SVGLA47FF3
Optiscale® Durapore® 0.22 µm 3/4 in. TC/TC
112
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Catalogue Number
SVGLA47FF3
Chemistry
Polyvinylidene Fluoride (PVDF)
Device Configuration
Capsule
Device Material
Polycarbonate
Diameter
6.9 cm (2.7 in.)
Filtration Area
17.7 cm²
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Sanitary Flange
Inlet Connection Diameter
3/4 in.
Length
7.4 cm (2.91 in.)
Material Size
3
Maximum Differential Pressure, bar (psid)
5.5 bar (80 psid) @ 25 °C
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 25 °C
Maximum Inlet Temperature
25 °C
Media
Durapore®
Outlet Connection
Sanitary Flange
Outlet Connection Diameter
3/4 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥100 mL
Pore Size
0.22 µm
Seal Material
Fluoroelastomer (FKM)
Sterility
Other
Sterilization
3 autoclave cycles of 60 min @ 126 °C
Support Material
Polypropylene
Trade Name
OptiScale®
Vent Cap Material
Polyvinylidene fluoride (PVDF)
Wettability
Hydrophilic
SVGLA47FF3
Optiscale® Durapore® 0.22 µm 3/4 in. TC/TC
112
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Catalogue Number
SVGLA47FF3
Chemistry
Polyvinylidene Fluoride (PVDF)
Device Configuration
Capsule
Device Material
Polycarbonate
Diameter
6.9 cm (2.7 in.)
Filtration Area
17.7 cm²
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Sanitary Flange
Inlet Connection Diameter
3/4 in.
Length
7.4 cm (2.91 in.)
Material Size
3
Maximum Differential Pressure, bar (psid)
5.5 bar (80 psid) @ 25 °C
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 25 °C
Maximum Inlet Temperature
25 °C
Media
Durapore®
Outlet Connection
Sanitary Flange
Outlet Connection Diameter
3/4 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥100 mL
Pore Size
0.22 µm
Seal Material
Fluoroelastomer (FKM)
Sterility
Other
Sterilization
3 autoclave cycles of 60 min @ 126 °C
Support Material
Polypropylene
Trade Name
OptiScale®
Vent Cap Material
Polyvinylidene fluoride (PVDF)
Wettability
Hydrophilic
SVHLA47FF3
Optiscale® Capsule Filter Durapore® 0.45 µm 3/4 in. TC/TC
112
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Catalogue Number
SVHLA47FF3
Chemistry
Polyvinylidene Fluoride (PVDF)
Device Configuration
Capsule
Device Material
Polycarbonate
Diameter
6.9 cm (2.7 in.)
Filtration Area
17.7 cm²
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Sanitary Flange
Inlet Connection Diameter
3/4 in.
Material Size
3
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 25 °C
Maximum Inlet Temperature
25 °C
Media
Durapore®
Outlet Connection
Sanitary Flange
Outlet Connection Diameter
3/4 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥100 mL
Pore Size
0.45 µm
Seal Material
Fluoroelastomer (FKM)
Sterility
Other
Sterilization
3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
Support Material
Polypropylene
Trade Name
OptiScale®
Vent Cap Material
Polyvinylidene fluoride (PVDF)
Wettability
Hydrophilic
SVHLA47FF3
Optiscale® Capsule Filter Durapore® 0.45 µm 3/4 in. TC/TC
112
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Catalogue Number
SVHLA47FF3
Chemistry
Polyvinylidene Fluoride (PVDF)
Device Configuration
Capsule
Device Material
Polycarbonate
Diameter
6.9 cm (2.7 in.)
Filtration Area
17.7 cm²
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Sanitary Flange
Inlet Connection Diameter
3/4 in.
Material Size
3
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 25 °C
Maximum Inlet Temperature
25 °C
Media
Durapore®
Outlet Connection
Sanitary Flange
Outlet Connection Diameter
3/4 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥100 mL
Pore Size
0.45 µm
Seal Material
Fluoroelastomer (FKM)
Sterility
Other
Sterilization
3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
Support Material
Polypropylene
Trade Name
OptiScale®
Vent Cap Material
Polyvinylidene fluoride (PVDF)
Wettability
Hydrophilic
SVHLA47FH3
Optiscale® Capsule Filter Durapore® 0.45 µm 3/4 in. TC-1/4 in. HB
112
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Catalogue Number
SVHLA47FH3
Chemistry
Polyvinylidene Fluoride (PVDF)
Device Configuration
Capsule
Device Material
Polycarbonate
Diameter
6.9 cm (2.7 in.)
Filtration Area
17.7 cm²
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Sanitary Flange
Inlet Connection Diameter
3/4 in.
Material Size
3
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 25 °C
Maximum Inlet Temperature
25 °C
Media
Durapore®
Outlet Connection
Hose Barb
Outlet Connection Diameter
1/4 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥100 mL
Pore Size
0.45 µm
Seal Material
Fluoroelastomer (FKM)
Sterility
Other
Sterilization
3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
Support Material
Polypropylene
Trade Name
OptiScale®
Vent Cap Material
Polyvinylidene fluoride (PVDF)
Wettability
Hydrophilic
SVHLA47FH3
Optiscale® Capsule Filter Durapore® 0.45 µm 3/4 in. TC-1/4 in. HB
112
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Catalogue Number
SVHLA47FH3
Chemistry
Polyvinylidene Fluoride (PVDF)
Device Configuration
Capsule
Device Material
Polycarbonate
Diameter
6.9 cm (2.7 in.)
Filtration Area
17.7 cm²
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Sanitary Flange
Inlet Connection Diameter
3/4 in.
Material Size
3
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 25 °C
Maximum Inlet Temperature
25 °C
Media
Durapore®
Outlet Connection
Hose Barb
Outlet Connection Diameter
1/4 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥100 mL
Pore Size
0.45 µm
Seal Material
Fluoroelastomer (FKM)
Sterility
Other
Sterilization
3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
Support Material
Polypropylene
Trade Name
OptiScale®
Vent Cap Material
Polyvinylidene fluoride (PVDF)
Wettability
Hydrophilic
MPVL02GH2
Sterile Millipak®-20 Filter Unit 0.1 µm 1/4 in. HB/HB w/bell
114
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Catalogue Number
MPVL02GH2
Chemistry
Polyvinylidene Fluoride (PVDF)
Device Configuration
Gamma Gold Capsule
Device Material
Polycarbonate
Diameter
1/4 in.
Filtration Area
100 cm²
Flow Rate
0.7 L/min @ 1.75 bar ΔP
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1 mg per sterilized device after a 200 mL flush and 24 hours in water at controlled room temperature.
Inlet Connection
Hose Barb
Inlet Connection Diameter
1/4 in.
Material Package
Blister
Material Size
2
Maximum Differential Pressure, bar (psid)
Forward: 4.1 bar (60 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 123 °C; Reverse: 0.7 bar (10 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
5.2 bar (75 psi) @ 25 °C
Maximum Operating Temperature
25 °C
Media
Durapore®
Non-Fiber Releasing
This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Hose Barb with Bell
Outlet Connection Diameter
1/4 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥200 mL
Pore Size
0.1 µm
Process Volume
10 L
Sterility
Sterile
Sterilization
3 autoclave cycles of 90 min @ 123 °C; not in-line steam sterilizable
Support Material
Polycarbonate
Trade Name
Millipak®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Vent Cap Material
Polyvinylidene fluoride (PVDF)
Volume
10 L
Wettability
Hydrophilic
SW19A47HH3
Optiscale® Capsule Filter Milligard® 1.2 µm 1/4 in. HB/HB
114
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Catalogue Number
SW19A47HH3
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Capsule
Device Material
Polycarbonate
Diameter
6.9 cm (2.7 in.)
Filtration Area
17.7 cm²
Format
Single Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Hose Barb
Inlet Connection Diameter
1/4 in.
Material Size
3
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 25 °C
Maximum Inlet Temperature
25 °C
Media
Milligard®
Nominal Pore Size
1.2 µm
Outlet Connection
Hose Barb
Outlet Connection Diameter
1/4 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥100 mL
Pore Size
1.2 µm
Seal Material
Fluoroelastomer (FKM)
Sterilization
3 autoclave cycles of 60 min @ 121 °C; not in-line steam sterilizable
Support Material
Polypropylene
Trade Name
OptiScale®
Vent Cap Material
Polyvinylidene fluoride (PVDF)
SW19A47HH3
Optiscale® Capsule Filter Milligard® 1.2 µm 1/4 in. HB/HB
114
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Catalogue Number
SW19A47HH3
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Capsule
Device Material
Polycarbonate
Diameter
6.9 cm (2.7 in.)
Filtration Area
17.7 cm²
Format
Single Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Hose Barb
Inlet Connection Diameter
1/4 in.
Material Size
3
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 25 °C
Maximum Inlet Temperature
25 °C
Media
Milligard®
Nominal Pore Size
1.2 µm
Outlet Connection
Hose Barb
Outlet Connection Diameter
1/4 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥100 mL
Pore Size
1.2 µm
Seal Material
Fluoroelastomer (FKM)
Sterilization
3 autoclave cycles of 60 min @ 121 °C; not in-line steam sterilizable
Support Material
Polypropylene
Trade Name
OptiScale®
Vent Cap Material
Polyvinylidene fluoride (PVDF)
SWSCA47FF3
Optiscale® Capsule Filter Milligard® 1.2/0.5 µm 3/4 in. TC/TC
114
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Catalogue Number
SWSCA47FF3
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Capsule
Device Material
Polycarbonate
Diameter
6.9 cm (2.7 in.)
Filtration Area
17.7 cm²
Format
Double Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Sanitary Flange
Inlet Connection Diameter
3/4 in.
Material Size
3
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 25 °C
Maximum Inlet Temperature
25 °C
Media
Milligard®
Nominal Pore Size
1.2 / 0.5 µm
Outlet Connection
Sanitary Flange
Outlet Connection Diameter
3/4 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥100 mL
Pore Size
1.2 / 0.5 µm
Seal Material
Fluoroelastomer (FKM)
Sterilization
3 autoclave cycles of 60 min @ 121 °C; not in-line steam sterilizable
Support Material
Polypropylene
Trade Name
OptiScale®
Vent Cap Material
Polyvinylidene fluoride (PVDF)