+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
SHVEA47FF3 Optiscale® 47mm Millipore Express® SHR 0.5/0.1 µm 3/4 in. TC/TC 119 
Add to Cart
  • Cartridge Nominal Length
  • 2.91 in. (74 mm)
  • Catalogue Number
  • SHVEA47FF3
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Polycarbonate
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 17.7 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 3/4 in.
  • Length
  • 2.91 in. (74 mm)
  • Material Size
  • 3
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 25 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SHR w/Prefilter
  • Outlet Connection
  • Sanitary Flange
  • Outlet Connection Diameter
  • 3/4 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥100 mL
  • Pore Size
  • 0.5 / 0.1 µm
  • Seal Material
  • Fluoroelastomer (FKM)
  • Sterilization
  • 3 autoclave cycles of 60 min @ 126 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Millipore Express®
  • Vent Cap Material
  • Polyvinylidene fluoride (PVDF)
  • Wettability
  • Hydrophilic
SHVEA47FH3 Optiscale® 47mm Millipore Express® SHR 0.5/0.1 µm 3/4 in. TC-1/4 in. HB 119 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Nominal Length
  • 3.24 in. (82 mm)
  • Catalogue Number
  • SHVEA47FH3
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Polycarbonate
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 17.7 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 3/4 in.
  • Length
  • 3.24 in. (82 mm)
  • Material Size
  • 3
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 25 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SHR w/Prefilter
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 1/4 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥100 mL
  • Pore Size
  • 0.5 / 0.1 µm
  • Seal Material
  • Fluoroelastomer (FKM)
  • Sterilization
  • 3 autoclave cycles of 60 min @ 126 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Millipore Express®
  • Vent Cap Material
  • Polyvinylidene fluoride (PVDF)
  • Wettability
  • Hydrophilic
SHVEA47FH3 Optiscale® 47mm Millipore Express® SHR 0.5/0.1 µm 3/4 in. TC-1/4 in. HB 119 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Nominal Length
  • 3.24 in. (82 mm)
  • Catalogue Number
  • SHVEA47FH3
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Polycarbonate
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 17.7 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 3/4 in.
  • Length
  • 3.24 in. (82 mm)
  • Material Size
  • 3
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 25 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SHR w/Prefilter
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 1/4 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥100 mL
  • Pore Size
  • 0.5 / 0.1 µm
  • Seal Material
  • Fluoroelastomer (FKM)
  • Sterilization
  • 3 autoclave cycles of 60 min @ 126 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Millipore Express®
  • Vent Cap Material
  • Polyvinylidene fluoride (PVDF)
  • Wettability
  • Hydrophilic
SHVEA47HH3 Optiscale® 47mm Millipore Express® SHR 0.5/0.1 µm 1/4 in. HB/HB 119 
Add to Cart
  • Cartridge Nominal Length
  • 3.70 in. (94 mm)
  • Catalogue Number
  • SHVEA47HH3
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Polycarbonate
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 17.7 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Hose Barb
  • Inlet Connection Diameter
  • 1/4 in.
  • Length
  • 3.70 in. (94 mm)
  • Material Size
  • 3
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 25 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SHR w/Prefilter
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 1/4 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥100 mL
  • Pore Size
  • 0.5 / 0.1 µm
  • Seal Material
  • Fluoroelastomer (FKM)
  • Sterilization
  • 3 autoclave cycles of 60 min @ 126 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Millipore Express®
  • Vent Cap Material
  • Polyvinylidene fluoride (PVDF)
  • Wettability
  • Hydrophilic
SHVEA47HH3 Optiscale® 47mm Millipore Express® SHR 0.5/0.1 µm 1/4 in. HB/HB 119 
Add to Cart
  • Cartridge Nominal Length
  • 3.70 in. (94 mm)
  • Catalogue Number
  • SHVEA47HH3
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Polycarbonate
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 17.7 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Hose Barb
  • Inlet Connection Diameter
  • 1/4 in.
  • Length
  • 3.70 in. (94 mm)
  • Material Size
  • 3
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 25 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SHR w/Prefilter
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 1/4 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥100 mL
  • Pore Size
  • 0.5 / 0.1 µm
  • Seal Material
  • Fluoroelastomer (FKM)
  • Sterilization
  • 3 autoclave cycles of 60 min @ 126 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Millipore Express®
  • Vent Cap Material
  • Polyvinylidene fluoride (PVDF)
  • Wettability
  • Hydrophilic
MTGR65010 Aervent®-50 Filter Unit 0.2 µm hydrophobic 1/8 in. NPTM-1/4 in. HB 120 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Quantitative retention of 107 CFU/cm2 Brevundimonas diminuta (ATCC® 19146) per ASTM® F838-83 methodology
  • Catalogue Number
  • MTGR65010
  • Chemistry
  • Hydrophobic Polytetrafluoroethylene (PTFE)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Diameter
  • 6.2 cm (2.4 in.)
