalogue Number
  • AP2501000
  • Chemistry
  • Glass Fiber with Binder Resin
  • Diameter
  • Biological Information Wettability
  • Filter Code
  • AP25
  • Filter Color
  • White
  • Filter Diameter (⌀)
  • 10 mm
  • Filter Surface
  • Plain
  • Filter Type
  • Depth filter
  • Flow Rate
  • 5.8 mL/min x cm²
  • Material Size
  • 100 pack, AP25, 10 mm
  • Maximum Operating Temperature
  • 100 °C
  • Pore Size
  • 2.0 µm
  • Porosity %
  • 90%
  • Thickness
  • 1.2 mm
  • Wettability
  • Hydrophilic

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources