We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
MD0HC054H1
Chemistry
Cellulose (CL)Inorganic Filter Aid
Device Configuration
lab scale Pod
Device Material
Glass fiber reinforced polypropylene
Filter Grade
D0HC
Filtration Area
0.054 m²
Gravimetric Extractables
After 24 hour static soak in pure water (Type 1 DI Water) post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 100 L/m2 of media surface area: 39–69 mg/m2
Height
14 cm (5.3 in.)
Length
22 cm (8.5 in.)
Material Size
1
Maximum Differential Pressure, bar (psid)
Forward: 2.1 bar (30 psid) @ 25 °C; 1 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
MD0HC01FS1
Chemistry
Cellulose (CL)Inorganic Filter Aid
Device Configuration
Pod
Device Material
Glass fiber reinforced polypropylene
Filter Grade
D0HC
Filtration Area
0.11 m²
Gravimetric Extractables
After 24 hour static soak in pure water (Type 1 DI Water) post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 100 L/m2 of media surface area: 39 – 69 mg/m2
Height
32 cm (12.5 in.)
Length
62 cm (24.2 in.)
Material Size
1
Maximum Differential Pressure, bar (psid)
Forward: 2.1 bar (30 psid) @ 25 °C; 1 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
MD0HC01FS1
Chemistry
Cellulose (CL)Inorganic Filter Aid
Device Configuration
Pod
Device Material
Glass fiber reinforced polypropylene
Filter Grade
D0HC
Filtration Area
0.11 m²
Gravimetric Extractables
After 24 hour static soak in pure water (Type 1 DI Water) post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 100 L/m2 of media surface area: 39 – 69 mg/m2
Height
32 cm (12.5 in.)
Length
62 cm (24.2 in.)
Material Size
1
Maximum Differential Pressure, bar (psid)
Forward: 2.1 bar (30 psid) @ 25 °C; 1 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
MD0HC05FS1
Chemistry
Cellulose (CL)Inorganic Filter Aid
Device Configuration
Pod
Device Material
Glass fiber reinforced polypropylene
Filter Grade
D0HC
Filtration Area
0.55 m²
Gravimetric Extractables
After 24 hour static soak in pure water (Type 1 DI Water) post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 100 L/m2 of media surface area: 39 – 69 mg/m2
Height
32 cm (12.5 in.)
Length
62 cm (24.2 in.)
Material Size
1
Maximum Differential Pressure, bar (psid)
Forward: 2.1 bar (30 psid) @ 25 °C; 1 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
MD0HC05FS1
Chemistry
Cellulose (CL)Inorganic Filter Aid
Device Configuration
Pod
Device Material
Glass fiber reinforced polypropylene
Filter Grade
D0HC
Filtration Area
0.55 m²
Gravimetric Extractables
After 24 hour static soak in pure water (Type 1 DI Water) post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 100 L/m2 of media surface area: 39 – 69 mg/m2
Height
32 cm (12.5 in.)
Length
62 cm (24.2 in.)
Material Size
1
Maximum Differential Pressure, bar (psid)
Forward: 2.1 bar (30 psid) @ 25 °C; 1 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C
Integrity is maintained after 1 autoclave cycle of 60 min @ 123 ºC. Filtration performance may be impacted post autoclave. Recommended for post use decontamination only.
Integrity is maintained after 1 autoclave cycle of 60 min @ 123 ºC. Filtration performance may be impacted post autoclave. Recommended for post use decontamination only.
Integrity is maintained after 1 autoclave cycle of 60 min @ 123 ºC. Filtration performance may be impacted post autoclave. Recommended for post use decontamination only.
Integrity is maintained after 1 autoclave cycle of 60 min @ 123 ºC. Filtration performance may be impacted post autoclave. Recommended for post use decontamination only.
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) clot test technique
Catalogue Number
MD0HC10FS1
Chemistry
Cellulose (CL)Inorganic Filter Aid
Device Configuration
Pod
Device Material
Glass fiber reinforced polypropylene
Filter Grade
D0HC
Filtration Area
1.1 m²
Gravimetric Extractables
After 24 hour static soak in pure water (Type 1 DI Water) post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 100 L/m2 of media surface area: 39 – 69 mg/m2
Height
32 cm (12.5 in.)
Length
62 cm (24.2 in.)
Material Size
1
Maximum Differential Pressure, bar (psid)
Forward: 2.1 bar (30 psid) @ 25 °C; 1 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C
Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.