We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.
AMICON ULTRA-15 15ML - 3 KDa cutoff. Available in 3 pack sizes. UFC900308 - 8 pack UFC900324 - 24 pack UFC900396 - 96 pack High recovery Ultracel regenerated cellulose membrane in a range of molecular weight cut-offs High retentate recovery of greater than 90% Vertical membrane reduces concentration polarization for ultra-fast spin times (as fast as 10–15 minutes) Heat-sealed membrane minimizes downstream extractables 100% integrity tested for reliable performance Convenient sample monitoring with translucent housing and volume gradations Direct pipettor sample access eliminates processing step to recover concentrate High concentration factors of 80–100X Applications: Concentration of biological samples containing antigens, antibodies, enzymes, nucleic acids, or microorganisms Purification of macromolecular components found in tissue culture extracts or cell lysates and protein removal prior to HPLS Concentration of dilute or pre-purified proteins from column eluents Desalting, buffer exchange and protein dialysis
Catalogue Number
UFC900396
Centrifugal Application
Protein Concentration and Desalting
Chemistry
Regenerated Cellulose (RC)
Color Code
Clear with pink cap
Device Material
Housing: Styrene/butadieneTube: PolypropyleneCap and liner: Polyethylene
AMICON ULTRA-15 15ML - 3 KDa cutoff. Available in 3 pack sizes. UFC900308 - 8 pack UFC900324 - 24 pack UFC900396 - 96 pack High recovery Ultracel regenerated cellulose membrane in a range of molecular weight cut-offs High retentate recovery of greater than 90% Vertical membrane reduces concentration polarization for ultra-fast spin times (as fast as 10–15 minutes) Heat-sealed membrane minimizes downstream extractables 100% integrity tested for reliable performance Convenient sample monitoring with translucent housing and volume gradations Direct pipettor sample access eliminates processing step to recover concentrate High concentration factors of 80–100X Applications: Concentration of biological samples containing antigens, antibodies, enzymes, nucleic acids, or microorganisms Purification of macromolecular components found in tissue culture extracts or cell lysates and protein removal prior to HPLS Concentration of dilute or pre-purified proteins from column eluents Desalting, buffer exchange and protein dialysis
Catalogue Number
UFC900396
Centrifugal Application
Protein Concentration and Desalting
Chemistry
Regenerated Cellulose (RC)
Color Code
Clear with pink cap
Device Material
Housing: Styrene/butadieneTube: PolypropyleneCap and liner: Polyethylene
Amicon Ultra 2ml 3K 24PK Concentrates 2 mL down to 15-70 µl 98% sample recovery Fast processing time - 10 to 30 minute spin times Engineered dead stop Reverse spin capability provides consistent recoveries Applications: Concentration of biological samples containing antigens, antibodies, enzymes, nucleic acids, or microorganisms Purification of macromolecular components found in tissue culture extracts or cell lysates Primer removal, PCR cleanup, removal of linkers or macromolecular labels from a reaction mix, and protein removal prior to HPLC Desalting, buffer exchange and protein dialysis Material Supplied: The Amicon® Ultra-2 device is supplied with two microcentrifuge tubes. During operation, one tube is used to collect filtrate; the other tube is to recover the concentrated sample.
Amicon Ultra 2ml 3K 24PK Concentrates 2 mL down to 15-70 µl 98% sample recovery Fast processing time - 10 to 30 minute spin times Engineered dead stop Reverse spin capability provides consistent recoveries Applications: Concentration of biological samples containing antigens, antibodies, enzymes, nucleic acids, or microorganisms Purification of macromolecular components found in tissue culture extracts or cell lysates Primer removal, PCR cleanup, removal of linkers or macromolecular labels from a reaction mix, and protein removal prior to HPLC Desalting, buffer exchange and protein dialysis Material Supplied: The Amicon® Ultra-2 device is supplied with two microcentrifuge tubes. During operation, one tube is used to collect filtrate; the other tube is to recover the concentrated sample.
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
MD0HC10FS27NA
Chemistry
Cellulose (CL)Inorganic Filter Aid
Device Configuration
multilayer Pod
Device Material
Glass fiber reinforced polypropylene
Filter Grade
D0HC
Filtration Area
1.1 m²
Gravimetric Extractables
After 24 hour static soak in pure water (Type 1 DI Water) post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 100 L/m2 of media surface area: 39 – 69 mg/m2
Height
32 cm (12.5 in.)
Length
62 cm (24.2 in.)
Material Size
1
Maximum Differential Pressure, bar (psid)
Forward: 2.1 bar (30 psid) @ 25 °C; 1 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C
Ion-Exchange Resin with 26 g/L ion exchange capacity
Material Size
1
Overview
SynergyPak® cartridge produces ultrapure (Type 1) water when the Synergy® water system is fed with DI (non-particulate-free) water. The cartridge uses key purification technologies such as activated carbon, ion-exchange resin, and depth filtration to purify water. As the final step, the pretreated water is purified at the point-of-dispense by removing trace contaminants. The cartridge should be periodically replaced. The "plug-and-use" design facilitates easy and rapid replacement.
ROPAK® RO System Double-sided Pretreatment Pack protects the reverse osmosis (RO) membrane by efficiently removing most large particles, organic compounds, and chlorine from tap water. Designed for use with AFS®, Milli-RO™, Milli-RX, and Milli-U water purification systems.
The Progard® 2 Pretreatment Pack protects the reverse osmosis (RO) membrane from organic fouling and chlorine oxidation by removing large particles, organic compounds, and free chlorine from tap water. The pack contains natural activated carbon and a depth filter for water pretreatment. For use with Eli®and RiOs™ 5/8/16 water purification systems. It is suitable for tap water feed with silt density index (SDI) 2 < 3 ppm, and TOC < 2000 ppb. The pack ensures that your system lifetime and performance are optimized.
The Progard® T3 pretreatment pack pretreats tap water by removing large particles, organic compounds and free chlorine. This pack optimizes system lifetime by protecting the reverse osmosis (RO) membrane against organic fouling, chlorine oxidation, and mineral scaling. This pack includes polyphosphates, activated carbon and a depth filter for water pretreatment. The pack is suitable for tap water feed with silt density index (SDI) 2 ® Direct systems.
This redesigned Vent Filter protects pure water stored in Milli-Q® IQ/IX storage tanks from airborne contaminants, such as CO2, organic compounds, particles, and micro-organisms. The vent filter is seamlessly integrated at the top of the storage tank for easy replacement and an easier fit. To protect stored pure water, the vent filter includes: soda lime to remove CO2, activated carbon to absorb volatile organics, and hydrophobic membrane to retain particles and bacteria. For use with Milli-Q® IQ & IX 7003/05/10/15 water purification systems.
Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.
Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.