+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
SHVEA25NB6 Millipore Express® SHR w/Prefilter Optiscale® 25mm 0.5/0.1 µm NB 99 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Nominal Length
  • 1.52 in. (39 mm)
  • Catalogue Number
  • SHVEA25NB6
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Diameter
  • 3.1 cm (1.2 in.)
  • Filtration Area
  • 3.5 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Female Luer Lok
  • Length
  • 1.52 in. (39 mm)
  • Material Size
  • 6
  • Maximum Inlet Pressure, bar (psi)
  • 4.1 bar (60 psi) @ 25 °C
  • Media
  • Millipore Express® SHR w/Prefilter
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Male Luer Lok
  • Pore Size
  • 0.5 / 0.1 µm
  • Sterilization
  • 1 autoclave cycle of 60 min @ 123 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Wettability
  • Hydrophilic
SHVEA25NB6 Millipore Express® SHR w/Prefilter Optiscale® 25mm 0.5/0.1 µm NB 99 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Nominal Length
  • 1.52 in. (39 mm)
  • Catalogue Number
  • SHVEA25NB6
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Diameter
  • 3.1 cm (1.2 in.)
  • Filtration Area
  • 3.5 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Female Luer Lok
  • Length
  • 1.52 in. (39 mm)
  • Material Size
  • 6
  • Maximum Inlet Pressure, bar (psi)
  • 4.1 bar (60 psi) @ 25 °C
  • Media
  • Millipore Express® SHR w/Prefilter
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Male Luer Lok
  • Pore Size
  • 0.5 / 0.1 µm
  • Sterilization
  • 1 autoclave cycle of 60 min @ 123 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Wettability
  • Hydrophilic
SVEPA25NB6 Millipore Express® SHR Optiscale® 25mm 0.1 µm NB 99 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Nominal Length
  • 1.52 in. (39 mm)
  • Catalogue Number
  • SVEPA25NB6
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Diameter
  • 3.1 cm (1.2 in.)
  • Filtration Area
  • 3.5 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Female Luer Lok
  • Length
  • 1.52 in. (39 mm)
  • Material Size
  • 6
  • Maximum Inlet Pressure, bar (psi)
  • 4.1 bar (60 psi) @ 25 °C
  • Media
  • Millipore Express® SHR
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Male Luer Lok
  • Pore Size
  • 0.1 µm
  • Sterilization
  • 1 autoclave cycle of 60 min @ 123 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Wettability
  • Hydrophilic
SVEPA25NB6 Millipore Express® SHR Optiscale® 25mm 0.1 µm NB 99 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Nominal Length
  • 1.52 in. (39 mm)
  • Catalogue Number
  • SVEPA25NB6
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Diameter
  • 3.1 cm (1.2 in.)
  • Filtration Area
  • 3.5 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Female Luer Lok
  • Length
  • 1.52 in. (39 mm)
  • Material Size
  • 6
  • Maximum Inlet Pressure, bar (psi)
  • 4.1 bar (60 psi) @ 25 °C
  • Media
  • Millipore Express® SHR
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Male Luer Lok
  • Pore Size
  • 0.1 µm
  • Sterilization
  • 1 autoclave cycle of 60 min @ 123 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Wettability
  • Hydrophilic
SHGEA25NB6 Millipore Express® SHC Optiscale® 25mm 0.5/0.2 µm NB 100 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Nominal Length
  • 1.52 in. (39 mm)
  • Catalogue Number
  • SHGEA25NB6
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Diameter
  • 3.1 cm (1.2 in.)
  • Filtration Area
  • 3.5 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Female Luer Lok
  • Length
  • 1.52 in. (39 mm)
  • Material Size
  • 6
  • Maximum Inlet Pressure, bar (psi)
  • 4.1 bar (60 psi) @ 25 °C
  • Media
  • Millipore Express® SHC
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Male Luer Lok
  • Pore Size
  • 0.5 / 0.2 µm
  • Sterilization
  • 1 autoclave cycle of 60 min @ 123 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Wettability
  • Hydrophilic
SHGEA25NB6 Millipore Express® SHC Optiscale® 25mm 0.5/0.2 µm NB 100 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Nominal Length
  • 1.52 in. (39 mm)
  • Catalogue Number
  • SHGEA25NB6
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Diameter
  • 3.1 cm (1.2 in.)
  • Filtration Area
  • 3.5 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Female Luer Lok
  • Length
  • 1.52 in. (39 mm)
  • Material Size
  • 6
  • Maximum Inlet Pressure, bar (psi)
  • 4.1 bar (60 psi) @ 25 °C
  • Media
  • Millipore Express® SHC
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Male Luer Lok
  • Pore Size
  • 0.5 / 0.2 µm
  • Sterilization
  • 1 autoclave cycle of 60 min @ 123 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Wettability
  • Hydrophilic
D01001T01 Clarigard Cartridge Filter 10 in. 1.0 µm Code 0 PTFE-encapsulated Fluoroelastomer 101 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • D01001T01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤10 mg after 24-h soak in water
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 1.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L
  • Pore Size
  • 1.0 µm
  • Seal Material
  • Polytetrafluoroethylene (PTFE)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic
D01071T01 Clarigard Cartridge Filter 10 in. 1.0 µm Code 7 PTFE-encapsulated Fluoroelastomer 101 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • D01071T01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤10 mg after 24-h soak in water
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 1.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L
  • Pore Size
  • 1.0 µm
  • Seal Material
  • Polytetrafluoroethylene (PTFE)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic
YY2004057 Gasket, 1-1/2 in., PTFE-coated fluoroelastomer 102 
Add to Cart
  • Catalogue Number
  • YY2004057
  • Material Size
  • 10
YY3009053 O-rings, 90 mm filter housing, PTFE 102 
Add to Cart
  • Applicable Device
  • Stainless Steel Filter Holder, 90mm
  • Background Information
  • The Stainless steel filter holders are designed to ultraclean or sterilize liquids or gases by pressure filtration. PTFE-faced support screens permit autoclaving with membranes in place.YY3009000 Filter Holder, 90 mm, stainless steelReplacement Parts XX2504705 Hose Adapter, 1/4 in. NPTM to 3/8 in. I.D.XX4204708 Vent/Relief ValveYY3009053 O-rings, 90 mm filter housing, PTFEYY3009054 Support Screen, PTFE-coatedYY2209058 Underdrain Support, 90 mmYY2209059 Support Legs
  • Catalogue Number
  • YY3009053
  • Chemistry
  • Polytetrafluoroethylene (PTFE)
  • Material Size
  • 4

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources