+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
SP20A47FH3 Optiscale® Capsule Lifegard™ 2.0 µm 3/4 in. TC-1/4 in. HB 97 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Catalogue Number
  • SP20A47FH3
  • Chemistry
  • Borosilicate Glass Fiber (BGF)
  • Device Configuration
  • Capsule
  • Device Material
  • Polycarbonate
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filter Grade
  • AP20
  • Filtration Area
  • 17.7 cm²
  • Format
  • Single Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 3/4 in.
  • Material Size
  • 3
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 25 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Lifegard™
  • Nominal Pore Size
  • 2.0 µm
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 1/4 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥100 mL
  • Pore Size
  • 2.0 µm
  • Seal Material
  • Fluoroelastomer (FKM)
  • Sterilization
  • 3 autoclave cycles of 60 min @ 121 °C; not in-line steam sterilizable
  • Support Material
  • Polypropylene
  • Trade Name
  • OptiScale®
  • Vent Cap Material
  • Polyvinylidene fluoride (PVDF)
SVEPA47FF3 Millipore Express® SHR Optiscale® 47mm 0.1 µm 3/4 in. TC/TC 97 
Add to Cart
  • Cartridge Nominal Length
  • 2.91 in. (74 mm)
  • Catalogue Number
  • SVEPA47FF3
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Diameter
  • 3/4 in.
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 3/4 in.
  • Length
  • 2.91 in. (74 mm)
  • Material Size
  • 3
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SHR
  • Outlet Connection
  • Sanitary Flange
  • Outlet Connection Diameter
  • 3/4 in.
  • Pore Size
  • 0.1 µm
  • Trade Name
  • Millipore Express®
  • Wettability
  • Hydrophilic
SVEPA47FH3 Millipore Express® SHR Optiscale® 47mm 0.1 µm 3/4 in. TC-1/4 in. HB 97 
Add to Cart
  • Cartridge Nominal Length
  • 3.24 in. (82 mm)
  • Catalogue Number
  • SVEPA47FH3
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Diameter
  • 3/4 in.
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 3/4 in.
  • Length
  • 3.24 in. (82 mm)
  • Material Size
  • 3
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SHR
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 1/4 in.
  • Pore Size
  • 0.1 µm
  • Trade Name
  • Millipore Express®
  • Wettability
  • Hydrophilic
D00501S01 Clarigard Cartridge Filter 10 in. 0.5 µm Code 0 Silicone 98 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • D00501S01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤10 mg after 24-h soak in water
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.5 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L
  • Pore Size
  • 0.5 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic
D00501S01 Clarigard Cartridge Filter 10 in. 0.5 µm Code 0 Silicone 98 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • D00501S01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤10 mg after 24-h soak in water
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.5 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L
  • Pore Size
  • 0.5 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic
D00571E01 Clarigard Cartridge Filter 10 in. 0.5 µm Code 7 Ethylene-Propylene 98 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • D00571E01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤10 mg after 24-h soak in water
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.5 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L
  • Pore Size
  • 0.5 µm
  • Seal Material
  • Ethylene Propylene
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic
D00571S01 Clarigard Cartridge Filter 10 in. 0.5 µm Code 7 Silicone 98 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • D00571S01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤10 mg after 24-h soak in water
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.5 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L
  • Pore Size
  • 0.5 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic
D00571S01 Clarigard Cartridge Filter 10 in. 0.5 µm Code 7 Silicone 98 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • D00571S01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤10 mg after 24-h soak in water
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.5 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L
  • Pore Size
  • 0.5 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic
SGEPA25NB6 Millipore Express® SHF Optiscale® 25mm 0.2 µm NB 99 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Nominal Length
  • 1.52 in. (39 mm)
  • Catalogue Number
  • SGEPA25NB6
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Diameter
  • 3.1 cm (1.2 in.)
  • Filtration Area
  • 3.5 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Female Luer Lok
  • Length
  • 1.52 in. (39 mm)
  • Material Size
  • 6
  • Maximum Inlet Pressure, bar (psi)
  • 4.1 bar (60 psi) @ 25 °C
  • Media
  • Millipore Express® SHF
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Male Luer Lok
  • Pore Size
  • 0.2 µm
  • Sterilization
  • 1 autoclave cycle of 60 min @ 123 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Wettability
  • Hydrophilic
SGEPA25NB6 Millipore Express® SHF Optiscale® 25mm 0.2 µm NB 99 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Nominal Length
  • 1.52 in. (39 mm)
  • Catalogue Number
  • SGEPA25NB6
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Diameter
  • 3.1 cm (1.2 in.)
  • Filtration Area
  • 3.5 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Female Luer Lok
  • Length
  • 1.52 in. (39 mm)
  • Material Size
  • 6
  • Maximum Inlet Pressure, bar (psi)
  • 4.1 bar (60 psi) @ 25 °C
  • Media
  • Millipore Express® SHF
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Male Luer Lok
  • Pore Size
  • 0.2 µm
  • Sterilization
  • 1 autoclave cycle of 60 min @ 123 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Wettability
  • Hydrophilic

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources