+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
MC0HC10FS1 Millistak+® HC Pod Depth Filter, C0HC media series, 1.1 m2 surface area 496 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
  • Catalogue Number
  • MC0HC10FS1
  • Chemistry
  • Cellulose (CL)Inorganic Filter Aid
  • Device Configuration
  • Pod
  • Device Material
  • Glass fiber reinforced polypropylene
  • Filter Grade
  • C0HC
  • Filtration Area
  • 1.1 m²
  • Gravimetric Extractables
  • After 24 hour static soak in pure water (Type 1 DI Water) post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 100 L/m2 of media surface area: 39 – 69 mg/m2
  • Height
  • 32 cm (12.5 in.)
  • Length
  • 62 cm (24.2 in.)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 2.1 bar (30 psid) @ 25 °C; 1 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 3.5 bar (50 psi) @ 25 °C; 1 bar (15 psi) @ 80 °C
  • Sterilization
  • 1 autoclave cycle of 60 min @ 123 °C
  • Trade Name
  • Millistak+®
  • Wettability
  • Hydrophilic
LC0HCG6S2 Millistak+® Lenticular Disc Filters, C0HC media series, 16 in. diameter, 8-cell, silicone seal, 2/pack 844 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
  • Catalogue Number
  • LC0HCG6S2
  • Chemistry
  • Cellulose (CL)Inorganic Filter AidMixed Cellulose Esters (MCE)
  • Device Configuration
  • Stack Disk
  • Device Material
  • Polypropylene
  • Diameter
  • 40.64 cm (16 in.)
  • Filter Grade
  • DE30 / DE60
  • Filtration Area
  • 1.8 m²
  • Gravimetric Extractables
  • Post autoclave (1 cycle of 30 minutes at 123 °C) and pure water flush of 100 L/m2 (10 L/ft2) of media surface area.NVR: 1.50 – 2.02 mg/m2TOC: 416– 593 ppb
  • Material Size
  • 2
  • Maximum Differential Pressure, bar (psid)
  • Forward: 2.07 bar (30 psid) @ 25 °C; 1.03 bar (15 psid) @ 80 °C; 0.21 bar (3 psid) @ 123 °C. Reverse: 0.03 bar (0.5 psid)
  • Maximum Inlet Pressure, bar (psi)
  • 2.1 bar (30 psi) @ 25 °C; 1 bar (15 psi) @ 80 °C; 0.2 bar (3 psi) @ 123 °C
  • Oxidizable Substances
  • The effluent of an autoclaved (1 cycle of 30 minutes @ 123 °C) stacked device is negative after a WFI flush of 10 liters per ft2 (100 L/m2) of media surface area
  • Sanitization
  • May be hot water sanitized for 20 cycles using purified water @ 80 °C for 30 minutes
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • May be steam sterilized for 3 steam-in-place (SIP) cycles of 30 minutes @ 123 °C
  • Trade Name
  • Millistak+®
  • Wettability
  • Hydrophilic
LC0HCG6S2 Millistak+® Lenticular Disc Filters, C0HC media series, 16 in. diameter, 8-cell, silicone seal, 2/pack 844 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
  • Catalogue Number
  • LC0HCG6S2
  • Chemistry
  • Cellulose (CL)Inorganic Filter AidMixed Cellulose Esters (MCE)
  • Device Configuration
  • Stack Disk
  • Device Material
  • Polypropylene
  • Diameter
  • 40.64 cm (16 in.)
  • Filter Grade
  • DE30 / DE60
  • Filtration Area
  • 1.8 m²
  • Gravimetric Extractables
  • Post autoclave (1 cycle of 30 minutes at 123 °C) and pure water flush of 100 L/m2 (10 L/ft2) of media surface area.NVR: 1.50 – 2.02 mg/m2TOC: 416– 593 ppb
  • Material Size
  • 2
  • Maximum Differential Pressure, bar (psid)
  • Forward: 2.07 bar (30 psid) @ 25 °C; 1.03 bar (15 psid) @ 80 °C; 0.21 bar (3 psid) @ 123 °C. Reverse: 0.03 bar (0.5 psid)
  • Maximum Inlet Pressure, bar (psi)
  • 2.1 bar (30 psi) @ 25 °C; 1 bar (15 psi) @ 80 °C; 0.2 bar (3 psi) @ 123 °C
  • Oxidizable Substances
  • The effluent of an autoclaved (1 cycle of 30 minutes @ 123 °C) stacked device is negative after a WFI flush of 10 liters per ft2 (100 L/m2) of media surface area
  • Sanitization
  • May be hot water sanitized for 20 cycles using purified water @ 80 °C for 30 minutes
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • May be steam sterilized for 3 steam-in-place (SIP) cycles of 30 minutes @ 123 °C
  • Trade Name
  • Millistak+®
  • Wettability
  • Hydrophilic
LC0HCH6S6 Millistak+® Lenticular Disc Filters, C0HC media series, 16 in. diameter, 2-cell, silicone seal, 6/pack 970 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
  • Catalogue Number
  • LC0HCH6S6
  • Chemistry
  • Cellulose (CL)Inorganic Filter AidMixed Cellulose Esters (MCE)
  • Device Configuration
  • Stack Disk
  • Device Material
  • Polypropylene
  • Diameter
  • 40.64 cm (16 in.)
