We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.
Polyvinylidene chloride (PVC) membranes are specified by ASTM, NIOSH, and OSHA in air monitoring applications to analyze silica, carbon black, metals, quartz particulates and others.•Filters composed of pure medical-grade PVC •Use for air monitoring applications to analyze silica, carbon black or quartz particulates •Available in 5.0 µm filters Features & Benefits:•High-quality, medical-grade PVC polymer •PVC is non-hygroscopic, so humidity will not impact your gravimetric analysis Applications:Air Monitoring of Particulate Contaminants Including Silica, Metals, and Quartz
The Millipak® 0.22 μm hydrophilic membrane filter produces particulate- and bacteria-free water at the point of dispense (POD) of the water purification systems. The filter is designed with a 0.22 μm PES (polyethersulfone) asymmetric membrane filter, heat-sealed on a SAN (styrene acrylonitrile) housing to minimize organic and inorganic extractable release. The filter can be easily fitted and replaced.
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Catalogue Number
MPGL04001
Chemistry
Polyvinylidene Fluoride (PVDF)
Device Configuration
Capsule
Diameter
1/4 in.
Fitting Outlet
Hose barb
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1.5 mg per device after 24 hours in water at controlled room temperature.
Inlet Connection
NPT
Inlet Connection Diameter
1/4 in.
Material Size
1
Media
Durapore®
Non-Fiber Releasing
This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Hose Barb
Outlet Connection Diameter
1/4 in.
Overview
Millipak® membrane filters are best-in-class proven products to provide particulate-free and bacteria-free water at the point of dispense of a water purification system. Purified water filtered through a Millipak® 40 filter can be used for any laboratory work where water free of bacteria and/or particulates is needed. This filter is connected to the outlet of the water delivery point, such as the PODs of Milli-Q® water purification systems. The filter can be easily fitted and replaced. For use with Alpha-Q and Milli-Q® Academic / Biocel / Element / Synthesis / Plus / Gradient systems
Pore Size
0.22 µm
Trade Name
Millipak®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Cartridge: Polypropylene and polyethylene, Filter: Polyethersulfone (filter) in Styrene-acrylonitrile (SAN) housing
Components
0.22 µm membrane filter
Material Size
1
Media
Durapore®
Overview
The Millipak® 0.22 μm hydrophilic membrane filter produces particulate- and bacteria-free water at the point of dispense of the water purification systems. The filter is designed with a 0.22 μm PES (polyethersulfone) asymmetric membrane filter, heat-sealed on a SAN (styrene acrylonitrile) housing to minimize organic and inorganic extractable release. The filtered water is recommended to prepare microbiological culture media, biochemistry buffers and reagents, and suitable for analytical applications.
The SmartPak® DQ3 purification pack contains a combination of purification media to produce ultrapure water from tap water. The first cartridge combines pretreatment media (activated carbon and depth filter) and a reverse osmosis (RO) membrane. The second cartridge contains ion-exchange resins. This pack includes exclusive Jetpore®, ultrapure grade mixed-bed ion-exchange resin to produce pure and ultrapure water directly from tap water. For use with Direct-Q® 3 water purification systems.
The SmartPak® RODI Purification Pack combines the purification steps of reverse osmosis (RO) and ion-exchange to produce Type 2 pure water. This pack produces DI water directly from tap water by removing a wide variety of contaminants (organics, ions, particles...). The SmartPak® RODI pack is designed for use with RiOs-DI™ water purification systems.
The bactericidal UV lamp is a built-in device that limits the bacteria level and preserves the water quality for bacteria-sensitive applications. This mercury UV lamp (254 nm) prevents bacterial growth and biofilm build-up in pure water before storing it in a polyethylene (PE) reservoir.
The bactericidal UV lamp is a built-in device that reduces the bacteria level in water to provide optimum quality pure water for bacteria-sensitive applications. This mercury UV lamp, emitting at 254 nm, is placed in the storage tank to limit bacterial growth and prevent biofilm formation, thus preserving the quality of stored pure water.
Activated carbon, mixed-bed ion-exchange resin and microfilter
Material Size
1
Overview
Q-Gard® 1 purification cartridge removes ionic and organic contaminants down to trace levels from Elix®/RO/distilled water. This replacement cartridge is constructed with clean and high-purity materials to minimize the leaching of extractable contaminants. The cartridge contains a microfilter for particulates removal, activated carbon for organics adsorption, and mixed-bed ion-exchange resin for ion removal. For use with Milli-Q® Academic/Biocel/Element /Gradient/Synthesis water systems.
Polysulfone hollow fibers for ALP and bacteria removal
Flow Rate
1.5 L/min at 1 bar and 20 °C
Inlet Connection
Gaz (Straight) Luer Slip F
Material Size
1
Overview
The BioPak® C unit is an ultrafiltration (UF) cartridge that efficiently removes bacterial by-products such as bacterial alkaline phosphatase (ALP) from feed water. It is a final, in-line purification step for immunoassay and clinical chemistry analyzers, providing optimum-quality water for use in ALP-sensitive immunoassays. The cartridge increases the stability of blanks to improve assay reliability, and reduces need for frequent analyzer calibration and costly downtime due to decontamination.
Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.
Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.