  • Filtration Area
  • 19.6 cm²
  • Gravimetric Extractables
  • ≤1.0 mg in 70/30 % IPA/water
  • Housing Material
  • Polypropylene (PP)
  • Length
  • 5.3 cm (2.1 in.)
  • Material Size
  • 10
  • Maximum Differential Pressure, bar (psid)
  • 2.1 bar @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.1 bar (60 psi) @ 25 °C
  • Media
  • Aervent®
  • Pore Size
  • 0.2 µm
  • Sterility
  • Non-Sterile
  • Sterilization
  • 10 autoclave cycles of 30 min @ 130 °C; not in-line steam sterilizable
  • Trade Name
  • Aervent®
  • Wettability
  • Hydrophobic
MTGR65010 Aervent®-50 Filter Unit 0.2 µm hydrophobic 1/8 in. NPTM-1/4 in. HB 120 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Quantitative retention of 107 CFU/cm2 Brevundimonas diminuta (ATCC® 19146) per ASTM® F838-83 methodology
  • Catalogue Number
  • MTGR65010
  • Chemistry
  • Hydrophobic Polytetrafluoroethylene (PTFE)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Diameter
  • 6.2 cm (2.4 in.)
  • Filtration Area
  • 19.6 cm²
  • Gravimetric Extractables
  • ≤1.0 mg in 70/30 % IPA/water
  • Housing Material
  • Polypropylene (PP)
  • Length
  • 5.3 cm (2.1 in.)
  • Material Size
  • 10
  • Maximum Differential Pressure, bar (psid)
  • 2.1 bar @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.1 bar (60 psi) @ 25 °C
  • Media
  • Aervent®
  • Pore Size
  • 0.2 µm
  • Sterility
  • Non-Sterile
  • Sterilization
  • 10 autoclave cycles of 30 min @ 130 °C; not in-line steam sterilizable
  • Trade Name
  • Aervent®
  • Wettability
  • Hydrophobic
CVDI01TPE Durapore® CVDI Cartridge Filter 10 in. 0.22 µm Code 0 fluoroelastomer 121 
Add to Cart
  • Bacterial Retention
  • Samples of the Durapore® membrane used in this cartridge were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • CVDI01TPE
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Device Size
  • 10 in.
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 0.69 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 25 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 5.5 bar (80 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 135 °C. Reverse: 3.5 bar (50 psid) @ 25 °C, intermittent
  • Media
  • Durapore®
  • Non-Fiber Releasing
  • This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Pore Size
  • 0.2 µm
  • Seal Material
  • Fluorocarbon rubber
  • Sterility
  • Other
  • Support Material
  • Polypropylene
  • Trade Name
  • Durapore®
  • Wettability
  • Hydrophilic
CVDI01TPE Durapore® CVDI Cartridge Filter 10 in. 0.22 µm Code 0 fluoroelastomer 121 
Add to Cart
  • Bacterial Retention
  • Samples of the Durapore® membrane used in this cartridge were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • CVDI01TPE
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Device Size
  • 10 in.
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 0.69 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 25 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 5.5 bar (80 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 135 °C. Reverse: 3.5 bar (50 psid) @ 25 °C, intermittent
  • Media
  • Durapore®
  • Non-Fiber Releasing
  • This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Pore Size
  • 0.2 µm
  • Seal Material
  • Fluorocarbon rubber
  • Sterility
  • Other
  • Support Material
  • Polypropylene
  • Trade Name
  • Durapore®
  • Wettability
  • Hydrophilic
SGW3A47FF3 Optiscale® Capsule Polysep® II 1.0/0.2 µm 3/4 in. TC/TC 121 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Catalogue Number
  • SGW3A47FF3
  • Chemistry
  • Borosilicate Glass Fiber (BGF) and Mixed Cellulose Esters (MCE)
  • Device Configuration
  • Capsule
  • Device Material
  • Polycarbonate
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 17.7 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 3/4 in.
  • Material Size
  • 3
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 25 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Polysep™ II
  • Nominal Pore Size
  • 1.0 / 0.2 µm
  • Outlet Connection
  • Sanitary Flange
  • Outlet Connection Diameter
  • 3/4 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥100 mL
  • Pore Size
  • 1.0 / 0.2 µm
  • Seal Material
  • Fluoroelastomer (FKM)
  • Sterilization
  • 3 autoclave cycles of 60 min @ 121 °C; not in-line steam sterilizable
  • Support Material
  • Polypropylene
  • Trade Name
  • OptiScale®
  • Vent Cap Material
  • Polyvinylidene fluoride (PVDF)

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources