+852-3069 6950
sales@gugent.com.hk
 

Streamline your chromatography workflow with prepacked columns that come ready to use with chromatography resins.

Catalog No. Product Net Price
CYT29146146 ReadyToProcess Capto S ImpAct 5 L (178/200) Special offer 
Add to Cart
  • Chromatography technique
  • Ion exchange chromatography
  • Bed volume
  • 1 L
  • Pressure max. (over the packed bed during operation)
  • 3 bar (0.3 MPa, 44 psi)
  • Pack size
  • 1 L
  • Bed height
  • 200 mm (7.87 in)
  • Column i.d.
  • 80
  • Application
  • For manufacturing of biopharmaceuticals for clinical phase I and II studies. Depending on the scale of operations, they can also be used for full-scale manufacturing, as well as for preclinical studies.
  • Storage
  • 4ºC to 30ºC, 20% Ethanol, 0.2 M sodium acetate pH 5.5
  • Bed dimensions
  • 80 × 200 mm
  • Certificate of Analysis
  • Yes
CYT29212475 ReadyToProcess Capto S ImpAct 32 L (450/200) Special offer 
Add to Cart
  • Chromatography technique
  • Ion exchange chromatography
  • Bed volume
  • 1 L
  • Pressure max. (over the packed bed during operation)
  • 3 bar (0.3 MPa, 44 psi)
  • Pack size
  • 1 L
  • Bed height
  • 200 mm (7.87 in)
  • Column i.d.
  • 80
  • Application
  • For manufacturing of biopharmaceuticals for clinical phase I and II studies. Depending on the scale of operations, they can also be used for full-scale manufacturing, as well as for preclinical studies.
  • Storage
  • 4ºC to 30ºC, 20% Ethanol, 0.2 M sodium acetate pH 5.5
  • Bed dimensions
  • 80 × 200 mm
  • Certificate of Analysis
  • Yes
CYT29287577 ReadyToProcess Capto S ImpAct 0.8 L (80/150) Special offer 
Add to Cart
  • Chromatography technique
  • Ion exchange chromatography
  • Bed volume
  • 1 L
  • Pressure max. (over the packed bed during operation)
  • 3 bar (0.3 MPa, 44 psi)
  • Pack size
  • 1 L
  • Bed height
  • 200 mm (7.87 in)
  • Column i.d.
  • 80
  • Application
  • For manufacturing of biopharmaceuticals for clinical phase I and II studies. Depending on the scale of operations, they can also be used for full-scale manufacturing, as well as for preclinical studies.
  • Storage
  • 4ºC to 30ºC, 20% Ethanol, 0.2 M sodium acetate pH 5.5
  • Bed dimensions
  • 80 × 200 mm
  • Certificate of Analysis
  • Yes
CYT29376130 ReadyToProcess Capto S ImpAct 57 L (600/200) Special offer 
Add to Cart
  • Chromatography technique
  • Ion exchange chromatography
  • Bed volume
  • 1 L
  • Pressure max. (over the packed bed during operation)
  • 3 bar (0.3 MPa, 44 psi)
  • Pack size
  • 1 L
  • Bed height
  • 200 mm (7.87 in)
  • Column i.d.
  • 80
  • Application
  • For manufacturing of biopharmaceuticals for clinical phase I and II studies. Depending on the scale of operations, they can also be used for full-scale manufacturing, as well as for preclinical studies.
  • Storage
  • 4ºC to 30ºC, 20% Ethanol, 0.2 M sodium acetate pH 5.5
  • Bed dimensions
  • 80 × 200 mm
  • Certificate of Analysis
  • Yes
CYT29101661 ReadyToProcess Capto SP ImpRes 1 L (80/200) 11848 
Add to Cart
  • Chromatography technique
  • Ion exchange chromatography
  • Bed volume
  • 1 L
  • Pressure max. (over the packed bed during operation)
  • 3 bar [0.3 MPa] (44 psi)
  • Pack size
  • 1 L
  • Bed height
  • 200 mm (7.87 in)
  • Column i.d.
  • 80
  • Application
  • For manufacturing of biopharmaceuticals for clinical phase I and II studies. Depending on the scale of operations, they can also be used for full-scale manufacturing, as well as for preclinical studies.
  • Storage
  • 4°C-30°C, 20% EtOH + 0.2 M Sodium Acetate
  • Bed dimensions
  • 80 × 200 mm
  • Certificate of Analysis
  • Yes
CYT29101662 ReadyToProcess Capto SP ImpRes 2.5 L (126/200) Special offer 
Add to Cart
  • Chromatography technique
  • Ion exchange chromatography
  • Bed volume
  • 1 L
  • Pressure max. (over the packed bed during operation)
  • 3 bar [0.3 MPa] (44 psi)
  • Pack size
  • 1 L
  • Bed height
  • 200 mm (7.87 in)
  • Column i.d.
  • 80
  • Application
  • For manufacturing of biopharmaceuticals for clinical phase I and II studies. Depending on the scale of operations, they can also be used for full-scale manufacturing, as well as for preclinical studies.
