+852-3069 6950
sales@gugent.com.hk
 

Water or air, measure H2S where it matters – right at the source.


Meet the new GS1440 and GS1440EX hydrogen sulfide sensors from Hach. Whether in water or air, you will have the direct H2S measurement you need to optimize your H2S treatment process and proactively control H2S before it causes issues.

Catalog No. Product Net Price
LXV325.99.30002 TSS HT sc Turbidity and Suspended Solids Inline Probe, Stainless Steel 6882 
Add to Cart
  • Automatic Wiper
  • No
  • Cable Length
  • 10 m (optional extension cables available)
  • Calibration Method
  • Turbidity Formazin or StablCal® Standard (at 800 NTU). Requires a calibration kit. Suspended Solids Sample specific, based on gravimetric analysis with a correction factor procedure.
  • Flow
  • Max. 3 m/s (the presence of air bubbles affects the measurement)
  • Length
  • 332 mm
  • Maintenance Interval
  • 1 h/month
  • Material
  • Optics Carrier and Sleeve: stainless steel 1.4460 / stainless steel 1.4571
  • Max. cable length Sensor-to-Controller
  • 100
  • Measuring Principle
  • Turbidity: 2-channel 90° scattered light measurement in accordance with DIN EN ISO 7027TSS: Modified absorption measurementEight-channel multiple-angle measurement, wavelength = 860 nm
  • Model
  • TSS HT sc
  • Operating Temperature Range
  • 0 - 90 °C
  • Parameter
  • Turbidity, Suspended Solids
  • Pressure Range
  • < 10 bar or < 100 m
  • Range
  • Turbidity (TRB): 0.001 - 9999 NTUSolids (TSS): 0.001 - 500 g/L
  • Repeatability
  • TSS content: < 4 %Turbidity: < 3 %
  • Response Time T90
  • 1 - 300 s adjustable
  • Special Notes
  • Installation note:Distance sensor–wall > 10 cm (TSS)
  • Warranty
  • 12 months
  • Weight
  • approx. 1.6 kg
  • What's included?
  • Turbidity & Suspended Solids sensor, user manual
LXV328.99.30002 TSS EX1 sc Turbidity and Suspended Solids Inline Probe, Stainless Steel 7270 
Add to Cart
  • Automatic Wiper
  • No
  • Cable Length
  • 10 m (optional extension cables available)
  • Calibration Method
  • Turbidity Formazin or StablCal® Standard (at 800 NTU). Requires a calibration kit. Suspended Solids Sample specific, based on gravimetric analysis with a correction factor procedure.
  • Flow
  • Max. 3 m/s (the presence of air bubbles affects the measurement)
  • Length
  • 488 mm
  • Maintenance Interval
  • 1 h/month
  • Material
  • Optics Carrier and Sleeve: stainless steel 1.4460 / stainless steel 1.4404
  • Max. cable length Sensor-to-Controller
  • 100
  • Measuring Principle
  • Turbidity: 2-channel 90° scattered light measurement in accordance with DIN/EN 27027/ISO7027TSS: Modified absorption measurementEight-channel multiple-angle measurement, wavelength = 860 nm
  • Model
  • TSS EX1 sc
  • Operating Temperature Range
  • -10 - 50 °C
  • Parameter
  • Turbidity, Suspended Solids
  • Pressure Range
  • 10 bar or 100 m
  • Range
  • Turbidity (TRB): 0.001 - 9999 NTUSolids (TSS): 0.001 - 500 g/L
  • Repeatability
  • TSS content: < 4 %Turbidity: < 3 %
  • Response Time T90
  • 1 - 300 s adjustable
  • Special Notes
  • Installation note:Distance sensor–wall > 10 cm (TSS)
  • Warranty
  • 12 months
  • Weight
  • approx. 2.7 kg
  • What's included?
  • Turbidity & Suspended Solids sensor, user manual
LXV327.99.10002 TSS XL sc Turbidity and Suspended Solids Inline Probe, Stainless Steel 6882 
Add to Cart
  • Automatic Wiper
  • No
  • Cable Length
  • 10 m (optional extension cables available)
  • Calibration Method
  • Turbidity (TRB): Factory calibratedSolids (TS): To be calibrated by customer on siteZero point: Permanently calibrated in the factory
  • Flow
  • Max. 3 m/s (the presence of air bubbles affects the measurement)
  • Length
  • TSS XL sc: 232 mm
  • Maintenance Interval
  • 1 h/month
  • Material
  • Gasket: FKM; Wiper: PA (GF), TPV
  • Measuring Principle
  • Combined multiple beam alternating light method with infrared diode system and beam focusingTurbidity: 2-channel 90° scattered light measurement in accordance with DIN/EN 27027/ISO 7027, wavelength = 860 nmSolids: Modified absorption measurement; eight-channel multiple-angle measurement, wavelength = 860 nm
  • Model
  • TSS XL sc
  • Operating Temperature Range
  • 0 - 80 °C
  • Parameter
  • Turbidity, Suspended Solids
  • Pressure Range
  • 16 bar or 160 m
  • Range
  • Turbidity (TRB): 0.001 - 9999 NTUSolids (TSS): 0.001 - 500 g/L
  • Repeatability
  • TSS content: < 4 %Turbidity: < 3 %
  • Response Time T90
  • 1 - 300 s adjustable
  • Special Notes
  • Installation note:Distance sensor–wall > 50 cm (Turbidity)> 10 cm (TSS)
  • Warranty
  • 12 months
  • Weight
  • approx. 1.5 kg
  • What's included?
  • Turbidity & Suspended Solids sensor, user manual
LXV326.99.10002 TSS Vari sc Turbidity and Suspended Solids Inline probe, Stainless Steel 6882 
Add to Cart
  • Automatic Wiper
  • No
  • Cable Length
  • 10 m (optional extension cables available)
  • Calibration Method
  • Turbidity (TRB): Factory calibratedSolids (TS): To be calibrated by customer on siteZero point: Permanently calibrated in the factory
  • Flow
  • Max. 3 m/s (the presence of air bubbles affects the measurement)
  • Length
  • TSS VARI sc 232 mm
  • Maintenance Interval
  • 1 h/month
  • Material
  • Gasket: FKM; Wiper: PA (GF), TPV
  • Measuring Principle
  • Combined multiple beam alternating light method with infrared diode system and beam focusingTurbidity: 2-channel 90° scattered light measurement in accordance with DIN/EN 27027/ISO 7027, wavelength = 860 nmSolids: Modified absorption measurement; eight-channel multiple-angle measurement, wavelength = 860 nm
  • Model
  • TSS Vari sc
  • Operating Temperature Range
  • 0 - 80 °C
  • Parameter
  • Turbidity, Suspended Solids
  • Pressure Range
  • <16 bar or <160 m
  • Range
  • Turbidity (TRB): 0.001 - 9999 NTUSolids (TSS): 0.001 - 500 g/L
  • Repeatability
  • TSS content: < 4 %Turbidity: < 3 %
  • Response Time T90
  • 1 - 300 s adjustable
  • Special Notes
  • Installation note:Distance sensor–wall > 50 cm (Turbidity)> 10 cm (TSS)
  • Weight
  • approx. 1.5 kg
  • What's included?