  • Filter Grade
  • DE30 / DE60
  • Filtration Area
  • 0.45 m²
  • Height
  • 5.94 cm (2.34 in.)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • Forward: 2.07 bar (30 psid) @ 25 °C; 1.03 bar (15 psid) @ 80 °C; 0.21 bar (3 psid) @ 123 °C. Reverse: 0.03 bar (0.5 psid)
  • Oxidizable Substances
  • The effluent of an autoclaved (1 cycle of 30 minutes @ 123 °C) stacked device is negative after a WFI flush of 10 liters per ft2 (100 L/m2) of media surface area
  • Sanitization
  • May be hot water sanitized for 20 cycles using purified water @ 80 °C for 30 minutes
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • May be steam sterilized for 3 steam-in-place (SIP) cycles of 30 minutes @ 123 °C
  • Trade Name
  • Millistak+®
  • Wettability
  • Hydrophilic
MC0HC10FS27EU Millistak+® HC Pod Depth Filter, C0HC media series, 1.1 m2 surface area, 27/pack shipped on a European CP-2 standard sized pallet 14697 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
  • Catalogue Number
  • MC0HC10FS27EU
  • Chemistry
  • Cellulose (CL)Inorganic Filter Aid
  • Device Configuration
  • multilayer Pod
  • Device Material
  • Glass fiber reinforced polypropylene
  • Filter Grade
  • C0HC
  • Filtration Area
  • 1.1 m²
  • Gravimetric Extractables
  • After 24 hour static soak in pure water (Type 1 DI Water) post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 100 L/m2 of media surface area: 39 – 69 mg/m2
  • Height
  • 32 cm (12.5 in.)
  • Length
  • 62 cm (24.2 in.)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 2.1 bar (30 psid) @ 25 °C; 1 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 3.5 bar (50 psi) @ 25 °C; 1 bar (15 psi) @ 80 °C
  • Sterilization
  • 1 autoclave cycle of 60 min @ 123 °C
  • Trade Name
  • Millistak+®
  • Wettability
  • Hydrophilic
MC0HC10FS27NA Millistak+® HC Pod Depth Filter, C0HC media series, 1.1 m2 surface area, 27/pack shipped on a North American standard sized pallet Special offer 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
  • Catalogue Number
  • MC0HC10FS27NA
  • Chemistry
  • Cellulose (CL)Inorganic Filter Aid
  • Device Configuration
  • multilayer Pod
  • Device Material
  • Glass fiber reinforced polypropylene
  • Filter Grade
  • C0HC
  • Filtration Area
  • 1.1 m²
  • Gravimetric Extractables
  • After 24 hour static soak in pure water (Type 1 DI Water) post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 100 L/m2 of media surface area: 39 – 69 mg/m2
  • Height
  • 32 cm (12.5 in.)