  • Storage
  • 4°C-30°C, 20% EtOH + 0.2 M Sodium Acetate
  • Bed dimensions
  • 80 × 200 mm
  • Certificate of Analysis
  • Yes
CYT29101663 ReadyToProcess Capto SP ImpRes 10 L (251/200) Special offer 
Add to Cart
  • Chromatography technique
  • Ion exchange chromatography
  • Bed volume
  • 1 L
  • Pressure max. (over the packed bed during operation)
  • 3 bar [0.3 MPa] (44 psi)
  • Pack size
  • 1 L
  • Bed height
  • 200 mm (7.87 in)
  • Column i.d.
  • 80
  • Application
  • For manufacturing of biopharmaceuticals for clinical phase I and II studies. Depending on the scale of operations, they can also be used for full-scale manufacturing, as well as for preclinical studies.
  • Storage
  • 4°C-30°C, 20% EtOH + 0.2 M Sodium Acetate
  • Bed dimensions
  • 80 × 200 mm
  • Certificate of Analysis
  • Yes
CYT29101665 ReadyToProcess Capto SP ImpRes 20 L (359/200) Special offer 
Add to Cart
  • Chromatography technique
  • Ion exchange chromatography
  • Bed volume
  • 1 L
  • Pressure max. (over the packed bed during operation)
  • 3 bar [0.3 MPa] (44 psi)
  • Pack size
  • 1 L
  • Bed height
  • 200 mm (7.87 in)
  • Column i.d.
  • 80
  • Application
  • For manufacturing of biopharmaceuticals for clinical phase I and II studies. Depending on the scale of operations, they can also be used for full-scale manufacturing, as well as for preclinical studies.
  • Storage
  • 4°C-30°C, 20% EtOH + 0.2 M Sodium Acetate
  • Bed dimensions
  • 80 × 200 mm
  • Certificate of Analysis
  • Yes
CYT29146147 ReadyToProcess Capto SP ImpRes 5 L (178/200) Special offer 
Add to Cart
  • Chromatography technique
  • Ion exchange chromatography
  • Bed volume
  • 1 L
  • Pressure max. (over the packed bed during operation)
  • 3 bar [0.3 MPa] (44 psi)
  • Pack size
  • 1 L
  • Bed height
  • 200 mm (7.87 in)
  • Column i.d.
  • 80
  • Application
  • For manufacturing of biopharmaceuticals for clinical phase I and II studies. Depending on the scale of operations, they can also be used for full-scale manufacturing, as well as for preclinical studies.
  • Storage
  • 4°C-30°C, 20% EtOH + 0.2 M Sodium Acetate
  • Bed dimensions
  • 80 × 200 mm
  • Certificate of Analysis
  • Yes
CYT29376128 ReadyToProcess Capto SP ImpRes 57L (600/200) Special offer 
Add to Cart
  • Chromatography technique
  • Ion exchange chromatography
  • Bed volume
  • 1 L
  • Pressure max. (over the packed bed during operation)
  • 3 bar [0.3 MPa] (44 psi)
  • Pack size
  • 1 L
  • Bed height
  • 200 mm (7.87 in)
  • Column i.d.
  • 80
  • Application
  • For manufacturing of biopharmaceuticals for clinical phase I and II studies. Depending on the scale of operations, they can also be used for full-scale manufacturing, as well as for preclinical studies.
  • Storage
  • 4°C-30°C, 20% EtOH + 0.2 M Sodium Acetate
  • Bed dimensions
  • 80 × 200 mm
  • Certificate of Analysis
  • Yes

Overview

Affinity antibody

Prepacked protein A columns, protein G columns, and other antibody affinity purification products


Affinity specific groups

Affinity chromatography products for purification of proteins or other biomolecules from complex mixtures.


Affinity tagged protein

Purification of tagged proteins including fusions with GST, histidine, Strep-tag™ II, and MBP


Desalting and buffer exchange

Desalting columns remove salts from biological samples prior to further purification or end use.


Hydrophobic interaction

Use prepacked HIC chromatography columns for protein capture, intermediate purification, or polishing steps.


Immunoprecipitation

Use immunoprecipitation columns to isolate small amounts of target proteins


Ion exchange

Use ion exchange columns to enhance your biomolecule purification processes


Multimodal columns

Use multimodal or mixed mode chromatography for increased selectivity, high salt conditions, or process efficiency.


Reversed phase

Reverse phase chromatography columns for high-resolution separations


Size exclusion

Use size exclusion columns to separate proteins and other biomolecules based on size and shape.



Resources