+852-3069 6950
sales@gugent.com.hk
 

Liquid preparation and management

Easy to connect single-use components for robust mixing, easy handling, and convenient storage of bioprocess liquids.


Catalog No. Product Net Price
CYT17097816 PreDictor Butyl S Sepharose 6 Fast Flow, 6 992 
Add to Cart
  • Chromatography technique
  • Hydrophobic Interaction Chromatography
  • Dimensions
  • 127.8 x 85.5 x 30.6 mm
  • Material
  • Polypropylene (PP) and Polyethylene (PE)
  • Storage
  • 4 to 30°C, 20% Ethanol
  • Resin suspensions in total volumes
  • 200 μl for 2 μl sedimented resin/well\n500 μl for 6, 20, and 50 μl sedimented resin/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented resin/well\n– 200 μl for 20 μl sedimented resin/well\n– 500 μl for 8 μl sedimented resin/well\n– 375 μl for 6 μl sedimented resin/well\n– 250 μl for 4 μl sedimented resin/well\n– 125 μl for 2 μl sedimented resin/well
  • Centrifugation force recommended
  • 100 x g (Sample Dependent)-500 x g (Sample Dependent)
  • Operating temp. max.
  • 30°C
  • Operating temp. min.
  • 4°C
  • Well Volume
  • 800
CYT17097817 PreDictor Butyl S Sepharose 6 Fast Flow, 50 992 
Add to Cart
  • Chromatography technique
  • Hydrophobic Interaction Chromatography
  • Dimensions
  • 127.8 x 85.5 x 30.6 mm
  • Material
  • Polypropylene (PP) and Polyethylene (PE)
  • Storage
  • 4 to 30°C, 20% Ethanol
  • Resin suspensions in total volumes
  • 200 μl for 2 μl sedimented resin/well\n500 μl for 6, 20, and 50 μl sedimented resin/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented resin/well\n– 200 μl for 20 μl sedimented resin/well\n– 500 μl for 8 μl sedimented resin/well\n– 375 μl for 6 μl sedimented resin/well\n– 250 μl for 4 μl sedimented resin/well\n– 125 μl for 2 μl sedimented resin/well
  • Centrifugation force recommended
  • 100 x g (Sample Dependent)-500 x g (Sample Dependent)
  • Operating temp. max.
  • 30°C
  • Operating temp. min.
  • 4°C
  • Well Volume
  • 800
CYT14100503 Microplate 96-well 144 
Add to Cart
  • For use with
  • Biacore™ 8K+, Biacore™ 8K, Biacore™ 4000, Biacore™ S200, Biacore™ T200, Biacore™ T100, Biacore™ 3000, and Biacore™ C SPR systems
  • Material
  • Polystyrene (PS)
CYT28925820 PreDictor MabSelect, 6 992 
Add to Cart
  • Format
  • Prepacked 96-well plate
  • Chromatography technique
  • Antibody affinity chromatography
  • Dimensions
  • 127.8 x 85.5 x 30.6 mm
  • Material
  • Polypropylene (PP) and Polyethylene (PE)
  • Application
  • Centrifugation
  • Storage
  • 4 to 8°C, 20% Ethanol
  • Ligand
  • Recombinant protein
  • Chromatography resin
  • MabSelect
  • Resin suspensions in total volumes
  • 200 μl for 2 μl sedimented resin/well\n500 μl for 6, 20, and 50 μl sedimented resin/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented resin/well\n– 200 μl for 20 μl sedimented resin/well\n– 500 μl for 8 μl sedimented resin/well\n– 375 μl for 6 μl sedimented resin/well\n– 250 μl for 4 μl sedimented resin/well\n– 125 μl for 2 μl sedimented resin/well
  • Centrifugation force recommended
  • 100 x g (Sample Dependent)-500 x g (Sample Dependent)
  • Operating temp. max.
  • 30°C
  • Operating temp. min.
  • 4°C
  • Scale
  • Process development
  • Resin Type
  • MabSelect
  • Well Volume
  • 800
CYT28925821 PreDictor MabSelect, 20 992 
Add to Cart
  • Format
  • Prepacked 96-well plate
  • Chromatography technique
  • Antibody affinity chromatography
  • Dimensions
  • 127.8 x 85.5 x 30.6 mm
  • Material
  • Polypropylene (PP) and Polyethylene (PE)
  • Application
  • Centrifugation
  • Storage
  • 4 to 8°C, 20% Ethanol
  • Ligand
  • Recombinant protein
  • Chromatography resin
  • MabSelect
  • Resin suspensions in total volumes
  • 200 μl for 2 μl sedimented resin/well\n500 μl for 6, 20, and 50 μl sedimented resin/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented resin/well\n– 200 μl for 20 μl sedimented resin/well\n– 500 μl for 8 μl sedimented resin/well\n– 375 μl for 6 μl sedimented resin/well\n– 250 μl for 4 μl sedimented resin/well\n– 125 μl for 2 μl sedimented resin/well
  • Centrifugation force recommended
  • 100 x g (Sample Dependent)-500 x g (Sample Dependent)
  • Operating temp. max.
  • 30°C
  • Operating temp. min.
  • 4°C
  • Scale
  • Process development
  • Resin Type
  • MabSelect
  • Well Volume
  • 800
CYT28925822 PreDictor MabSelect, 50 992 
Add to Cart
  • Format
  • Prepacked 96-well plate
  • Chromatography technique
  • Antibody affinity chromatography
  • Dimensions
  • 127.8 x 85.5 x 30.6 mm
  • Material
  • Polypropylene (PP) and Polyethylene (PE)
  • Application
  • Centrifugation
  • Storage
  • 4 to 8°C, 20% Ethanol
  • Ligand
  • Recombinant protein
  • Chromatography resin
  • MabSelect
  • Resin suspensions in total volumes
  • 200 μl for 2 μl sedimented resin/well\n500 μl for 6, 20, and 50 μl sedimented resin/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented resin/well\n– 200 μl for 20 μl sedimented resin/well\n– 500 μl for 8 μl sedimented resin/well\n– 375 μl for 6 μl sedimented resin/well\n– 250 μl for 4 μl sedimented resin/well\n– 125 μl for 2 μl sedimented resin/well
  • Centrifugation force recommended
  • 100 x g (Sample Dependent)-500 x g (Sample Dependent)
  • Operating temp. max.
  • 30°C
  • Operating temp. min.
  • 4°C
  • Scale
  • Process development
  • Resin Type
  • MabSelect
  • Well Volume
  • 800
CYT28943283 PreDictor MabSelect Isotherm 1285 
Add to Cart
  • Format
  • Prepacked 96-well plate
  • Chromatography technique
  • Antibody affinity chromatography
  • Dimensions
  • 127.8 x 85.5 x 30.6 mm
  • Material
  • Polypropylene (PP) and Polyethylene (PE)
  • Application
  • Centrifugation
  • Storage
  • 4 to 8°C, 20% Ethanol
  • Ligand
  • Recombinant protein
  • Chromatography resin
  • MabSelect
  • Resin suspensions in total volumes
  • 200 μl for 2 μl sedimented resin/well\n500 μl for 6, 20, and 50 μl sedimented resin/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented resin/well\n– 200 μl for 20 μl sedimented resin/well\n– 500 μl for 8 μl sedimented resin/well\n– 375 μl for 6 μl sedimented resin/well\n– 250 μl for 4 μl sedimented resin/well\n– 125 μl for 2 μl sedimented resin/well
  • Centrifugation force recommended
  • 100 x g (Sample Dependent)-500 x g (Sample Dependent)
  • Operating temp. max.
  • 30°C
  • Operating temp. min.
  • 4°C
  • Scale
  • Process development
  • Resin Type
  • MabSelect
  • Well Volume
  • 800
CYT28985262 PreDictor MabSelect, 150ul (4x96) 1314 
Add to Cart
  • Format
  • Prepacked 96-well plate
  • Chromatography technique
  • Antibody affinity chromatography
  • Dimensions
  • 127.8 x 85.5 x 30.6 mm
  • Material
  • Polypropylene (PP) and Polyethylene (PE)
  • Application
  • Centrifugation
  • Storage
  • 4 to 8°C, 20% Ethanol
  • Ligand
  • Recombinant protein
  • Chromatography resin
  • MabSelect
  • Resin suspensions in total volumes
  • 200 μl for 2 μl sedimented resin/well\n500 μl for 6, 20, and 50 μl sedimented resin/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented resin/well\n– 200 μl for 20 μl sedimented resin/well\n– 500 μl for 8 μl sedimented resin/well\n– 375 μl for 6 μl sedimented resin/well\n– 250 μl for 4 μl sedimented resin/well\n– 125 μl for 2 μl sedimented resin/well
  • Centrifugation force recommended
  • 100 x g (Sample Dependent)-500 x g (Sample Dependent)
  • Operating temp. max.
  • 30°C
  • Operating temp. min.
  • 4°C
  • Scale
  • Process development
  • Resin Type
  • MabSelect
  • Well Volume
  • 800
CYT28992322 PreDictor Butyl Sepharose 4 Fast Flow, 6 1012 
Add to Cart
  • Chromatography technique
  • Hydrophobic Interaction Chromatography
  • Dimensions
  • 127.8 x 85.5 x 30.6 mm
  • Material
  • Polypropylene (PP) and Polyethylene (PE)
  • Storage
  • 4 to 30°C, 20% Ethanol
  • Resin suspensions in total volumes
  • 200 μl for 2 μl sedimented resin/well\n500 μl for 6, 20, and 50 μl sedimented resin/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented resin/well\n– 200 μl for 20 μl sedimented resin/well\n– 500 μl for 8 μl sedimented resin/well\n– 375 μl for 6 μl sedimented resin/well\n– 250 μl for 4 μl sedimented resin/well\n– 125 μl for 2 μl sedimented resin/well
  • Centrifugation force recommended
  • 100 x g (Sample Dependent)-500 x g (Sample Dependent)
  • Operating temp. max.
  • 30°C
  • Operating temp. min.
  • 4°C
  • Well Volume
  • 800
CYT28992378 PreDictor Butyl Sepharose 4 Fast Flow, 50 1012 
Add to Cart
  • Chromatography technique
  • Hydrophobic Interaction Chromatography
  • Dimensions
  • 127.8 x 85.5 x 30.6 mm
  • Material
  • Polypropylene (PP) and Polyethylene (PE)
  • Storage
  • 4 to 30°C, 20% Ethanol
  • Resin suspensions in total volumes
  • 200 μl for 2 μl sedimented resin/well\n500 μl for 6, 20, and 50 μl sedimented resin/well\nFor PreDictor isotherm plates:\n– 500 μl for 50 μl sedimented resin/well\n– 200 μl for 20 μl sedimented resin/well\n– 500 μl for 8 μl sedimented resin/well\n– 375 μl for 6 μl sedimented resin/well\n– 250 μl for 4 μl sedimented resin/well\n– 125 μl for 2 μl sedimented resin/well
  • Centrifugation force recommended
  • 100 x g (Sample Dependent)-500 x g (Sample Dependent)
  • Operating temp. max.
  • 30°C
  • Operating temp. min.
  • 4°C
  • Well Volume
  • 800