Catalog No. Product Net Price
D00201S01 Clarigard Cartridge Filter 10 in. 0.2 µm Code 0 Silicone 115 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • D00201S01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤10 mg after 24-h soak in water
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.2 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L
  • Pore Size
  • 0.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic
D00271S01 Clarigard Cartridge Filter 10 in. 0.2 µm Code 7 Silicone 115 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • D00271S01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤10 mg after 24-h soak in water
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.2 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L
  • Pore Size
  • 0.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic
D00271S01 Clarigard Cartridge Filter 10 in. 0.2 µm Code 7 Silicone 115 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • D00271S01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤10 mg after 24-h soak in water
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.2 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L
  • Pore Size
  • 0.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic
D00271V01 Clarigard Cartridge Filter 10 in. 0.2 µm Code 7 Fluoroelastomer 115 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • D00271V01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤10 mg after 24-h soak in water
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.2 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L
  • Pore Size
  • 0.2 µm
  • Seal Material
  • Fluorocarbon rubber
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic
D030F3P01 Clarigard Cartridge Filter 30 in. 3.0 µm Code F PE 115 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code F double open end w/flat gaskets
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • D030F3P01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 6.7 cm (2.6 in.)
  • Gravimetric Extractables
  • ≤30 mg after 24-h soak in water
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 3.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥9 L
  • Pore Size
  • 3.0 µm
  • Seal Material
  • Polyethylene (PE)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic
D030F3P01 Clarigard Cartridge Filter 30 in. 3.0 µm Code F PE 115 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code F double open end w/flat gaskets
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • D030F3P01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 6.7 cm (2.6 in.)
  • Gravimetric Extractables
  • ≤30 mg after 24-h soak in water
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 3.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥9 L
  • Pore Size
  • 3.0 µm
  • Seal Material
  • Polyethylene (PE)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic
XX6200004 Aerosol Adapter, Luer slip to 1/4 in.– 3/8 in. ID hose, stainless steel 117 
Add to Cart
  • Background Information
  • Millipore has a broad selection of fittings, adapters, valves, gauges, and tubing that can be used in conjunction with Millipore filtration systems. With stated exceptions, material of construction is Series 300 stainless steel.Tri-Clamp (TC) fittings are referred to by convention as 1 1/2", 2", etc. 1 1/2" TC fittings connect to 1" or 1 1/2" O.D. tube sizes. 2" TC fittings connect to 2" O.D. tube size only.
  • Catalogue Number
  • XX6200004
  • Diameter
  • 6.3 mm (0.25 in.) (I.D.)
  • Material Size
  • 1
  • Materials of Construction
  • Stainless steel
  • Sterility
  • Non-Sterile
KRA5A05FF1 Opticap® XL5 Polygard®-CR 0.5 µm 3/4 in. TC/TC 118 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Nominal Length
  • 5 in. (12.5 cm)
  • Catalogue Number
  • KRA5A05FF1
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Device Size
  • 5 in.
  • Diameter
  • 10.7 cm (4.2 in.)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Format
  • Single Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 30 mg per capsule after 24 hours in water at controlled room temperature.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 3/4 in.
  • Inlet to Outlet Width
  • 21.6 cm (8.5 in.)
  • Length
  • 5 in. (12.5 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 20 °C
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Polygard®-CR
  • Nominal Pore Size
  • 0.5 µm
  • Outlet Connection
  • Sanitary Flange
  • Outlet Connection Diameter
  • 3/4 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2.5 L
  • Pore Size
  • 0.5 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 3 autoclave cycles of 30 min @ 126 °C; not in-line steam sterilizable
  • Support Material
  • Polypropylene
  • Trade Name
  • Opticap®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Width
  • 21.6 cm (8.5 in.)
KRA5A05FF1 Opticap® XL5 Polygard®-CR 0.5 µm 3/4 in. TC/TC 118 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Nominal Length
  • 5 in. (12.5 cm)
  • Catalogue Number
  • KRA5A05FF1
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Device Size
  • 5 in.
  • Diameter
  • 10.7 cm (4.2 in.)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Format
  • Single Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 30 mg per capsule after 24 hours in water at controlled room temperature.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 3/4 in.
  • Inlet to Outlet Width
  • 21.6 cm (8.5 in.)
  • Length
  • 5 in. (12.5 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 20 °C
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Polygard®-CR
  • Nominal Pore Size
  • 0.5 µm
  • Outlet Connection
  • Sanitary Flange
  • Outlet Connection Diameter
  • 3/4 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2.5 L
  • Pore Size
  • 0.5 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 3 autoclave cycles of 30 min @ 126 °C; not in-line steam sterilizable
  • Support Material
  • Polypropylene
  • Trade Name
  • Opticap®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Width
  • 21.6 cm (8.5 in.)
KRA5A05HH1 Opticap® XL5 Polygard®-CR 0.5 µm 9/16 in. HB/HB 118 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Nominal Length
  • 5 in. (12.5 cm)
  • Catalogue Number
  • KRA5A05HH1
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Device Size
  • 5 in.
  • Diameter
  • 10.7 cm (4.2 in.)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Format
  • Single Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 30 mg per capsule after 24 hours in water at controlled room temperature.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Hose Barb
  • Inlet Connection Diameter
  • 9/16 in.
  • Inlet to Outlet Width
  • 21.6 cm (8.5 in.)
  • Length
  • 5 in. (12.5 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 20 °C
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Polygard®-CR
  • Nominal Pore Size
  • 0.5 µm
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 9/16 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2.5 L
  • Pore Size
  • 0.5 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 3 autoclave cycles of 30 min @ 126 °C; not in-line steam sterilizable
  • Support Material
  • Polypropylene
  • Trade Name
  • Opticap®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Width
  • 21.6 cm (8.5 in.)

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources