+852-3069 6950
sales@gugent.com.hk
 

GL Sciences GC Columns are designed and manufactured in Japan and offer the lowest bleed levels, the best inertness for acids/bases/mixed functional compounds, and the tightest column-to-column reproducibility.

We supply both capillary columns from very standard till very exclusive versions. Packed columns for gas chromatography are also produced in Japan, we have both Glass and SUS versions with many different packings.


Catalog No. Product Net Price
GLS1010-68144 InertCap Pure-WAX GC Column, 30 m x 0.25 mm, 0.50 µm df 560 
Add to Cart
  • Phase
  • InertCap Pure-WAX
  • Length
  • 30 m
  • Inner diameter
  • 0.25 mm
  • Unit size
  • 1 pc.
  • USP Code
  • G16
  • Material
  • Fused silica
  • Tubing material
  • Fused silica
  • Phase composition
  • Polyethylene Glycol
  • Polarity
  • High polarity
  • Film thickness
  • 0.50 µm
  • Max Temperature
  • iso. 260 ℃ - prog. 260 ℃
  • Application
  • General purpose, Eaters, Perfumes, Alcohols, Aromatic hydrocarbons, FAME (fatty acid methyl ester)
  • Thickness
  • 0.50 µm
GLS1010-68162 InertCap Pure-WAX GC Column, 60 m x 0.25 mm, 0.25 µm df 742 
Add to Cart
  • Phase
  • InertCap Pure-WAX
  • Length
  • 60 m
  • Inner diameter
  • 0.25 mm
  • Unit size
  • 1 pc.
  • USP Code
  • G16
  • Material
  • Fused silica
  • Tubing material
  • Fused silica
  • Phase composition
  • Polyethylene Glycol
  • Polarity
  • High polarity
  • Film thickness
  • 0.25 µm
  • Max Temperature
  • iso. 260 ℃ - prog. 260 ℃
  • Application
  • General purpose, Eaters, Perfumes, Alcohols, Aromatic hydrocarbons, FAME (fatty acid methyl ester)
  • Thickness
  • 0.25 µm
GLS1010-68164 InertCap Pure-WAX GC Column, 60 m x 0.25 mm, 0.50 µm df 742 
Add to Cart
  • Phase
  • InertCap Pure-WAX
  • Length
  • 60 m
  • Inner diameter
  • 0.25 mm
  • Unit size
  • 1 pc.
  • USP Code
  • G16
  • Material
  • Fused silica
  • Tubing material
  • Fused silica
  • Phase composition
  • Polyethylene Glycol
  • Polarity
  • High polarity
  • Film thickness
  • 0.50 µm
  • Max Temperature
  • iso. 260 ℃ - prog. 260 ℃
  • Application
  • General purpose, Eaters, Perfumes, Alcohols, Aromatic hydrocarbons, FAME (fatty acid methyl ester)
  • Thickness
  • 0.50 µm
GLS1010-68242 InertCap Pure-WAX GC Column, 30 m x 0.32 mm, 0.25 µm df 609 
Add to Cart
  • Phase
  • InertCap Pure-WAX
  • Length
  • 30 m
  • Inner diameter
  • 0.32 mm
  • Unit size
  • 1 pc.
  • USP Code
  • G16
  • Material
  • Fused silica
  • Tubing material
  • Fused silica
  • Phase composition
  • Polyethylene Glycol
  • Polarity
  • High polarity
  • Film thickness
  • 0.25 µm
  • Max Temperature
  • iso. 260 ℃ - prog. 260 ℃
  • Application
  • General purpose, Eaters, Perfumes, Alcohols, Aromatic hydrocarbons, FAME (fatty acid methyl ester)
  • Thickness
  • 0.25 µm
GLS1010-68244 InertCap Pure-WAX GC Column, 30 m x 0.32 mm, 0.50 µm df 609 
Add to Cart
  • Phase
  • InertCap Pure-WAX
  • Length
  • 30 m
  • Inner diameter
  • 0.32 mm
  • Unit size
  • 1 pc.
  • USP Code
  • G16
  • Material
  • Fused silica
  • Tubing material
  • Fused silica
  • Phase composition
  • Polyethylene Glycol
  • Polarity
  • High polarity
  • Film thickness
  • 0.50 µm
  • Max Temperature
  • iso. 260 ℃ - prog. 260 ℃
  • Application
  • General purpose, Eaters, Perfumes, Alcohols, Aromatic hydrocarbons, FAME (fatty acid methyl ester)
