We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.
Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Nominal Length
34.3 in. (87.1 cm)
Catalogue Number
KPHLG3TTT1
Chemistry
Polyvinylidene Fluoride (PVDF)
Device Configuration
Capsule
Device Material
Polypropylene
Device Size
30 in.
Diameter
10.7 cm (4.2 in.)
Filtration Area
1.86 m²
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 25 mg per capsule after 24 hours in water at controlled room temperature.
Housing Material
Polypropylene (PP)
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Sanitary Flange
Inlet Connection Diameter
1-1/2 in.
Inlet to Outlet Width
87.1 cm (34.3 in.)
Length
34.3 in. (87.1 cm)
Material Size
1
Maximum Differential Pressure, bar (psid)
Forward: 4.1 bar (60 psid) @25 ˚C. Reverse: 2.1 bar (30 psid) @ 4-40 °C
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 23 °C; 2.8 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Durapore®
Non-Fiber Releasing
This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Sanitary Flange
Outlet Connection Diameter
1-1/2 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥4500 mL
Pore Size
0.45 µm
Seal Material
Lead O-ring: Silicone-coated EPDM, Outer O-ring: Silicone
Sterility
Gamma
Sterilization
Gamma compatible to 40 kGy. 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Support Material
Polyester/Polyethylene
Trade Name
Opticap®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
MD0HC027H1
Chemistry
Cellulose (CL)Inorganic Filter Aid
Device Configuration
lab scale Pod
Device Material
Glass fiber reinforced polypropylene
Filter Grade
D0HC
Filtration Area
0.027 m²
Gravimetric Extractables
After 24 hour static soak in pure water (Type 1 DI Water) post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 100 L/m2 of media surface area: 39–69 mg/m2
Height
14 cm (5.3 in.)
Length
22 cm (8.5 in.)
Material Size
1
Maximum Differential Pressure, bar (psid)
Forward: 2.1 bar (30 psid) @ 25 °C; 1 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
MD0HC027H1
Chemistry
Cellulose (CL)Inorganic Filter Aid
Device Configuration
lab scale Pod
Device Material
Glass fiber reinforced polypropylene
Filter Grade
D0HC
Filtration Area
0.027 m²
Gravimetric Extractables
After 24 hour static soak in pure water (Type 1 DI Water) post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 100 L/m2 of media surface area: 39–69 mg/m2
Height
14 cm (5.3 in.)
Length
22 cm (8.5 in.)
Material Size
1
Maximum Differential Pressure, bar (psid)
Forward: 2.1 bar (30 psid) @ 25 °C; 1 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C
An aqueous extraction contained less than < 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test
Catalogue Number
MD0HC20CL3
Chemistry
Cellulose (CL)Inorganic Filter Aid
Device Configuration
Micro20
Device Material
Glass-filled Polypropelene
Diameter
2.5 in (6.4 cm)
Filter Grade
D0HC
Filtration Area
20 cm²
Gravimetric Extractables
24 hour static soak in pure water (type 1 DI water) post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 10 L/ft2 (100 L/m2) of media surface area
Height
6.985 cm
Length
28.575 cm
Material Size
3/Pk
Maximum Differential Pressure, bar (psid)
Forward: 30 psid (2.1 bar) at 25 °C ; Reverse: 30 psid (2.1 bar) at 25 °C
Sterilization
Integrity is maintained after 2 autoclave cycles of 60 minutes at 123 °C
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
MD0HC23CL3
Chemistry
Cellulose (CL)Inorganic Filter Aid
Device Configuration
µPod
Device Material
Glass fiber reinforced polypropylene
Filter Grade
D0HC
Filtration Area
0.0023 m²
Gravimetric Extractables
420–750 mg/ft2 per 24-hour static soak in pure water; (type 1 DI water), post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 10 liters per ft2 (100 L/m2) of media surface area
Height
6.6 cm (2.6 in.)
Length
8.9 cm (3.5 in.)
Material Size
3
Maximum Differential Pressure, bar (psid)
Forward: 2.1 bar (30 psid) @ 40 °C. Reverse: 1.0 bar (15 psid) @ 40 °C
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
MD0HC23CL3
Chemistry
Cellulose (CL)Inorganic Filter Aid
Device Configuration
µPod
Device Material
Glass fiber reinforced polypropylene
Filter Grade
D0HC
Filtration Area
0.0023 m²
Gravimetric Extractables
420–750 mg/ft2 per 24-hour static soak in pure water; (type 1 DI water), post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 10 liters per ft2 (100 L/m2) of media surface area
Height
6.6 cm (2.6 in.)
Length
8.9 cm (3.5 in.)
Material Size
3
Maximum Differential Pressure, bar (psid)
Forward: 2.1 bar (30 psid) @ 40 °C. Reverse: 1.0 bar (15 psid) @ 40 °C
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
MD0HC054H1
Chemistry
Cellulose (CL)Inorganic Filter Aid
Device Configuration
lab scale Pod
Device Material
Glass fiber reinforced polypropylene
Filter Grade
D0HC
Filtration Area
0.054 m²
Gravimetric Extractables
After 24 hour static soak in pure water (Type 1 DI Water) post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 100 L/m2 of media surface area: 39–69 mg/m2
Height
14 cm (5.3 in.)
Length
22 cm (8.5 in.)
Material Size
1
Maximum Differential Pressure, bar (psid)
Forward: 2.1 bar (30 psid) @ 25 °C; 1 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C
Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.
Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.