+852-3069 6950
sales@gugent.com.hk
 

Water or air, measure H2S where it matters – right at the source.


Meet the new GS1440 and GS1440EX hydrogen sulfide sensors from Hach. Whether in water or air, you will have the direct H2S measurement you need to optimize your H2S treatment process and proactively control H2S before it causes issues.

Catalog No. Product Net Price
HACH32301.B Electrochemical sensor cleaning and regeneration unit, 230 VAC 2214 
Add to Cart
LZX867 Flow through unit for NT3100 sc/NT3200 sc 5 mm, Nitratax plus sc 5 mm, Uvas plus sc 5 mm probe 2805 
Add to Cart
  • Cable Length
  • 10 m
  • Length
  • 333 mm
  • Material
  • Measuring cell: PVC; Glands: PVDF; Sample tube: PVC; Screws: Stainless Steel; Seals: EPDM
  • Operating Temperature Range
  • 2 - 40 °C (sample temperature)
  • Pressure Range
  • Not pressurized, open drain
  • Sample Volume
  • 0.5 - 10 L
  • Weight
  • 3.6 kg
LZX869 Flow through unit for NT3100sc/NT3200sc 1/2 mm, Nitratax plus sc 2 mm, Uvas plus sc 2 mm probe 2805 
Add to Cart
  • Length
  • 333 mm
  • Material
  • Measuring cell: PVC; Glands: PVDF; Sample tube: PVC; Screws: Stainless Steel; Seals: EPDM
  • Operating Temperature Range
  • 2 - 40 °C (sample temperature)
  • Pressure Range
  • Not pressurized, open drain
  • Sample Volume
  • 0.5 - 10 L
  • Weight
  • 3.6 kg
DG33302 410/510 Panel mounting 2 flow Special offer 
Add to Cart
LZY499 Cable Kit for High Output Airblast Special offer 
Add to Cart
LZY995 Modem Kit, Verizon Special offer 
Add to Cart
HACH2934GP Polishing cloth for use with 2933 polishing powder. Special offer 
Add to Cart
DPD1P1Q06 Hach pHD sc Online Process pH Sensor - General Purpose pH Sensor Special offer 
Add to Cart
  • Body Material
  • PEEK
  • Length
  • 271.3 mm
  • Operating Temperature Range
  • -5 - 70 °C (23 - 158 °F) pHD and ORP0 - 50 °C (32 - 122 °F) SS pHDBefore initial pH calibration, calibrate the temperature measurement when the sensor is in water or buffer which is at approximately the same temperature as the pH buffers (matches current recommendation)
  • Pressure Range
  • Maximum 10.7 bar . 6.9 bar for Digital Sensor at 70°C, and 6.9 bar for Analog Sensor at 105°C.
  • Range
  • -2.0 to 14.0 pH-1500 to +1500 mV ORP
  • Repeatability
  • ± 0.05 pH
  • Storage Conditions
  • 4 - 70°C, 0-95% relative humidity (non-condensing)
  • Warranty
  • 12 months
  • Weight
  • 0.316 kg
DPD1P1.1 Digital pH Sensor, PEEK, Convertible, Non-Hazardous Environment 1161 
Add to Cart
  • Body Material
  • PEEK
  • Cable Length
  • 10m (33 ft.)
  • Calibration Method
  • Two point automatic, one point automatic, two point manual, one point manual
  • Length
  • 271.3 mm
  • Mounting
  • Convertible
  • Operating Temperature Range
  • -5 - 70 °C (23 - 158 °F) pHD and ORP0 - 50 °C (32 - 122 °F) SS pHDBefore initial pH calibration, calibrate the temperature measurement when the sensor is in water or buffer which is at approximately the same temperature as the pH buffers (matches current recommendation)Please Note:When the sensor is placed into the application sample, if that sample is more than 10 °C (18 °F) different than the previous temperature/pH calibration, then it is recommended to recalibrate the temperature while the sensor is in the sample to maintain the ±0.5 °C (±0.9 °F) temperature accuracy specification.
  • Pressure Range
  • Maximum 10.7 bar. 6.9 bar for Digital Sensor at 70 °C, and 6.9 bar for Analog Sensor at 105 °C.
  • Range
  • -2.0 to 14.0 pH
  • Repeatability
  • ± 0.05 pH
  • Storage Conditions
  • 4 - 70 °C, 0 - 95% relative humidity (non-condensing)
  • Warranty
  • 12 months
  • Weight
  • 0.316 kg
DPD1P1 pHD sc: Digital pH sensor with glass differential electrode, sc compatibility, PEEK®, Convertible Mount 1161 
Add to Cart
  • Body Material
  • PEEK
  • Cable Length
  • 10m (33 ft.)
  • Calibration Method
  • Two point automatic, one point automatic, two point manual, one point manual
  • Length
  • 271.3 mm
  • Mounting
  • Convertible
  • Operating Temperature Range
  • -5 - 70 °C (23 - 158 °F) pHD and ORP0 - 50 °C (32 - 122 °F) SS pHDBefore initial pH calibration, calibrate the temperature measurement when the sensor is in water or buffer which is at approximately the same temperature as the pH buffers (matches current recommendation)
  • Pressure Range
  • Maximum 10.7 bar. 6.9 bar for Digital Sensor at 70°C, and 6.9 bar for Analog Sensor at 105°C.
  • Range
  • -2.0 to 14.0 pH
  • Repeatability
  • ± 0.05 pH
  • Storage Conditions
  • 4 - 70°C, 0 - 95% relative humidity (non-condensing)
  • Warranty
  • 12 months
  • Weight
  • 0.316 kg

Related Categories