  • Length
  • 62 cm (24.2 in.)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 2.1 bar (30 psid) @ 25 °C; 1 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 3.5 bar (50 psi) @ 25 °C; 1 bar (15 psi) @ 80 °C
  • Sterilization
  • 1 autoclave cycle of 60 min @ 123 °C
  • Trade Name
  • Millistak+®
  • Wettability
  • Hydrophilic
MSP010063 Petri-Pad™ Petri dish, sterile, 47 mm, EO sterilized for m-ColiBlue® 63 
Add to Cart
  • Catalogue Number
  • MSP010063
  • Chemistry
  • Polystyrene (PS)Cellulose Pad
  • Device Material
  • Not applicable
  • Diameter
  • 47 mm
  • Filter Color
  • Not applicable
  • Filter Diameter (⌀)
  • Not applicable
  • Filter Surface
  • Not applicable
  • Key Applications
  • EnvironmentalFood and Beverage
  • Material Size
  • 150
  • Overview
  • 47 mm petri pad dishes for filter cultures on broth
  • Pore Size
  • Not applicable
  • Sterility
  • Sterile
  • Trade Name
  • Not applicable
  • Volume
  • Not applicable
MK42600 Ultrafree-DA Centrifugal Filter Unit 92 
Add to Cart
  • Catalogue Number
  • 42600
  • Centrifugal Application
  • DNA Gel Extraction
  • Chemistry
  • Polypropylene (PP)
  • Color Code
  • Blue
  • Device Material
  • Polypropylene
  • Diameter
  • 10.7 mm
  • Filter Type
  • Microfiltration
  • Filtration Area
  • 0.2 cm²
  • Key Applications
  • DNA Extraction
  • Length
  • 45 mm
  • Material Size
  • 50
  • Maximum Operating Temperature
  • 50 °C
  • Overview
  • Recover 100 to 10,000 bp DNA from agarose gel slices in a single 10-minute spin. The kit consists of a pre-assembled filter device with an agarose gel nebulizer, a microcentrifuge vial, and modified TAE gel extraction buffer (dry).The device utilizes gel compression to extract DNA from the agarose. Centrifugal force collapses the gel structure, drives the agarose through a small orifice in the gel nebulizer and the resultant gel slurry is sprayed into the sample filter cup.Prepared DNA requires no further purification for most applications, including cloning and radioisotopic or fluorescent DNA sequencing. Since agarose gel electrophoresis has high resolving power, the small and large non-specific amplification products that frequently interfere with cloning and sequencing after PCR are completely removed from the product. Minimal hands-on time 10-minute spin Fully-functional DNA PerformanceTypical DNA Recoveries from Agarose Gels DNA Size (bp) Percent DNA Recoveries 100 78 700 71 1000 77 2027 47 4361 35 9416 32 23130 29Protocol1. Excise the band of interest after routine electrophoretic analysis of PCR products or other DNA through an agarose gel.2. Place the gel slice into the pre-assembled device. Note: Protocol is not compatible with low melting point agarose.3. Spin at 5,000 x g for 10 minutes to extract gel slurry into filter cup.4. DNA can be stored in the capped filtrate vial after discarding the sample filter cup and gel nebulizer.
  • Pore Size
  • Not Applicable
  • Sterility
  • Non-Sterile
  • Trade Name
  • Ultrafree
  • Volume
  • 0.5 mL
MB1HC027H1 Millistak+® HC Pod Depth Filter, B1HC media series, 0.027 m2 surface area, 1/4 in. Hose Barb connection 133 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
  • Catalogue Number
  • MB1HC027H1
  • Chemistry
  • Cellulose (CL)Inorganic Filter AidMixed Cellulose Esters (MCE)
  • Device Configuration
  • lab scale Pod
  • Device Material
  • Glass fiber reinforced polypropylene
  • Filter Grade
  • B1HC
  • Filtration Area
  • 0.027 m²
  • Gravimetric Extractables
  • After 24 hour static soak in pure water (Type 1 DI Water) post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 100 L/m2 of media surface area: 39–69 mg/m2
  • Height
  • 14 cm (5.3 in.)
  • Length
  • 22 cm (8.5 in.)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 2.1 bar (30 psid) @ 25 °C; 1 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 3.5 bar (50 psi) @ 25 °C; 1 bar (15 psi) @ 80 °C
  • Sterilization
  • 1 autoclave cycle of 60 min @ 123 ºC
  • Trade Name
  • Millistak+®
  • Wettability
  • Hydrophilic
MB1HC027H1 Millistak+® HC Pod Depth Filter, B1HC media series, 0.027 m2 surface area, 1/4 in. Hose Barb connection 133 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
  • Catalogue Number
  • MB1HC027H1
  • Chemistry
  • Cellulose (CL)Inorganic Filter AidMixed Cellulose Esters (MCE)
  • Device Configuration
  • lab scale Pod
  • Device Material
  • Glass fiber reinforced polypropylene
  • Filter Grade
  • B1HC
  • Filtration Area
  • 0.027 m²
  • Gravimetric Extractables
  • After 24 hour static soak in pure water (Type 1 DI Water) post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 100 L/m2 of media surface area: 39–69 mg/m2
  • Height
  • 14 cm (5.3 in.)
  • Length
  • 22 cm (8.5 in.)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 2.1 bar (30 psid) @ 25 °C; 1 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 3.5 bar (50 psi) @ 25 °C; 1 bar (15 psi) @ 80 °C
  • Sterilization
  • 1 autoclave cycle of 60 min @ 123 ºC
  • Trade Name
  • Millistak+®
  • Wettability
  • Hydrophilic

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources