+852-3069 6950
sales@gugent.com.hk
 

Process Analytics


Process Instrumentation for measuring pH, Dissolved Oxygen, Conductivity, Turbidity, TOC, Sodium, Silica, Gas Analyzer


Catalog No. Product Net Price
METL58031243 Cond Sensor 2Tri 4E SS PEEK VP Special offer 
Add to Cart
  • Connection
  • VP (IP 68) , 2 inch Tri-Clamp
  • Hazardous Area Approvals
  • No
  • Hygienic/Biocompatibility Approvals
  • Yes
  • Measured Pressure Resistance
  • 70 psig @ 302 °F and 200 psig @ 122 °F (5 bar @ 150 °C and 14 bar @ 50 °C)
  • Measurement range
  • 10 - 650,000 µS/cm
  • Model Family
  • Analog
  • Primary Media/Application
  • Other Water Processes Pharmaceutical Waters Other Industrial Processes Wastewater Pharmaceutical/Life Science Production
  • Temperature Sensor
  • PT 1000
METL58031243 Cond Sensor 2Tri 4E SS PEEK VP Special offer 
Add to Cart
  • Connection
  • VP (IP 68) , 2 inch Tri-Clamp
  • Hazardous Area Approvals
  • No
  • Hygienic/Biocompatibility Approvals
  • Yes
  • Measured Pressure Resistance
  • 70 psig @ 302 °F and 200 psig @ 122 °F (5 bar @ 150 °C and 14 bar @ 50 °C)
  • Measurement range
  • 10 - 650,000 µS/cm
  • Model Family
  • Analog
  • Primary Media/Application
  • Other Water Processes Pharmaceutical Waters Other Industrial Processes Wastewater Pharmaceutical/Life Science Production
  • Temperature Sensor
  • PT 1000
METL58031248 Cond Sensor 1.5Tri 4E SS PEEK VP 12 Special offer 
Add to Cart
  • Connection
  • VP (IP 68) , 1.5 inch Tri-Clamp
  • Hazardous Area Approvals
  • No
  • Hygienic/Biocompatibility Approvals
  • Yes
  • Measured Pressure Resistance
  • 70 psig @ 302 °F and 200 psig @ 122 °F (5 bar @ 150 °C and 14 bar @ 50 °C)
  • Measurement range
  • 10 - 650,000 µS/cm
  • Model Family
  • Analog
  • Primary Media/Application
  • Other Water Processes Pharmaceutical Waters Other Industrial Processes Wastewater Pharmaceutical/Life Science Production
  • Temperature Sensor
  • PT 1000
METL58031248 Cond Sensor 1.5Tri 4E SS PEEK VP 12 Special offer 
Add to Cart
  • Connection
  • VP (IP 68) , 1.5 inch Tri-Clamp
  • Hazardous Area Approvals
  • No
  • Hygienic/Biocompatibility Approvals
  • Yes
  • Measured Pressure Resistance
  • 70 psig @ 302 °F and 200 psig @ 122 °F (5 bar @ 150 °C and 14 bar @ 50 °C)
  • Measurement range
  • 10 - 650,000 µS/cm
  • Model Family
  • Analog
  • Primary Media/Application
  • Other Water Processes Pharmaceutical Waters Other Industrial Processes Wastewater Pharmaceutical/Life Science Production
  • Temperature Sensor
  • PT 1000
METL58031240 Cond Sensor 1NPT 4E CPVC SS VP Special offer 
Add to Cart
  • Connection
  • VP (IP68), 1 inch NPT
  • Hazardous Area Approvals
  • No
  • Hygienic/Biocompatibility Approvals
  • No
  • Measured Pressure Resistance
  • 50 psig @ 176 °F and 100 psig @ 77 °F (3.5 bar @ 80 °C and 7 bar @ 25 °C)
  • Measurement range
  • 10 - 650,000 µS/cm
  • Model Family
  • Analog
  • Primary Media/Application
