By using CHROMAFIL filtration products (syringe filters, filtration cartridges, 96-well plates) unwanted particles are removed which can otherwise cause contamination and clogging of sensitive instrumentation. So, filtering your samples leads to an increase of lifetime and less downtime of chromatographic columns and equipment as well as gives more consistent and reproducible results. Inside the filter products are membranes with hydrophilic or hydrophobic properties. For example the hydrophilic multipurpose PET membrane is suitable for polar as well as nonpolar solvents.


MACHEREY‑NAGEL offers a wide selection of membranes in syringe filters. CHROMAFIL Xtra are syringe filters that are labeled for method validation and certification.

Filtration cartridges are supplied with regenerated cellulose, glass fiber, polytetrafluoroethylene, polyester (polyethylene terephthalate) as well as with polyvinylidene difluoride membrane in different pore sizes and cartridge volumes.

CHROMAFIL 96‑well polypropylene plates with different membrane types for simultaneous filtration of 96 samples are also available.


Catalog No. Product Net Price
MN729026 Syringe filters, color coded, CHROMAFIL CA, 25 mm, 0.2 µm Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Filtration
  • Brand
  • CHROMAFIL
  • Hardware
  • Polypropylene (PP) housing with filter membrane
  • Selling unit
  • 100 pieces, 400 pieces
  • Recommended application(s)
  • Filtration of water-soluble oligomers and polymers, especially suited for biological macromolecules, Suitable for UHPLC, core-shell and HPLC columns packed with particles > 3 µm, GC, SFC
  • Storage temperature
  • RT
MN729027 Syringe filters, color coded, CHROMAFIL CA, 25 mm, 0.45 µm Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Filtration
  • Brand
  • CHROMAFIL
  • Hardware
  • Polypropylene (PP) housing with filter membrane
  • Selling unit
  • 100 pieces, 400 pieces
  • Recommended application(s)
  • Filtration of water-soluble oligomers and polymers, especially suited for biological macromolecules, Suitable for HPLC columns packed with particles > 3 µm, GC, SFC
  • Storage temperature
  • RT
MN729226 Syringe filters, labeled, CHROMAFIL Xtra CA, 25 mm, 0.2 µm Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Filtration
  • Brand
  • CHROMAFIL Xtra
  • Hardware
  • Polypropylene (PP) housing with filter membrane
  • Selling unit
  • 100 pieces, 400 pieces
  • Recommended application(s)
  • Filtration of water-soluble oligomers and polymers, especially suited for biological macromolecules, Suitable for UHPLC, core-shell and HPLC columns packed with particles > 3 µm, GC, SFC
  • Storage temperature
  • RT
MN729227 Syringe filters, labeled, CHROMAFIL Xtra CA, 25 mm, 0.45 µm Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Filtration
  • Brand
  • CHROMAFIL Xtra
  • Hardware
  • Polypropylene (PP) housing with filter membrane
  • Selling unit
  • 100 pieces, 400 pieces
  • Recommended application(s)
  • Filtration of water-soluble oligomers and polymers, especially suited for biological macromolecules, Suitable for HPLC columns packed with particles > 3 µm, GC, SFC
  • Storage temperature
  • RT
MN729254 Syringe filters, labeled, CHROMAFIL Xtra CA, 13 mm, 0.2 µm Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Filtration
  • Brand
  • CHROMAFIL Xtra
  • Hardware
  • Polypropylene (PP) housing with filter membrane
  • Recommended application(s)
  • Filtration of water-soluble oligomers and polymers, especially suited for biological macromolecules, Suitable for UHPLC, core-shell and HPLC columns packed with particles > 3 µm, GC, SFC
  • Storage temperature
  • RT
MN729255 Syringe filters, labeled, CHROMAFIL Xtra CA, 13 mm, 0.45 µm Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Filtration
  • Brand
  • CHROMAFIL Xtra
  • Hardware
  • Polypropylene (PP) housing with filter membrane
  • Recommended application(s)
  • Filtration of water-soluble oligomers and polymers, especially suited for biological macromolecules, Suitable for HPLC columns packed with particles > 3 µm, GC, SFC
  • Storage temperature
  • RT
MN729010 Syringe filters, color coded, CHROMAFIL PA, 3 mm, 0.2 µm Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Filtration
  • Brand
  • CHROMAFIL
  • Hardware
  • Polypropylene (PP) housing with filter membrane
  • Recommended application(s)
  • For filtration of medium polar organic-aqueous liquids, Suitable for UHPLC, core-shell and HPLC columns packed with particles > 3 µm, GC, SFC
  • Storage temperature
  • RT
MN729011 Syringe filters, color coded, CHROMAFIL PA, 3 mm, 0.45 µm Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Filtration
  • Brand
  • CHROMAFIL
  • Hardware
  • Polypropylene (PP) housing with filter membrane
  • Recommended application(s)
  • For filtration of medium polar organic-aqueous liquids, Suitable for HPLC columns packed with particles > 3 µm, GC, SFC
  • Storage temperature
  • RT
MN729012 Syringe filters, color coded, CHROMAFIL PA, 25 mm, 0.2 µm Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Filtration
  • Brand
  • CHROMAFIL
  • Hardware
  • Polypropylene (PP) housing with filter membrane
  • Selling unit
  • 100 pieces, 400 pieces
  • Recommended application(s)
  • For filtration of medium polar organic-aqueous liquids, Suitable for UHPLC, core-shell and HPLC columns packed with particles > 3 µm, GC, SFC
  • Storage temperature
  • RT
MN729013 Syringe filters, color coded, CHROMAFIL PA, 25 mm, 0.45 µm Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Filtration
  • Brand
  • CHROMAFIL
  • Hardware
  • Polypropylene (PP) housing with filter membrane
  • Selling unit
  • 100 pieces, 400 pieces
  • Recommended application(s)
  • For filtration of medium polar organic-aqueous liquids, Suitable for HPLC columns packed with particles > 3 µm, GC, SFC
  • Storage temperature
  • RT

Overview

Chemical compatibility of CHROMAFIL membrane and housing material

The chemical compatibility depends on several parameters such as time, pressure, temperature and concentration. In most cases, CHROMAFIL products will have only short contact with a solvent. In these cases they may be used despite of limited compatibility. For example, a PTFE filter with PP housing does not liberate any UV-detectable substances during filtration of 5 mL THF, although PP shows only limited resistance towards THF.


Materials used in CHROMAFIL products


MV = Cellulose mixed ester

CA = Cellulose acetate

RC = Regenerated cellulose

PA = Polyamide

PTFE = Polytetrafluoroethylene

H-PTFE = hydrophilized polytetrafluoroethylene

PVDF = Polyvinylidenedifluoride

PES = Polyethersulfone

PET = Polyester

GF = Glass fiber

IC = Special membrane for Ion chromatography

PP = Polypropylene (housing material)



Resources