Agilent Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is available in single quadrupole and triple quadrupole configurations. Our single quadrupole ICP-MS address the range of typical ICP-MS measurements from routine, regulated analysis to advanced research and demanding applications. Our triple quadrupole ICP-MS will give you the confidence of knowing you can resolve problematic interferences – even in your most difficult samples – delivering results you know you can trust.

Catalog No. Product Net Price
AGIL3710027300 Tubing, peristaltic pump, PVC, purple/black tabs, for pumping reagents with Agilent VGA 76/77 vapor generation accessory, 12/pk. Suitable for all aqueous solutions, medium-concentrated acids and bases. 55 
Add to Cart
  • Inner Diameter (ID)
  • 2.29 mm
  • Length
  • 450 mm
  • UNSPSC Code
  • 40142600
  • Chemical Compatibility
  • Aqueous HF acid
  • Flared
  • No
  • Number of Stops
  • 2
  • Stop Color
  • Purple/Black
  • Tubing Material
  • PVC
AGIL3710027200 Tubing, peristaltic pump, PVC, black/black tabs, for pumping reagents with Agilent VGA 76/77 vapor generation accessory, 12/pk. Suitable for all aqueous solutions, medium-concentrated acids and bases. 55 
Add to Cart
  • Inner Diameter (ID)
  • 0.76 mm
  • Length
  • 450 mm
  • UNSPSC Code
  • 40142600
  • Chemical Compatibility
  • Aqueous HF acid
  • Flared
  • No
  • Notes
  • Required to pump reagents to MSIS
  • Number of Stops
  • 2
  • Stop Color
  • Black/Black
  • Tubing Material
  • PVC
AGIL3710027200 Tubing, peristaltic pump, PVC, black/black tabs, for pumping reagents with Agilent VGA 76/77 vapor generation accessory, 12/pk. Suitable for all aqueous solutions, medium-concentrated acids and bases. 55 
Add to Cart
  • Inner Diameter (ID)
  • 0.76 mm
  • Length
  • 450 mm
  • UNSPSC Code
  • 40142600
  • Chemical Compatibility
  • Aqueous HF acid
  • Flared
  • No
  • Notes
  • Required to pump reagents to MSIS
  • Number of Stops
  • 2
  • Stop Color
  • Black/Black
  • Tubing Material
  • PVC
AGIL8210029100 Sodium tetrahydridoborate(NaBH4), 500 g, hazardous 582 
Add to Cart
  • Volume
  • 500 g
AGIL9910050700 Pump tube beds kit, VGA-76/77 366 
Add to Cart
  • UNSPSC Code
  • 41115700
  • Technique
  • GC
AGIL9910061900 Tubing and connector kit for VGA 77. Includes 1 sample and 2 reagent peristaltic pump tubes, inlet tubing for sample and reagents (3 x 0.4 m), connectors, acid-resistant connecting tubing, gas inlet tubing to gas-liquid separator, reaction coil, and O-rin 270 
Add to Cart
  • UNSPSC Code
  • 40142600
AGIL5043-9310 96-well plate, 0.5 mL, round wells, U shape, polypropylene, 14 mm, 30/pk 110 
Add to Cart
  • UNSPSC Code
  • 41120000
  • Application Compatibility
  • Analytical
  • Brand
  • InfinityLab
  • Material
  • Polypropylene
  • Technique
  • LC LC/MS
AGIL5043-9311 96-well plate, 0.5 mL, round wells, U shape, polypropylene, 14 mm, 120/pk 366 
Add to Cart
  • UNSPSC Code
  • 41120000
  • Application Compatibility
  • Analytical
  • Brand
  • InfinityLab
  • Material
  • Polypropylene
  • Technique
  • LC LC/MS
G8010-60256 Double-pass spray chamber, glass cyclonic design with ball joint socket and UniFit drain outlet, for Agilent 5000 series ICP-OES. For use with aqueous, organic solvents, high matrix or high TDS samples. Includes Helix nebulizer seal and UniFit drain outle 866 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Chemical Compatibility
  • Aqueous Organic solvents
  • Material
  • Borosilicate Glass
  • Type
  • Double pass
G8010-60271 ICP single-pass spray chamber, glass cyclonic design with ball joint socket and UniFit drain outlet, for Agilent 5000 series ICP-OES. For use with aqueous and low matrix samples where best sensitivity and lowest LODs are required. Includes Helix nebulizer 645 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Chemical Compatibility
  • Aqueous
  • Material
  • Borosilicate Glass
  • Type
  • Single pass

Overview

ICP-MS system operates with an ICP-MS Nebulizer, in which a high velocity Argon gas stream meets a liquid stream causing filmwise breakup of the solution into a fine aerosol. The aerosol particle size should ideally be sub-10µm with a narrow particle size distribution to achieve efficient atomization and ionization. Agilent offers a comprehensive range of ICP-MS nebulizers and supplies to solve any ICP-MS analysis challenge.

The portfolio includes standard glass concentric nebulizer (MicroMist), quartz and inert PFA nebulizers (MicroFlow and C-Flow), as well as robust Mira Mist PEEK or PTFE for high TDS samples and low-flow self-aspirating or total consumption nebulizers for your clinical or limited volume samples. ICP-MS nebulizer support is provided with a full range of accessories for all models including nebulizer cleaning tools.


The ICP torch is used to form, shape, and sustain an argon plasma which atomizes and ionizes the sample aerosol. Agilent ICP-MS Torches with Shield Torch System (STS) provide precise ion energy control, ensuring high sensitivity and stability, even in cool plasma mode for effective interference removal (ArO+).

Our portfolio is comprised of a wide range of ICP torches for your specific ICP-MS configuration. One-piece quartz torches offer the best stability and ease of use. The large 2.5mm injector on the standard torch gives maximum robustness and lowest matrix interferences for the best plasma stability. Single-piece torches with narrow bore injectors (1.0mm or 1.5 mm) are designed for use with organic solvents, to reduce plasma loading and improve plasma stability. Optional semi-demountable quartz torches with removable platinum or sapphire injectors are also available for use with the PFA inert sample introduction kit.


Resources