+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
MA1HC054H1 Millistak+® HC Pod Depth Filter, A1HC media series, 0.054 m2 surface area, 1/4 in. Hose Barb connection 174 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
  • Catalogue Number
  • MA1HC054H1
  • Chemistry
  • Cellulose (CL)Inorganic Filter AidMixed Cellulose Esters (MCE)
  • Device Configuration
  • lab scale Pod
  • Device Material
  • Glass fiber reinforced polypropylene
  • Filter Grade
  • A1HC
  • Filtration Area
  • 0.054 m²
  • Gravimetric Extractables
  • After 24 hour static soak in pure water (Type 1 DI Water) post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 100 L/m2 of media surface area: 39–69 mg/m2
  • Height
  • 14 cm (5.3 in.)
  • Length
  • 22 cm (8.5 in.)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 2.1 bar (30 psid) @ 25 °C; 1 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 3.5 bar (50 psi) @ 25 °C; 1 bar (15 psi) @ 80 °C
  • Sterilization
  • 1 autoclave cycle of 60 min @ 123 ºC
  • Trade Name
  • Millistak+®
  • Wettability
  • Hydrophilic
MA1HC01FS1 Millistak+® HC Pod Depth Filter, A1HC media series, 0.11 m2 surface area 220 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
  • Catalogue Number
  • MA1HC01FS1
  • Chemistry
  • Cellulose (CL)Inorganic Filter AidMixed Cellulose Esters (MCE)
  • Device Configuration
  • Pod
  • Device Material
  • Glass fiber reinforced polypropylene
  • Filter Grade
  • A1HC
  • Filtration Area
  • 0.11 m²
  • Gravimetric Extractables
  • After 24 hour static soak in pure water (Type 1 DI Water) post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 100 L/m2 of media surface area: 39 – 69 mg/m2
  • Height
  • 32 cm (12.5 in.)
  • Length
  • 62 cm (24.2 in.)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 2.1 bar (30 psid) @ 25 °C; 1 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 3.5 bar (50 psi) @ 25 °C; 1 bar (15 psi) @ 80 °C
  • Sterilization
  • 1 autoclave cycle of 60 min @ 123 °C
  • Trade Name
  • Millistak+®
  • Wettability
  • Hydrophilic
MA1HC01FS1 Millistak+® HC Pod Depth Filter, A1HC media series, 0.11 m2 surface area 220 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
  • Catalogue Number
  • MA1HC01FS1
  • Chemistry
  • Cellulose (CL)Inorganic Filter AidMixed Cellulose Esters (MCE)
  • Device Configuration
  • Pod
  • Device Material
  • Glass fiber reinforced polypropylene
  • Filter Grade
  • A1HC
  • Filtration Area
  • 0.11 m²
  • Gravimetric Extractables
  • After 24 hour static soak in pure water (Type 1 DI Water) post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 100 L/m2 of media surface area: 39 – 69 mg/m2
  • Height
  • 32 cm (12.5 in.)
  • Length
  • 62 cm (24.2 in.)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 2.1 bar (30 psid) @ 25 °C; 1 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 3.5 bar (50 psi) @ 25 °C; 1 bar (15 psi) @ 80 °C
  • Sterilization
  • 1 autoclave cycle of 60 min @ 123 °C
  • Trade Name
  • Millistak+®
  • Wettability
  • Hydrophilic
MA1HC05FS1 Millistak+® HC Pod Depth Filter, A1HC media series, 0.55 m2 surface area 341 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
  • Catalogue Number
  • MA1HC05FS1
  • Chemistry
  • Cellulose (CL)Inorganic Filter AidMixed Cellulose Esters (MCE)
  • Device Configuration
  • Pod
  • Device Material
  • Glass fiber reinforced polypropylene
  • Filter Grade
  • A1HC
  • Filtration Area
  • 0.55 m²
  • Gravimetric Extractables
  • After 24 hour static soak in pure water (Type 1 DI Water) post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 100 L/m2 of media surface area: 39 – 69 mg/m2
  • Height
  • 32 cm (12.5 in.)