  • Thickness
  • 0.50 µm
GLS1010-68262 InertCap Pure-WAX GC Column, 60 m x 0.32 mm, 0.25 µm df 756 
Add to Cart
  • Phase
  • InertCap Pure-WAX
  • Length
  • 60 m
  • Inner diameter
  • 0.32 mm
  • Unit size
  • 1 pc.
  • USP Code
  • G16
  • Material
  • Fused silica
  • Tubing material
  • Fused silica
  • Phase composition
  • Polyethylene Glycol
  • Polarity
  • High polarity
  • Film thickness
  • 0.25 µm
  • Max Temperature
  • iso. 260 ℃ - prog. 260 ℃
  • Application
  • General purpose, Eaters, Perfumes, Alcohols, Aromatic hydrocarbons, FAME (fatty acid methyl ester)
  • Thickness
  • 0.25 µm
GLS1010-68264 InertCap Pure-WAX GC Column, 60 m x 0.32 mm, 0.50 µm df 756 
Add to Cart
  • Phase
  • InertCap Pure-WAX
  • Length
  • 60 m
  • Inner diameter
  • 0.32 mm
  • Unit size
  • 1 pc.
  • USP Code
  • G16
  • Material
  • Fused silica
  • Tubing material
  • Fused silica
  • Phase composition
  • Polyethylene Glycol
  • Polarity
  • High polarity
  • Film thickness
  • 0.50 µm
  • Max Temperature
  • iso. 260 ℃ - prog. 260 ℃
  • Application
  • General purpose, Eaters, Perfumes, Alcohols, Aromatic hydrocarbons, FAME (fatty acid methyl ester)
  • Thickness
  • 0.50 µm
GLS1010-68425 InertCap Pure-WAX GC Column, 15 m x 0.53 mm, 1.00 µm df 525 
Add to Cart
  • Phase
  • InertCap Pure-WAX
  • Length
  • 15 m
  • Inner diameter
  • 0.53 mm
  • Unit size
  • 1 pc.
  • USP Code
  • G16
  • Material
  • Fused silica
  • Tubing material
  • Fused silica
  • Phase composition
  • Polyethylene Glycol
  • Polarity
  • High polarity
  • Film thickness
  • 1.00 µm
  • Max Temperature
  • iso. 240 ℃ - prog. 240 ℃
  • Application
  • General purpose, Eaters, Perfumes, Alcohols, Aromatic hydrocarbons, FAME (fatty acid methyl ester)
  • Thickness
  • 1.00 µm
GLS1010-68445 InertCap Pure-WAX GC Column, 30 m x 0.53 mm, 1.00 µm df 644 
Add to Cart
  • Phase
  • InertCap Pure-WAX
  • Length
  • 30 m
  • Inner diameter
  • 0.53 mm
  • Unit size
  • 1 pc.
  • USP Code
  • G16
  • Material
  • Fused silica
  • Tubing material
  • Fused silica
  • Phase composition
  • Polyethylene Glycol
  • Polarity
  • High polarity
  • Film thickness
  • 1.00 µm
  • Max Temperature
  • iso. 240 ℃ - prog. 240 ℃
  • Application
  • General purpose, Eaters, Perfumes, Alcohols, Aromatic hydrocarbons, FAME (fatty acid methyl ester)
  • Thickness
  • 1.00 µm
GLS1010-68465 InertCap Pure-WAX GC Column, 60 m x 0.53 mm, 1.00 µm df 945 
Add to Cart
  • Phase
  • InertCap Pure-WAX
  • Length
  • 60 m
  • Inner diameter
  • 0.53 mm
  • Unit size
  • 1 pc.
  • USP Code
  • G16
  • Material
  • Fused silica
  • Tubing material
  • Fused silica
  • Phase composition
  • Polyethylene Glycol
  • Polarity
  • High polarity
  • Film thickness
  • 1.00 µm
  • Max Temperature
  • iso. 240 ℃ - prog. 240 ℃
  • Application
  • General purpose, Eaters, Perfumes, Alcohols, Aromatic hydrocarbons, FAME (fatty acid methyl ester)
  • Thickness
  • 1.00 µm

Overview

Available capillary columns:


1MS, 1, 1HT, 5MS/Sil, 5MS, 5, Pesticides, 624, 1301, 25, 35, 1701, 17MS, 17, 210, 225, Pure-WAX, WAX, WAX-HT, FFAP and fast GC Columns.


Special Columns: Amines, CHIRAMIX, AQUATIC, AQUATIC-2, Pesticides


Other Columns: Tailor made columns. Columns with build-in Guard Column or Transfer Line and also both.



Resources