Our columns represent a leap forward in performance, delivering low bleed and superior inertness. Select from our comprehensive portfolio of Thermo Scientific GC columns that meet all of your analytical needs and achieve reliable, reproducible results for your gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS) applications.  


Catalog No. Product Net Price
THM26081-4960 TraceGOLD TG-VRX GC Column, 40 m x 0.18 mm x 1.00 µm Special offer 
Add to Cart
  • Polarity
  • Non-Polar
  • Diameter (Metric)
  • 0.18 mm
  • For Use With
  • 40 m
  • Temperature
  • 260°C
  • Stationary Phase
  • TraceGOLD™ TG-VRX
  • Product Line
  • TraceGOLD
  • Phase
  • TraceGOLD™ TG-VRX
  • Unit Size
  • Each
  • Description
  • 40 m x 0.18 mm x 1.00 µm
  • For Use With (Application)
  • GC/MS for Volatile Organic Pollutants, GC/MS for US EPA Method 8021 Compounds
  • Diameter (Metric) Inner
  • 0.18 mm
  • Max. Temperature
  • 260°C
  • Film Thickness
  • 1 µm
THM26096-1425 TraceGOLD™ TG-5SILMS Guard GC Column with SafeGuard, 0.25μm, 30m length, 0.25mm I.D., with 5m SafeGuard 650 
Add to Cart
  • Diameter (Metric)
  • 0.25 mm
  • For Use With
  • 30 m
  • Length (Metric)
  • 0.25 μm
  • Temperature
  • 330/350°C
  • USP Type
  • G27, G36
  • Stationary Phase
  • TG-5 SILMS
  • Product Line
  • TraceGOLD
  • Phase
  • TG-5 SILMS
  • Unit Size
  • Each
  • Type
  • G27, G36
  • Description
  • 0.25μm, 30m length, 0.25mm I.D., with 5m SafeGuard
  • For Use With (Application)
  • GC/MS Applications Using Ion-Trap Systems, GC/MS for Polycyclic Aromatics, Phthalates, Phenols, Amines, and Organophosphates, GC/MS for Hydrocarbons Including Chlorinated Hydrocarbons
  • Diameter (Metric) Inner
  • 0.25 mm
  • Max. Temperature
  • 330/350°C
  • Film Thickness
  • 0.25 µm
THM260961301 TraceGOLD™ TG-5SILMS Guard GC Column with SafeGuard, 0.25um, 15m length, with 10m SafeGuard 671 
Add to Cart
  • Diameter (Metric)
  • 0.25 mm
  • For Use With
  • 15 m
  • Length (Metric)
  • 0.25 μm
  • Temperature
  • 330/350°C
  • USP Type
  • G27, G36
  • Stationary Phase
  • TG-5 SILMS
  • Product Line
  • TraceGOLD
  • Phase
  • TG-5 SILMS
  • Unit Size
  • Each
  • Type
  • G27, G36
  • Description
  • 0.25um; 15m length; with 10m SafeGuard
  • For Use With (Application)
  • GC/MS Applications Using Ion-Trap Systems, GC/MS for Polycyclic Aromatics, Phthalates, Phenols, Amines, and Organophosphates, GC/MS for Hydrocarbons Including Chlorinated Hydrocarbons
  • Diameter (Metric) Inner
  • 0.25 mm
  • Max. Temperature
  • 330/350°C
  • Film Thickness
  • 0.25 µm
  • Temperature Range
  • -60°C to +350°C
THM260962235 TraceGOLD™ TG-5SILMS Guard GC Column with SafeGuard, 0.50um, 0.25mm ID, with 5m SafeGuard 671 
Add to Cart
  • Diameter (Metric)
  • 0.25 mm
  • For Use With
  • 30 m
  • Length (Metric)
  • 0.5 μm
  • Temperature
  • 330/350°C
  • USP Type
  • G27, G36
  • Stationary Phase
  • TG-5 SILMS
  • Product Line
  • TraceGOLD
  • Phase
  • TG-5 SILMS
  • Unit Size
  • Each
  • Type
  • G27, G36
  • Description
  • 0.50um; 0.25mm ID; with 5m SafeGuard
  • For Use With (Application)
  • GC/MS Applications Using Ion-Trap Systems, GC/MS for Polycyclic Aromatics, Phthalates, Phenols, Amines, and Organophosphates, GC/MS for Hydrocarbons Including Chlorinated Hydrocarbons
  • Diameter (Metric) Inner
  • 0.25 mm
  • Max. Temperature
  • 330/350°C
  • Film Thickness
  • 0.5 µm
  • Temperature Range
  • -60°C to +350°C
THM260962245 TraceGOLD™ TG-5SILMS Guard GC Column with SafeGuard, 0.50um, 0.32mm ID, with 5m SafeGuard 671 
Add to Cart
  • Diameter (Metric)
  • 0.32 mm
  • For Use With
  • 30 m
  • Length (Metric)
  • 0.5 μm
  • Temperature
  • 330/350°C
  • USP Type
  • G27, G36
  • Stationary Phase
  • TG-5 SILMS
  • Phase
  • TG-5 SILMS
  • Unit Size
  • Each
  • Type
  • G27, G36
  • Description
  • 0.50um; 0.32mm ID; with 5m SafeGuard
  • For Use With (Application)
  • GC/MS Applications Using Ion-Trap Systems, GC/MS for Polycyclic Aromatics, Phthalates, Phenols, Amines, and Organophosphates, GC/MS for Hydrocarbons Including Chlorinated Hydrocarbons
  • Diameter (Metric) Inner
  • 0.32 mm
  • Max. Temperature
  • 330/350°C
  • Film Thickness
  • 0.5 µm
  • Temperature Range
  • -60°C to +350°C
THM26096-1421 TraceGOLD™ TG-5SILMS Guard GC Column with SafeGuard, 0.25μm, 30m length, 0.25mm I.D with 10m SafeGuard 671 
Add to Cart
  • Diameter (Metric)
  • 0.25 mm
  • For Use With
  • 30 m
  • Length (Metric)
  • 0.25 μm
  • Temperature
  • 330/350°C
  • USP Type
  • G27, G36
  • Stationary Phase
  • TG-5 SILMS
  • Product Line
  • TraceGOLD
  • Phase
  • TG-5 SILMS
  • Unit Size
  • Each
  • Type
  • G27, G36
  • Description
  • 0.25μm; 30m length; 0.25mm I.D with 10m SafeGuard
  • For Use With (Application)
  • GC/MS Applications Using Ion-Trap Systems, GC/MS for Polycyclic Aromatics, Phthalates, Phenols, Amines, and Organophosphates, GC/MS for Hydrocarbons Including Chlorinated Hydrocarbons
  • Diameter (Metric) Inner
  • 0.25 mm
  • Max. Temperature
  • 330/350°C
  • Film Thickness
  • 0.25 µm
THM260962235 TraceGOLD™ TG-5SILMS Guard GC Column with SafeGuard, 0.50um, 0.25mm ID, with 5m SafeGuard Special offer 
Add to Cart
  • Polarity
  • Low-Polar
  • Diameter (Metric)
  • 0.25 mm
  • For Use With
  • 30 m
  • Length (Metric)
  • 0.5 μm
  • Temperature
  • 330/350°C
  • USP Type
  • G27, G36
  • Stationary Phase
  • TG-5 SILMS
  • Product Line
  • TraceGOLD
  • Phase
  • TG-5 SILMS
  • Unit Size
  • Each
  • Type
  • G27, G36
  • Description
  • 0.50um; 0.25mm ID; with 5m SafeGuard
  • For Use With (Application)
  • GC/MS Applications Using Ion-Trap Systems, GC/MS for Polycyclic Aromatics, Phthalates, Phenols, Amines, and Organophosphates, GC/MS for Hydrocarbons Including Chlorinated Hydrocarbons
  • Diameter (Metric) Inner
  • 0.25 mm
  • Max. Temperature
  • 330/350°C
  • Film Thickness
  • 0.5 µm
THM260962245 TraceGOLD™ TG-5SILMS Guard GC Column with SafeGuard, 0.50um, 0.32mm ID, with 5m SafeGuard Special offer 
Add to Cart
  • Polarity
  • Low-Polar
  • Diameter (Metric)
  • 0.32 mm
  • For Use With
  • 30 m
  • Length (Metric)
  • 0.5 μm
  • Temperature
  • 330/350°C
  • USP Type
  • G27, G36
  • Stationary Phase
  • TG-5 SILMS
  • Phase
  • TG-5 SILMS
  • Unit Size
  • Each
  • Type
  • G27, G36
  • Description
  • 0.50um; 0.32mm ID; with 5m SafeGuard
  • For Use With (Application)
  • GC/MS Applications Using Ion-Trap Systems, GC/MS for Polycyclic Aromatics, Phthalates, Phenols, Amines, and Organophosphates, GC/MS for Hydrocarbons Including Chlorinated Hydrocarbons
  • Diameter (Metric) Inner
  • 0.32 mm
  • Max. Temperature
  • 330/350°C
  • Film Thickness
  • 0.5 µm
THM-260Q142P TRACE™ TR-1701 GC Column, 30 m x 0.25 mm x 0.25 µm 502 
Add to Cart
  • Diameter (Metric)
  • 0.25 mm
  • For Use With
  • 30 m
  • Temperature
  • 280/300°C
  • USP Type
  • G46
  • Stationary Phase
  • Trace™ TR-1701
  • Product Line
  • TRACE
  • Phase
  • Trace™ TR-1701
  • Unit Size
  • Each
  • Type
  • G46
  • Description
  • 30 m x 0.25 mm x 0.25 µm
  • For Use With (Application)
  • GC/MS for Pesticides, PCBs, PAHs, and Organic Acids, GC/MS for Drugs and Steroids, GC/MS for EPA 608, 8081
  • Diameter (Metric) Inner
  • 0.25 mm
  • Max. Temperature
  • 280/300°C
  • Film Thickness
  • 0.25 µm
THM-260Q298P TRACE™ TR-1701 GC Column, 30 m x 0.53 mm x 1 µm 502 
Add to Cart
  • Diameter (Metric)
  • 0.53 mm
  • For Use With
  • 30 m
  • Temperature
  • 280/300°C
  • USP Type
  • G46
  • Stationary Phase
  • Trace™ TR-1701
  • Product Line
  • TRACE
  • Phase
  • Trace™ TR-1701
  • Unit Size
  • Each
  • Type
  • G46
  • Description
  • 30 m x 0.53 mm x 1 µm
  • For Use With (Application)
  • GC/MS for Pesticides, PCBs, PAHs, and Organic Acids, GC/MS for Drugs and Steroids, GC/MS for EPA 608, 8081
  • Diameter (Metric) Inner
  • 0.53 mm
  • Max. Temperature
  • 280/300°C
  • Film Thickness
  • 1 µm

Overview

Popular high-performance gas chromatography columns


* TraceGOLD TG-WaxMS GC Columns with SafeGuard

* TraceGOLD TG-5SilMS GC Columns

* TracePLOT TG-BOND Msieve 5A GC Columns



Resources