+852-3069 6950
sales@gugent.com.hk
 

Stainless steel HPLC columns for analytical or preparative applictions from MACHEREY‑NAGEL are a great choice for your daily labwork.

* NUCLEOSIL HPLC phases have gained wide acceptance as routine chromatographic packings for very different fields of modern chromatography. It is one of the first spherical silicas used in HPLC and is an absolutely reliable choice for routine analyses.

* NUCLEODUR as a state-of-the-art silica is the ideal base material for modern HPLC phases. It is the result of MACHEREY-NAGEL's pioneering research in chromatography for almost 50 years. NUCLEODUR HPLC columns with 1.8 µm particle size for increased separation efficiency are used for UHPLC applications.

* Due to core-shell technology NUCLEOSHELL columns provide highly efficient separation results with a comparably lower back pressure to fully porous materials.

Catalog No. Product Net Price
MN762077.100 VP HPLC column (preparative), NUCLEODUR 100-5, 5 µm, 50x10 mm Special offer 
Add to Cart
  • Recommended application(s)
  • For examples please see analytical NUCLEODUR normal phases, NP applications (preparative)
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x preparative HPLC column, instruction leaflet, certificate of analysis
  • Hazardous material
  • No
  • Method
  • HPLC, preparative
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR 100-5
  • USP listing
  • L3
  • Surface chemistry
  • Unmodified high purity silica gel (SiOH)
  • Mode
  • Normal phase (NP)
  • Type
  • VP HPLC column (preparative)
  • Hardware
  • Stainless steel
  • Column length
  • 50 mm
  • Column inner diameter
  • 10 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 5 µm
  • Eluent in HPLC column
  • n-heptane
  • Endcapped
  • No
  • Carbon content
  • Not available or not applicable
  • pH stability
  • 2.0–8.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
  • Column volume
  • 3.9 mL
MN762077.210 VP HPLC column (preparative), NUCLEODUR 100-5, 5 µm, 50x21 mm Special offer 
Add to Cart
  • Recommended application(s)
  • For examples please see analytical NUCLEODUR normal phases, NP applications (preparative)
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x preparative HPLC column, instruction leaflet, certificate of analysis
  • Hazardous material
  • No
  • Method
  • HPLC, preparative
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR 100-5
  • USP listing
  • L3
  • Surface chemistry
  • Unmodified high purity silica gel (SiOH)
  • Mode
  • Normal phase (NP)
  • Type
  • VP HPLC column (preparative)
  • Hardware
  • Stainless steel
  • Column length
  • 50 mm
  • Column inner diameter
  • 21 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 5 µm
  • Eluent in HPLC column
  • n-heptane
  • Endcapped
  • No
  • Carbon content
  • Not available or not applicable
  • pH stability
  • 2.0–8.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
  • Column volume
  • 17 mL
MN762078.100 VP HPLC column (preparative), NUCLEODUR 100-5, 5 µm, 125x10 mm Special offer 
Add to Cart
  • Recommended application(s)
  • For examples please see analytical NUCLEODUR normal phases, NP applications (preparative)
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x preparative HPLC column, instruction leaflet, certificate of analysis
  • Hazardous material
  • No
  • Method
  • HPLC, preparative
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR 100-5
  • USP listing
  • L3
  • Surface chemistry
  • Unmodified high purity silica gel (SiOH)
  • Mode
  • Normal phase (NP)
  • Type
  • VP HPLC column (preparative)
  • Hardware
  • Stainless steel
  • Column length
  • 125 mm
  • Column inner diameter
  • 10 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 5 µm
  • Eluent in HPLC column
  • n-heptane
  • Endcapped
  • No
  • Carbon content
  • Not available or not applicable
  • pH stability
  • 2.0–8.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
  • Column volume
  • 9.8 mL
MN762078.210 VP HPLC column (preparative), NUCLEODUR 100-5, 5 µm, 125x21 mm Special offer 
Add to Cart
  • Recommended application(s)
  • For examples please see analytical NUCLEODUR normal phases, NP applications (preparative)
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x preparative HPLC column, instruction leaflet, certificate of analysis
  • Hazardous material
  • No
  • Method
  • HPLC, preparative
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR 100-5
  • USP listing
  • L3
  • Surface chemistry
  • Unmodified high purity silica gel (SiOH)
  • Mode
  • Normal phase (NP)
  • Type
  • VP HPLC column (preparative)
  • Hardware
  • Stainless steel
  • Column length
  • 125 mm
  • Column inner diameter
  • 21 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 5 µm
  • Eluent in HPLC column
  • n-heptane
  • Endcapped
  • No
  • Carbon content
  • Not available or not applicable
  • pH stability
  • 2.0–8.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
  • Column volume
  • 43 mL
MN718256 VarioPrep guard column holder for VP 10/16 guard columns Special offer 
Add to Cart
  • Guard column dimension
  • 10 mm length, 16 mm ID
  • Accessory for HPLC hardware
  • VP
  • Recommended application(s)
  • HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x Guard column holder VP
  • Hazardous material
  • No
  • Hardware
  • VP
MN718253 VarioPrep guard column holder for VP 15/32 guard columns Special offer 
Add to Cart
  • Guard column dimension
  • 15 mm length, 32 mm ID
  • Accessory for HPLC hardware
  • VP
  • Recommended application(s)
  • HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x Guard column holder VP
  • Hazardous material
  • No
  • Hardware
  • VP
MN718255 VarioPrep guard column holder for VP 15/50 guard columns Special offer 
Add to Cart
  • Guard column dimension
  • 15 mm length, 50 mm ID
  • Accessory for HPLC hardware
  • VP
  • Recommended application(s)
  • HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x Guard column holder VP
  • Hazardous material
  • No
  • Hardware
  • VP
MN718251 VarioPrep guard column holder for VP 10/8 guard columns Special offer 
Add to Cart
  • Guard column dimension
  • 10 mm length, 8 mm ID
  • Accessory for HPLC hardware
  • VP
  • Recommended application(s)
  • HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x Guard column holder VP
  • Hazardous material
  • No
  • Hardware
  • VP
MN760193.20 EC HPLC column (analytical), NUCLEODUR 300-5 C4 ec, 5 µm, 100x2 mm Special offer 
Add to Cart
  • Recommended application(s)
  • Biological macromolecules, HPLC, Peptides, Proteins
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x analytical HPLC column, instruction leaflet, certificate of analysis
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR 300-5 C4 ec
  • USP listing
  • L26
  • Surface chemistry
  • Medium density monomeric butyl (C4) wide-pore modification
  • Mode
  • Reversed phase (RP)
  • Type
  • EC HPLC column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 100 mm
  • Column inner diameter
  • 2 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 5 µm
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 2.5 %
  • pH stability
  • 1.0–9.0
  • Pore size
  • 300 Å
  • Specific surface according to BET
  • 100 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 450 bar
  • Column volume
  • 0.3 mL
MN760193.30 EC HPLC column (analytical), NUCLEODUR 300-5 C4 ec, 5 µm, 100x3 mm Special offer 
Add to Cart
  • Recommended application(s)
  • Biological macromolecules, HPLC, Peptides, Proteins
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x analytical HPLC column, instruction leaflet, certificate of analysis
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR 300-5 C4 ec
  • USP listing
  • L26
  • Surface chemistry
  • Medium density monomeric butyl (C4) wide-pore modification
  • Mode
  • Reversed phase (RP)
  • Type
  • EC HPLC column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 100 mm
  • Column inner diameter
  • 3 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 5 µm
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 2.5 %
  • pH stability
  • 1.0–9.0
  • Pore size
  • 300 Å
  • Specific surface according to BET
  • 100 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 450 bar
  • Column volume
  • 0.7 mL

Overview

High performance liquid chromatography (HPLC) is part of liquid chromatographic separating processes of substance mixtures and their analysis. At the beginning the technique was also called high pressure liquid chromatography due to the high back pressure of the column. HPLC offers qualitative (identification of substances) and quantitative (concentration determination) analysis by comparison with standard substances. The term HPLC was introduced in the 1970s, for the delineation of the high-performance method to the in the 1930s developed column liquid chromatography (column chromatography). At the beginning of the 21st century the HPLC was complemented by the even more efficient UHPLC (ultra high performance liquid chromatography). Hereby even higher pressures (> 400 bar) result in shorter analysis time and enhanced efficiency enabling a higher sample throughput with smaller sample volumes.


Detailed information of the particular properties of the high-purity silica phases NUCLEODUR, the established standard silica NUCLEOSIL and the modern Core-Shell material NUCLEOSHELL as well as phases for special separations can be found at the equivalent HPLC- and UHPLC-columns.


Each MACHEREY‑NAGEL HPLC / UHPLC column is individually tested according to the most important characteristic parameters in quality control and the results are documented in a certificate of analysis.



Resources