+852-3069 6950
sales@gugent.com.hk
 

Agilent Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is available in single quadrupole and triple quadrupole configurations. Our single quadrupole ICP-MS address the range of typical ICP-MS measurements from routine, regulated analysis to advanced research and demanding applications. Our triple quadrupole ICP-MS will give you the confidence of knowing you can resolve problematic interferences – even in your most difficult samples – delivering results you know you can trust.

Catalog No. Product Net Price
AGIL2010117500 Torch, low-flow, quartz, 1.4 mm id injector tube, for radial 700, Liberty and Vista Series ICP-OES. Annealed for greater strength. Recommended for routine analysis of organic solvents e.g. kerosene, xylene, white spirit 721 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Semi-volatile organics
  • Notes
  • Routine analysis of organic solvents, e.g. kerosene, xylene, and white spirit
  • Type
  • Semi-volatile organics
AGIL2010122400 Torch, sheath gas, high-solids with Agilent injector design, 2.4 mm id for axial 700, Liberty, and Vista series ICP-OES. Used with the AGM 1 auxiliary gas module, p/n G8473A for control of sheath gas flow, provides better performance than the high-solids 659 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous
  • Notes
  • Routine analysis of samples to 25 % TDS
  • Type
  • High TDS
AGIL7910050700 One piece quartz torch with ball joint for axial 700, Vista, and Liberty Series ICP-OES. Fitted with ball joint connection to torch and 2.3 mm id injector for use with MSIS. 799 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous
  • Type
  • Aqueous
G1833-65424 Quartz Torch, single-piece, 1.5 mm id tapered injector, for organic solvent analysis with Agilent 7500 ICP-MS. Suitable for organic applications, but not inert to samples containing hydrofluoric acid (HF) 602 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Organic solvents
  • Type
  • Organics
G3270-80043 Quartz Torch, single-piece, 2.5 mm id injector, standard for Agilent 7500 ICP-MS. Suitable for most routine applications, but not for volatile organic solvents or samples containing hydrofluoric acid (HF) 605 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous
  • Type
  • Aqueous
G3280-80053 Quartz Torch, single-piece, 2.5 mm id injector, standard for Agilent 7700, 7800, 7850, 7900, 8800, 8900 ICP-MS. Suitable for most routine applications, but not for volatile organic solvents or samples containing hydrofluoric acid (HF) 421 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous
  • Notes
  • Standard torch for most applicationsNot suitable for samples containing hydrofluoric acid Not suitable for samples containing hydrofluoric acid -->
  • Type
  • Aqueous
G3280-80080 Quartz Torch, single-piece, 1.5 mm id tapered injector, for organic solvent analysis with Agilent 7700, 7800, 7850, 7900, 8800, 8900 ICP-MS. Suitable for organic applications, but not inert to samples containing hydrofluoric acid (HF) 897 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Organic solvents
  • Notes
  • For use with organic solvents.Not suitable for samples containing hydrofluoric acid Not suitable for samples containing hydrofluoric acid -->
  • Type
  • Organics
G4912-80012 Semi-demountable inert torch for PFA inert kit, used with 2.5mm id sapphire or platinum injector for aqeous applications. Replacement outer quartz torch body for PFA inert sample introduction kit suitable for Agilent 7500, 7700, 7800, 7850, 7900, 8800, 89 1267 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous HF acid Strong acids
  • Type
  • Inert
G8003-60018 Easy-fit inert torch, for Agilent 4200 MP-AES, for use with HF digests. Not compatible with the earlier model 4100-MP-AES. Supplied with an inert alumina injector, PTFE ball joint coupler and inert torch clamp. Recommended for use with the inert double pa 1604 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Chemical Compatibility
  • Aqueous HF acid
  • Type
  • Inert
G8003-70000 Torch, easy-fit, for Agilent 4200 MP-AES only (not compatible with earlier model 4100-MP-AES), blue base for easy identification. Features a 1.2mm ID injector with a ball joint base for easy connection to the spray chamber (the standard torch) 761 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Chemical Compatibility
  • Aqueous Aromatic organics Ketone solvents
  • Type
  • Aqueous

Overview

ICP-MS system operates with an ICP-MS Nebulizer, in which a high velocity Argon gas stream meets a liquid stream causing filmwise breakup of the solution into a fine aerosol. The aerosol particle size should ideally be sub-10µm with a narrow particle size distribution to achieve efficient atomization and ionization. Agilent offers a comprehensive range of ICP-MS nebulizers and supplies to solve any ICP-MS analysis challenge.

The portfolio includes standard glass concentric nebulizer (MicroMist), quartz and inert PFA nebulizers (MicroFlow and C-Flow), as well as robust Mira Mist PEEK or PTFE for high TDS samples and low-flow self-aspirating or total consumption nebulizers for your clinical or limited volume samples. ICP-MS nebulizer support is provided with a full range of accessories for all models including nebulizer cleaning tools.


The ICP torch is used to form, shape, and sustain an argon plasma which atomizes and ionizes the sample aerosol. Agilent ICP-MS Torches with Shield Torch System (STS) provide precise ion energy control, ensuring high sensitivity and stability, even in cool plasma mode for effective interference removal (ArO+).

Our portfolio is comprised of a wide range of ICP torches for your specific ICP-MS configuration. One-piece quartz torches offer the best stability and ease of use. The large 2.5mm injector on the standard torch gives maximum robustness and lowest matrix interferences for the best plasma stability. Single-piece torches with narrow bore injectors (1.0mm or 1.5 mm) are designed for use with organic solvents, to reduce plasma loading and improve plasma stability. Optional semi-demountable quartz torches with removable platinum or sapphire injectors are also available for use with the PFA inert sample introduction kit.


Resources