  • Other Water Processes Pharmaceutical Waters Other Industrial Processes Wastewater Pharmaceutical/Life Science Production
  • Temperature Sensor
  • PT 1000
METL58031240 Cond Sensor 1NPT 4E CPVC SS VP Special offer 
Add to Cart
  • Connection
  • VP (IP68), 1 inch NPT
  • Hazardous Area Approvals
  • No
  • Hygienic/Biocompatibility Approvals
  • No
  • Measured Pressure Resistance
  • 50 psig @ 176 °F and 100 psig @ 77 °F (3.5 bar @ 80 °C and 7 bar @ 25 °C)
  • Measurement range
  • 10 - 650,000 µS/cm
  • Model Family
  • Analog
  • Primary Media/Application
  • Other Water Processes Pharmaceutical Waters Other Industrial Processes Wastewater Pharmaceutical/Life Science Production
  • Temperature Sensor
  • PT 1000
METL58031239 Cond Sensor 1NPT 4E PEEK C22 VP Special offer 
Add to Cart
  • Connection
  • VP (IP68), 1 inch NPT
  • Hazardous Area Approvals
  • No
  • Hygienic/Biocompatibility Approvals
  • No
  • Measured Pressure Resistance
  • 100 psig @ 200 °F and 200 psig @ 77 °F (7 bar @ 93 °C and 14 bar @ 25 °C)
  • Measurement range
  • 10 - 650,000 µS/cm
  • Model Family
  • Analog
  • Primary Media/Application
  • Other Water Processes Pharmaceutical Waters Other Industrial Processes Wastewater Pharmaceutical/Life Science Production
  • Temperature Sensor
  • PT 1000
METL58031239 Cond Sensor 1NPT 4E PEEK C22 VP Special offer 
Add to Cart
  • Connection
  • VP (IP68), 1 inch NPT
  • Hazardous Area Approvals
  • No
  • Hygienic/Biocompatibility Approvals
  • No
  • Measured Pressure Resistance
  • 100 psig @ 200 °F and 200 psig @ 77 °F (7 bar @ 93 °C and 14 bar @ 25 °C)
  • Measurement range
  • 10 - 650,000 µS/cm
  • Model Family
  • Analog
  • Primary Media/Application
  • Other Water Processes Pharmaceutical Waters Other Industrial Processes Wastewater Pharmaceutical/Life Science Production
  • Temperature Sensor
  • PT 1000
METL58031245 Cond Sensor 1.5Tri 4E Hast PEEK VP Special offer 
Add to Cart
  • Connection
  • VP (IP 68) , 1.5 inch Tri-Clamp
  • Hazardous Area Approvals
  • No
  • Hygienic/Biocompatibility Approvals
  • Yes
  • Measured Pressure Resistance
  • 70 psig @ 302 °F and 200 psig @ 122 °F (5 bar @ 150 °C and 14 bar @ 50 °C)
  • Measurement range
  • 10 - 650,000 µS/cm
  • Model Family
  • Analog
  • Primary Media/Application
  • Other Water Processes Pharmaceutical Waters Other Industrial Processes Wastewater Pharmaceutical/Life Science Production
  • Temperature Sensor
  • PT 1000
METL58031245 Cond Sensor 1.5Tri 4E Hast PEEK VP Special offer 
Add to Cart
  • Connection
  • VP (IP 68) , 1.5 inch Tri-Clamp
  • Hazardous Area Approvals
  • No
  • Hygienic/Biocompatibility Approvals
  • Yes
  • Measured Pressure Resistance
  • 70 psig @ 302 °F and 200 psig @ 122 °F (5 bar @ 150 °C and 14 bar @ 50 °C)
  • Measurement range
  • 10 - 650,000 µS/cm
  • Model Family
  • Analog
  • Primary Media/Application
  • Other Water Processes Pharmaceutical Waters Other Industrial Processes Wastewater Pharmaceutical/Life Science Production
  • Temperature Sensor
  • PT 1000