Catalog No. Product Net Price
CYT11000566 Peristaltic Pump, 110 VAC Special offer 
Add to Cart
  • Flow rate
  • < 13 l/min with tubing i.d. 12.7 mm (0.5 inch)
  • Material
  • Tubing: Thermoplastic elastomer (TPE\nBioprene)
  • Wetted Part
  • Yes
  • Includes
  • Single head pump with variable-speed drive for flow rates 0.4 - 13 l/min with tubing i.d. 12.7 mm (0.5 inch), supplied with the pump.
  • Voltage
  • 110 VAC
  • Material Compliance
  • USP Class VI
CYT11000567 Peristaltic Pump, 220 VAC Special offer 
Add to Cart
  • Flow rate
  • < 13 l/min with tubing i.d. 12.7 mm (0.5 inch)
  • Material
  • Tubing: Thermoplastic elastomer (TPE\nBioprene)
  • Wetted Part
  • Yes
  • Includes
  • Single head pump with variable-speed drive for flow rates 0.4 - 13 l/min with tubing i.d. 12.7 mm (0.5 inch), supplied with the pump.
  • Voltage
  • 110 VAC
  • Material Compliance
  • USP Class VI
CYT11000870 Tubing Connector Special offer 
Add to Cart
  • Material
  • Acetal plastic
  • Wetted Part
  • Yes
CYT18100422 Pen, short-nib blue Special offer 
Add to Cart
  • Application
  • Short-nib pen (blue) to use with paper chart recorder REC-111 or REC-112
CYT18111400 Pump P-901 Special offer 
Add to Cart
  • Flow rate
  • 0.01-100 ml/min
  • Material
  • Polyetheretherketone (PEEK)\nPolytetrafluoroethylene (PTFE)\nEthylenechlorotrifluoro-ethylene (ECTFE)\nPolyvinylidenefluoride(PVDF)\nPolyethylene (PE)\nTitanium\nTitanium alloy (Ti alloy)\nAluminium oxide (Al oxide)\nRuby\nZirconia\nSuper high resistent stainless steel
  • Compliance
  • The product fulfills valid directives and standards when used within the conditions specified in the user manual. The product must also be used in the same state as it was delivered from Cytiva and connected only to other CE labeled Cytiva modules or other products as recommended. For regulatory details please see declaration of conformity.
  • Connections
  • Fingertight connector
  • Operating pressure max.
  • 100 bar (10 MPa) (1450 psi)
  • Operating Temperature
  • 4°C-40°C
  • Weight
  • 17
  • Chemical stability
  • The wetted parts are resistant to organic solvents and salt buffers commonly used in chromatography of biomolecules, except 100% Ethylacetate, 100% Hexane, and 100 % Tetrahydrofuran (THF).
  • Height
  • 150 mm
  • Wetted Materials
  • Polyetheretherketone (PEEK)\nPolytetrafluoroethylene (PTFE)\nEthylenechlorotrifluoro-ethylene (ECTFE)\nPolyvinylidenefluoride(PVDF)\nPolyethylene (PE)\nTitanium\nTitanium alloy (Ti alloy)\nAluminium oxide (Al oxide)\nRuby\nZirconia\nSuper high resistent stainless steel
  • Wetted Part
  • Yes
  • Includes
  • Pump with 4 pump heads, inlet filter assembly, inlet tubing kit [1/82], tubing kit for rinsing system, mixer M-925, mixer chamber [2.0 ml with pump P-901 and 0.6 ml with pump P-903], mixer bracket, PEEK tubing [2 m, 0.5 mm i.d., 1/162 o.d.), fingertight connector [1/162], injection syringe 30 ml, stop plug [1/162] and a signal cable
  • Power consumption
  • Max. 400 VA with all extra components connected
  • Relative humidity
  • 20%-95% (non condensing)
  • Width
  • 260
  • Depth
  • 370 mm
  • Voltage
  • 100-120/220-240 V AC
  • Protection class
  • IP 20 (Housing)
  • pH Stability Long Term
  • 1-13
  • pH Stability Short Term
  • 1–14
  • Viscosity Max.
  • 5
CYT18112895 UPC-900 Control Unit Special offer 
Add to Cart
  • Voltage
  • 100-120/220-240 VAC
CYT18114711 Sleeves, i.d. 203 Special offer 
Add to Cart
  • Material
  • Polyetheretherketone (PEEK)
  • Wetted Part
  • Yes
  • Guidance
  • For capillary i.d. 0.1 mm
  • i.d.
  • 203 µm
CYT18114712 Sleeves, i.d. 381 Special offer 
Add to Cart
  • Material
  • Polyetheretherketone (PEEK)
  • Wetted Part
  • Yes
  • Guidance
  • For capillary i.d. 0.1 mm
  • i.d.
  • 203 µm
CYT18114715 Loop, 1 Special offer 
Add to Cart
  • Material
  • Polyetheretherketone (PEEK)\nSilica
  • Connections
  • 1/16\
  • Chemical stability
  • The wetted parts are resistant to organic solvents and salt buffers commonly used in chromatography of biomolecules, except 100 % Ethyl acetate, 100 % Hexane and 100 % Tetrahydrofuran.
  • Wetted Materials
  • Polyetheretherketone (PEEK)\nSilica
  • Wetted Part
  • Yes
  • Includes
  • 2 x Fingertight narrow head connector 1/16\
CYT18114716 Loop, 10 Special offer 
Add to Cart
  • Material
  • Polyetheretherketone (PEEK)\nSilica
  • Connections
  • 1/16\
  • Chemical stability
  • The wetted parts are resistant to organic solvents and salt buffers commonly used in chromatography of biomolecules, except 100 % Ethyl acetate, 100 % Hexane and 100 % Tetrahydrofuran.
  • Wetted Materials
  • Polyetheretherketone (PEEK)\nSilica
  • Wetted Part
  • Yes
  • Includes
  • 2 x Fingertight narrow head connector 1/16\