  • Length
  • 62 cm (24.2 in.)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 2.1 bar (30 psid) @ 25 °C; 1 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 3.5 bar (50 psi) @ 25 °C; 1 bar (15 psi) @ 80 °C
  • Sterilization
  • 1 autoclave cycle of 60 min @ 123 °C
  • Trade Name
  • Millistak+®
  • Wettability
  • Hydrophilic
MA1HC05FS1 Millistak+® HC Pod Depth Filter, A1HC media series, 0.55 m2 surface area 341 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
  • Catalogue Number
  • MA1HC05FS1
  • Chemistry
  • Cellulose (CL)Inorganic Filter AidMixed Cellulose Esters (MCE)
  • Device Configuration
  • Pod
  • Device Material
  • Glass fiber reinforced polypropylene
  • Filter Grade
  • A1HC
  • Filtration Area
  • 0.55 m²
  • Gravimetric Extractables
  • After 24 hour static soak in pure water (Type 1 DI Water) post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 100 L/m2 of media surface area: 39 – 69 mg/m2
  • Height
  • 32 cm (12.5 in.)
  • Length
  • 62 cm (24.2 in.)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 2.1 bar (30 psid) @ 25 °C; 1 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 3.5 bar (50 psi) @ 25 °C; 1 bar (15 psi) @ 80 °C
  • Sterilization
  • 1 autoclave cycle of 60 min @ 123 °C
  • Trade Name
  • Millistak+®
  • Wettability
  • Hydrophilic
MA1HC10FS1 Millistak+® HC Pod Depth Filter, A1HC media series, 1.1 m2 surface area 496 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
  • Catalogue Number
  • MA1HC10FS1
  • Chemistry
  • Cellulose (CL)Inorganic Filter AidMixed Cellulose Esters (MCE)
  • Device Configuration
  • Pod
  • Device Material
  • Glass fiber reinforced polypropylene
  • Filter Grade
  • A1HC
  • Filtration Area
  • 1.1 m²
  • Gravimetric Extractables
  • After 24 hour static soak in pure water (Type 1 DI Water) post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 100 L/m2 of media surface area: 39 – 69 mg/m2
  • Height
  • 32 cm (12.5 in.)
  • Length
  • 62 cm (24.2 in.)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 2.1 bar (30 psid) @ 25 °C; 1 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 3.5 bar (50 psi) @ 25 °C; 1 bar (15 psi) @ 80 °C
  • Sterilization
  • 1 autoclave cycle of 60 min @ 123 °C
  • Trade Name
  • Millistak+®
  • Wettability
  • Hydrophilic
MA1HC10FS1 Millistak+® HC Pod Depth Filter, A1HC media series, 1.1 m2 surface area 496 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
  • Catalogue Number
  • MA1HC10FS1
  • Chemistry
  • Cellulose (CL)Inorganic Filter AidMixed Cellulose Esters (MCE)
  • Device Configuration
  • Pod
  • Device Material
  • Glass fiber reinforced polypropylene
  • Filter Grade
  • A1HC
  • Filtration Area
  • 1.1 m²
  • Gravimetric Extractables
  • After 24 hour static soak in pure water (Type 1 DI Water) post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 100 L/m2 of media surface area: 39 – 69 mg/m2
  • Height
  • 32 cm (12.5 in.)
  • Length
  • 62 cm (24.2 in.)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 2.1 bar (30 psid) @ 25 °C; 1 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 3.5 bar (50 psi) @ 25 °C; 1 bar (15 psi) @ 80 °C
  • Sterilization
  • 1 autoclave cycle of 60 min @ 123 °C
  • Trade Name
  • Millistak+®
  • Wettability
  • Hydrophilic
LA1HCG6S2 Millistak+® Lenticular Disc Filters, A1HC media series, 16 in. diameter, 8-cell, silicone seal, 2/pack 907 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
  • Catalogue Number
  • LA1HCG6S2
  • Chemistry
  • Cellulose (CL)Inorganic Filter AidMixed Cellulose Esters (MCE)
  • Device Configuration
  • Stack Disk
  • Device Material
  • Polypropylene
  • Diameter
  • 40.64 cm (16 in.)
  • Filter Grade
  • A1HC
  • Filtration Area
  • 1.8 m²
  • Gravimetric Extractables
  • Post autoclave (1 cycle of 30 minutes at 123 °C) and pure water flush of 100 L/m2 (10 L/ft2) of media surface area.NVR: 1.50 – 2.02 mg/m2TOC: 416– 593 ppb
  • Material Size
  • 2
  • Maximum Differential Pressure, bar (psid)
  • Forward: 2.07 bar (30 psid) @ 25 °C; 1.03 bar (15 psid) @ 80 °C; 0.21 bar (3 psid) @ 123 °C. Reverse: 0.03 bar (0.5 psid)
  • Maximum Inlet Pressure, bar (psi)
  • 2.1 bar (30 psi) @ 25 °C; 1 bar (15 psi) @ 80 °C; 0.2 bar (3 psi) @ 123 °C
  • Oxidizable Substances
  • The effluent of an autoclaved (1 cycle of 30 minutes @ 123 °C) stacked device is negative after a WFI flush of 10 liters per ft2 (100 L/m2) of media surface area
  • Sanitization
  • May be hot water sanitized for 20 cycles using purified water @ 80 °C for 30 minutes
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • May be steam sterilized for 3 steam-in-place (SIP) cycles of 30 minutes @ 123 °C
  • Trade Name
  • Millistak+®
  • Wettability
  • Hydrophilic
LA1HCG6S2 Millistak+® Lenticular Disc Filters, A1HC media series, 16 in. diameter, 8-cell, silicone seal, 2/pack 907 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
  • Catalogue Number
  • LA1HCG6S2
  • Chemistry
  • Cellulose (CL)Inorganic Filter AidMixed Cellulose Esters (MCE)
  • Device Configuration
  • Stack Disk
  • Device Material
  • Polypropylene
  • Diameter
  • 40.64 cm (16 in.)
  • Filter Grade
  • A1HC
  • Filtration Area
  • 1.8 m²
  • Gravimetric Extractables
  • Post autoclave (1 cycle of 30 minutes at 123 °C) and pure water flush of 100 L/m2 (10 L/ft2) of media surface area.NVR: 1.50 – 2.02 mg/m2TOC: 416– 593 ppb
  • Material Size
  • 2
  • Maximum Differential Pressure, bar (psid)
  • Forward: 2.07 bar (30 psid) @ 25 °C; 1.03 bar (15 psid) @ 80 °C; 0.21 bar (3 psid) @ 123 °C. Reverse: 0.03 bar (0.5 psid)
  • Maximum Inlet Pressure, bar (psi)
  • 2.1 bar (30 psi) @ 25 °C; 1 bar (15 psi) @ 80 °C; 0.2 bar (3 psi) @ 123 °C
  • Oxidizable Substances
  • The effluent of an autoclaved (1 cycle of 30 minutes @ 123 °C) stacked device is negative after a WFI flush of 10 liters per ft2 (100 L/m2) of media surface area
  • Sanitization
  • May be hot water sanitized for 20 cycles using purified water @ 80 °C for 30 minutes
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • May be steam sterilized for 3 steam-in-place (SIP) cycles of 30 minutes @ 123 °C
  • Trade Name
  • Millistak+®
  • Wettability
  • Hydrophilic
LA1HCH6S6 Millistak+® Lenticular Disc Filters, A1HC media series, 16 in. diameter, 2-cell, silicone seal, 6/pack 1097 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
  • Catalogue Number
  • LA1HCH6S6
  • Chemistry
  • Cellulose (CL)Inorganic Filter AidMixed Cellulose Esters (MCE)
  • Device Configuration
  • Stack Disk
  • Device Material
  • Polypropylene
  • Diameter
  • 40.64 cm (16 in.)
  • Filter Grade
  • A1HC
  • Filtration Area
  • 0.45 m²
  • Height
  • 5.94 cm (2.34 in.)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • Forward: 2.07 bar (30 psid) @ 25 °C; 1.03 bar (15 psid) @ 80 °C; 0.21 bar (3 psid) @ 123 °C. Reverse: 0.03 bar (0.5 psid)
  • Oxidizable Substances
  • The effluent of an autoclaved (1 cycle of 30 minutes @ 123 °C) stacked device is negative after a WFI flush of 10 liters per ft2 (100 L/m2) of media surface area
  • Sanitization
  • May be hot water sanitized for 20 cycles using purified water @ 80 °C for 30 minutes
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • May be steam sterilized for 3 steam-in-place (SIP) cycles of 30 minutes @ 123 °C
  • Trade Name
  • Millistak+®
  • Wettability
  • Hydrophilic

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources