+852-3069 6950
sales@gugent.com.hk
 

Chromatography resins

Chromatography resins in bottles to capture and polish mAbs, antibody fragments, other biomolecules, and vaccines.


Catalog No. Product Net Price
CYT29256254 ReadyToProcess Capto Butyl ImpRes 32 L (450/200) Special offer 
Add to Cart
  • Chromatography technique
  • Hydrophobic interaction chromatography
  • Bed volume
  • 10 L
  • Pressure max. (over the packed bed during operation)
  • 0.3 MPa (3 bar, 44 psi)
  • Pack size
  • 10 L
  • Bed height
  • 200 mm
  • Column i.d.
  • 251
  • Application
  • For manufacturing of biopharmaceuticals for clinical phase I and II studies. Depending on the scale of operations, the columns can also be used for full-scale manufacturing, as well as for preclinical studies.
  • Storage
  • 4°C to 30°C, 20% ethanol
  • Bed dimensions
  • 251 × 200 mm
  • Certificate of Analysis
  • Yes
CYT29474655 ReadyToProcess Capto Butyl ImpRes 57 L (600/200) Special offer 
Add to Cart
  • Chromatography technique
  • Hydrophobic interaction chromatography
  • Bed volume
  • 10 L
  • Pressure max. (over the packed bed during operation)
  • 0.3 MPa (3 bar, 44 psi)
  • Pack size
  • 10 L
  • Bed height
  • 200 mm
  • Column i.d.
  • 251
  • Application
  • For manufacturing of biopharmaceuticals for clinical phase I and II studies. Depending on the scale of operations, the columns can also be used for full-scale manufacturing, as well as for preclinical studies.
  • Storage
  • 4°C to 30°C, 20% ethanol
  • Bed dimensions
  • 251 × 200 mm
  • Certificate of Analysis
  • Yes
CYT29647159 ReadyToProcess Capto Butyl ImpRes 5 L (178/200) Special offer 
Add to Cart
  • Chromatography technique
  • Hydrophobic interaction chromatography
  • Bed volume
  • 10 L
  • Pressure max. (over the packed bed during operation)
  • 0.3 MPa (3 bar, 44 psi)
  • Pack size
  • 10 L
  • Bed height
  • 200 mm
  • Column i.d.
  • 251
  • Application
  • For manufacturing of biopharmaceuticals for clinical phase I and II studies. Depending on the scale of operations, the columns can also be used for full-scale manufacturing, as well as for preclinical studies.
  • Storage
  • 4°C to 30°C, 20% ethanol
  • Bed dimensions
  • 251 × 200 mm
  • Certificate of Analysis
  • Yes
CYT17371640 PreDictor RoboColum Capto MMC ImpRes, 200 332 
Add to Cart
  • Bed volume
  • 200 µL
  • For use with
  • Robotic liquid handling station
CYT17371641 PreDictor RoboColumn Capto MMC ImpRes, 600 332 
Add to Cart
  • Bed volume
  • 200 µL
  • For use with
  • Robotic liquid handling station
CYT28986087 PreDictor RoboColumn SP Sepharose FF, 200 μL 332 
Add to Cart
  • Bed volume
  • 200 µL
  • For use with
  • Robotic liquid handling station
CYT28986181 PreDictor RoboColumn SP Sepharose FF, 600 μL 332 
Add to Cart
  • Bed volume
  • 200 µL
  • For use with
  • Robotic liquid handling station
CYT17371501 Capto adhere ImpRes, 25 mL 238 
Add to Cart
  • Pack size
  • 25 mL
  • Chemical stability
  • Commonly used aqueous buffers, 1 M acetic acid, 1 M NaOH, 2 M NaCl, 5% 1-propanol, 30% isopropanol, 70% ethanol
  • Storage
  • 4°C to 30°C in 20% ethanol
  • Certificate of Analysis
  • Yes
  • BioProcess resin
  • Yes
  • Ionic Capacity
  • 0.08-0.11 mmol Cl-/ml medium
  • Ligand
  • Multimodal strong anion exchanger
  • Matrix
  • High-flow agarose
  • Pressure/Flow Specification
  • 300 kPa
  • pH stability, CIP
  • 2–14
  • pH stability, operational
  • 3–12
  • Avoid Using
  • Oxidizing agents, anionic detergents
  • Binding Capacity/ml Chromatography Medium
  • 45-85 mg Mab/mL
CYT17371502 Capto adhere ImpRes, 100 mL 786 
Add to Cart
  • Pack size
  • 25 mL
  • Chemical stability
  • Commonly used aqueous buffers, 1 M acetic acid, 1 M NaOH, 2 M NaCl, 5% 1-propanol, 30% isopropanol, 70% ethanol
  • Storage
  • 4°C to 30°C in 20% ethanol
  • Certificate of Analysis
  • Yes
  • BioProcess resin
  • Yes
  • Ionic Capacity
  • 0.08-0.11 mmol Cl-/ml medium
  • Ligand
  • Multimodal strong anion exchanger
  • Matrix
  • High-flow agarose
  • Pressure/Flow Specification
  • 300 kPa
  • pH stability, CIP
  • 2–14
  • pH stability, operational
  • 3–12
  • Avoid Using
  • Oxidizing agents, anionic detergents
  • Binding Capacity/ml Chromatography Medium
  • 45-85 mg Mab/mL
CYT17371503 Capto adhere ImpRes, 1 L 5770 
Add to Cart
  • Pack size
  • 25 mL
  • Chemical stability
  • Commonly used aqueous buffers, 1 M acetic acid, 1 M NaOH, 2 M NaCl, 5% 1-propanol, 30% isopropanol, 70% ethanol
  • Storage
  • 4°C to 30°C in 20% ethanol
  • Certificate of Analysis
  • Yes
  • BioProcess resin
  • Yes
  • Ionic Capacity
  • 0.08-0.11 mmol Cl-/ml medium
  • Ligand
  • Multimodal strong anion exchanger
  • Matrix
  • High-flow agarose
  • Pressure/Flow Specification
  • 300 kPa
  • pH stability, CIP
  • 2–14
  • pH stability, operational
  • 3–12
  • Avoid Using
  • Oxidizing agents, anionic detergents
  • Binding Capacity/ml Chromatography Medium
  • 45-85 mg Mab/mL

Overview

Affinity antibody

Antibody affinity purification using protein A resins is an effective chromatography technique for purifying recombinant monoclonal antibodies for research and bioprocessing


Affinity resins – specific groups

Affinity resins for purifying specific groups of biomolecules


Affinity resins - tagged proteins

Purify fusion proteins with his-tag, GST, and MBP affinity resins


Desalting and buffer exchange resins


Hydrophobic interaction resins

Resins for hydrophobic interaction chromatography (HIC)


Immunoprecipitation resins

Resins for protein immunoprecipitation using protein A or protein G


Ion exchange resins

Chromatography resins for anion exchange and cation exchange chromatography


Multimodal resins

Resins for mixed mode or multimodal chromatography


Reversed phase resins


Size exclusion resins

Size exclusion resins for separation and desalting



Resources