  • Turbidity & Suspended Solids sensor, user manual
LXV440.99.00002 AN-ISE sc Low cost ISE combination Ammonium and Nitrate probe (immersion) with RFID, 10 m cable 11091 
Add to Cart
  • Cable Length
  • 10 m (32.8 ft) fixed cable at sensor, available up to 100 m
  • Calibration Method
  • With Cartrical plus technology: automatic import of factory calibration data from cartridge to probe by RFID; 1 and 2 point matrix correction
  • Flow
  • < 4 m/s max. velocity
  • Length
  • 320 mm
  • Material
  • Cartridge: stainless steel (1.4571), PVC, POM, ABS, NBRCleaning unit: TPE, PUR, stainless steel (1.4571)Sensor: stainless steel (1.4571), ASA + PC, silicon, PVC and PU
  • Operating Temperature Range
  • Air: -20 - 45 °C (-4 - 113 °F)
  • Parameter
  • NH4-N and NO3-N
  • Protection Class
  • IP68
  • Range
  • 0 - 1000 mg/L NH4-N0 - 1000 mg/L NO3-N0 - 1000 mg/L K+0 - 1000 mg/L Cl-
  • Repeatability
  • ± 5 % of the measured value (with standard solution)+ 0.2 mg/L NH4-N and NO3-N
  • Storage Conditions
  • 5 to 40 °C (41 to 104 °F) sensor cartridge
  • Warranty
  • 12 months
  • Weight
  • 2.38 kg
  • What's included?
  • Ammonium & Nitrate probe, sensor cartridge, user manual
HACH9070800 USB Cable 28 
Add to Cart
HACH3422A1A Contacting Conductivity Sensor, Low Conductivity (k=0.05), with ½ 682 
Add to Cart
  • Cable Length
  • 6 m (20 ft)
  • Flow
  • 0 - 3 m/s maximum, fully immersed
  • Length
  • 193.5 mm
  • Material
  • Compression Fitting: 1/2" NPT PVDF
  • Operating Temperature Range
  • -20 - 200 °C
  • Pressure Range
  • 1.7 bar at 150 °C
  • Range
  • 0 - 100 µS/cm
  • Repeatability
  • ±0.5 % of reading
  • Response Time T90
  • 30 s
  • Warranty
  • 12 months
  • What's included?
  • Includes: sensor with 6 m (20 ft) cable and manual
HACH3433B8A General Purpose Contacting Conductivity Sensor, PPS Body, Low Conductivity (k=0.5) 564 
Add to Cart
  • Cable Length
  • 20 ft
  • Flow
  • 0 - 3 m/s
  • Length
  • 134.6 mm
  • Operating Temperature Range
  • -20 - 200 °C
  • Pressure Range
  • 6.8 bar at 150 °C (when used with hardware, a lower rated mounting hardware or piping material maylimit the temperatureand pressure ratings)
  • Range
  • 0 - 1000 µS/cm
  • Repeatability
  • ±0.5 % of reading
  • Response Time T90
  • < 30 s
  • Warranty
  • 12 months
  • What's included?
  • Includes: sensor with 6 m (20 ft) cable and manual
HACH3422B3A Contacting Conductivity Sensor for Low Conductivity, K=0.5, 3/4 682 
Add to Cart
  • Cable Length
  • 6 m (20 ft)
  • Flow
  • 0 - 3 m/s maximum, fully immersed
  • Length
  • 193.5 mm
  • Material
  • Compression Fitting: 3/4" NPT PVDF
  • Operating Temperature Range
  • -20 - 200 °C
  • Pressure Range
  • 1.7 bar at 150 °C
  • Range
  • 0 - 1000 µS/cm
  • Repeatability
  • ±0.5 % of reading
  • Response Time T90
  • 30 s
  • Warranty
  • 12 months
  • What's included?
  • Includes: sensor with 6 m cable and manual
HACH3422C3A Contacting Conductivity Sensor, Mid-Range Conductivity (k=1.0), with ¾ 682 
Add to Cart
  • Cable Length
  • 6 m (20 ft)
  • Flow
  • 0 - 3 m/s maximum, fully immersed
  • Length
  • 193.5 mm
  • Material
  • Compression Fitting: ¾" NPT PVDF
  • Operating Temperature Range
  • -20 - 200 °C
  • Pressure Range
  • 1.7 bar at 150 °C
  • Range
  • 0 - 2000 µS/cm
  • Repeatability
  • ±0.5 % of reading
  • Response Time T90
  • 30 s
  • Warranty
  • 12 months
  • What's included?
  • Includes: sensor with 6 m (20 ft) cable and manual