+852-3069 6950
sales@gugent.com.hk
 

Chromatography equipment and accessories

Column accessories, filters, sample loops, pumps, fraction collectors, and more equipment for chromatography systems.


Catalog No. Product Net Price
CYT28404225 Hg lamp and housing complete 1628 
Add to Cart
  • Wetted Part
  • No
  • Guidance
  • Lamp and aperture are supplied with Hg lamp and housing
CYT19785001 Superloop, M6 fitting, 50 ml 1684 
Add to Cart
  • Flow rate
  • < 100 ml/min, 10 ml/min when emptying completely
  • Dimensions
  • 130 x 30 mm
  • Material
  • Borosilicate glass\nPolyetheretherketone (PEEK)\nPerfluor rubber (PFR)\nNitrilebutadiene rubber (NBR)
  • Connections
  • 1/16\
  • Operating pressure max.
  • 40 bar (4 MPa) (580 psi)
  • Operating Temperature
  • 4°C-40°C
  • Chemical stability
  • For use with aqueous solutions and alcohols. Accessory O-rings, solvent resistant, permit use with organic solvents such as acetonitrile and organic esters
  • Wetted Materials
  • Borosilicate glass\nPolyetheretherketone (PEEK)\nPerfluor rubber (PFR)\nNitrilebutadiene rubber (NBR)
  • Wetted Part
  • Yes
  • Guidance
  • .
  • Includes
  • 1 x Tubing i.d. 0.75 mm o.d. 1/16\
  • pH Stability Short Term
  • 1(<1 day exposure)–14(<1 day exposure)
CYT18111928 Manometer Kit, 0-6 bar 1710 
Add to Cart
  • Material
  • Ethylene propylene diene (EPDM)\nStainless steel (304)\nStainless Steel (316)
  • Connections
  • 2 x 25 mm TC, 1 x 50 mm TC, horizontal
  • Operating pressure max.
  • 10 bar
  • Wetted Part
  • Yes
  • Application
  • For packing or running the column
  • Guidance
  • Optional for packing or running the column.
  • Kit contents
  • Pressure gauge\nT-junction (2 x 25 mm TC, 1 x 50 mmTC)\n2 x 25 mm clamps\n1 x 50 mm clamp\n2 x 25 mm gaskets (Ethylene propylene diene)\n1 x 50 mm gasket (Ethylene propylene diene)
CYT18111105 Conductivity Flow Cell 1731 
Add to Cart
  • Material
  • Titanium (Ti)\nChlorotrifluoroethylene (CTFE)
  • Connections
  • UNF 10–32 2B ”Fingertights” with capillary tubing 1/\n16\
  • Operating pressure max.
  • 50 bar (5 MPa) (725 psi)
  • Chemical stability
  • The wetted parts are resistant to organic solvents and salt buffers commonly used in chromatography of biomolecules, except \n100 % Ethyl acetate, \n100 % Hexane and \n100 % Tetrahydrofuran
  • Wetted Materials
  • Titanium (Ti) Chlorotrifluoroethylene (CTFE)
  • Wetted Part
  • Yes
  • pH Stability Short Term
  • 1–14
CYT28994472 Manometer Kit 0-6 Bar 1762 
Add to Cart
  • Material
  • Ethylene propylene diene (EPDM)\nStainless steel (304)\nStainless Steel (316)
  • Connections
  • 2 x 25 mm TC, 1 x 50 mm TC, horizontal
  • Operating pressure max.
  • 10 bar
  • Wetted Part
  • Yes
  • Application
  • For packing or running the column
  • Guidance
  • Optional for packing or running the column.
  • Kit contents
  • Pressure gauge\nT-junction (2 x 25 mm TC, 1 x 50 mmTC)\n2 x 25 mm clamps\n1 x 50 mm clamp\n2 x 25 mm gaskets (Ethylene propylene diene)\n1 x 50 mm gasket (Ethylene propylene diene)
CYT28978006 Safety Valves, 6 bar rupture disc kit for AxiChrom 200 1898 
Add to Cart
  • Material
  • Ethylene propylene diene (EPDM)\nStainless steel (316)
  • Connections
  • Inlet: 50 mm TC \nOutlet: 50 mm TC
  • Operating pressure max.
  • 8 bar (116 psi)
  • Order Information
  • 1 x T-junction, 2 x clamp 25 mm, 2 x gasket 25 mm, 2 x clamp 51 mm and 2 x gasket 51 mm have to be ordered separately.
  • Wetted Part
  • Yes
  • Guidance
  • Optional for packing or running the column.\n\nNote that tubing with i.d. 19 mm and 51 mm TC should be connected to the relief outlet.
CYT28978012 Safety Valves, 8 bar rupture disc kit for AxiChrom 140 1901 
Add to Cart
  • Material
  • Ethylene propylene diene (EPDM)\nStainless steel (316)
  • Connections
  • Inlet: 50 mm TC \nOutlet: 50 mm TC
  • Operating pressure max.
  • 8 bar (116 psi)
  • Order Information
  • 1 x T-junction, 2 x clamp 25 mm, 2 x gasket 25 mm, 2 x clamp 51 mm and 2 x gasket 51 mm have to be ordered separately.
  • Wetted Part
  • Yes
  • Guidance
  • Optional for packing or running the column.\n\nNote that tubing with i.d. 19 mm and 51 mm TC should be connected to the relief outlet.
CYT18111889 Mixer M-925 for classic 1929 
Add to Cart
  • Flow rate
  • 0.001-100 ml/min
  • Pack size
  • 1
  • Material
  • Polyetheretherketone (PEEK),\nPolytetrafluoroethylene (PTFE)
  • Compliance
  • The product fulfills valid directives and standards when used within the conditions specified in the user manual. The product must also be used in the same state as it was delivered from Cytiva and connected only to other CE labeled Cytiva modules or other products as recommended. For regulatory details please see declaration of conformity.
  • Operating pressure max.
  • 100 bar (10 MPa) at 0.1 to 100 ml/min (12 ml chambers)\n250 bar (25 MPa) at 0.001 to 100 ml/min (0.6, 2 and 5 ml chambers)\n350 bar (35 MPa) at 0.001 to 5 ml/min (90 μl and 0.2 ml chambers) (1450 psi at 0.1 to 100 ml/min (12 ml chambers)\n3625 psi at 0.001 to 100 ml/min (0.6, 2 and 5 ml chambers)\n5075 psi at 0.001 to 5 ml/min (90 μl and 0.2 ml chambers))
  • Operating Temperature
  • 4°C-40°C
  • Weight
  • 1.2
  • Height
  • 152 mm
  • Wetted Part
  • No
  • Includes
  • One UniNet cable is supplied with the mixer.
  • Power consumption
  • 1 VA
  • Relative humidity
  • 20%-95% (non condensing)
  • Width
  • 77
  • Depth
  • 111 mm
  • Protection class
  • IP 43
  • pH Stability Long Term
  • 1-13
  • pH Stability Short Term
  • 1–14
  • Power requirements
  • 12 to 40 V DC from the pump
  • Viscosity Max.
  • 5
CYT18101686 NovaBlot Kit 2018 
Add to Cart
  • Pack size
  • 1 kit
  • For use with
  • Multiphor II
  • Wetted Part
  • No
  • Application
  • Electrophoretic transfer
  • Kit contents
  • 1 x Electrode cathode, NovaBlot\n1 x Electrode anode, NovaBlot\n500 x Electrode paper (200x250mm), NovaBlot\n50 x Cellophane sheet (210x320 mm)
CYT29011361 I/O-box E9 2092 
Add to Cart
  • Wetted Part
  • No