+852-3069 6950
sales@gugent.com.hk
 

Agilent Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is available in single quadrupole and triple quadrupole configurations. Our single quadrupole ICP-MS address the range of typical ICP-MS measurements from routine, regulated analysis to advanced research and demanding applications. Our triple quadrupole ICP-MS will give you the confidence of knowing you can resolve problematic interferences – even in your most difficult samples – delivering results you know you can trust.

Catalog No. Product Net Price
G8007-68001 Spray chamber, MP-AES, twister style (double-pass) cyclonic, encapsulated, for use with IsoMist with LOL configuration 1230 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Chemical Compatibility
  • Aqueous Aromatic organics Ketone solvents
  • Material
  • Borosilicate Glass
  • Notes
  • Twister style (double pass) glass cyclonic with thermal conductive polymer encapsulation for use with IsoMist for MP-AES (LoL configuration)Will not fit the IsoMist for the 5100/5110 ICP-OES. Will not fit the IsoMist for the 5100/5110 ICP-OES. -->
  • Type
  • Double pass
AGIL5042-1385 Obsolete. Replaced by 5043-9311. 96 well plates, 0.5 mL, polypropylene 120/pk 271 
Add to Cart
  • UNSPSC Code
  • 41115714
AGIL5042-1386 Obsolete. Replaced by 5043-9310. 96 well plates, 0.5 mL, polypropylene 10/pk 27 
Add to Cart
  • UNSPSC Code
  • 41115714
G3270-65035 ORS cell gas tubing, stainless steel, 1/8 in od, 6 m. For supply connection of Helium, Hydrogen or reaction gas from regulator to instrument. Recommended to purchase tubing cutter 8710-1709 for installation. 241 
Add to Cart
  • Length
  • 6 m
  • UNSPSC Code
  • 41115411
  • Tubing Material
  • Stainless steel
  • Tubing OD
  • 0.125 in
  • Where Used
  • ORS cell gas
G3280-60163 Tubing and filter for Argon supply to instrument, for Agilent ICP-MS with s-lens for semiconductor analysis. Includes PTFE tubing (5 m) with fittings and connector (p/n 5063-9132), high purity Argon Gas filter (p/n 5064-8092). Suitable for 7700, 7900, 880 997 
Add to Cart
  • Length
  • 5 m
  • UNSPSC Code
  • 41115411
  • Tubing Material
  • PTFE
  • Where Used
  • Argon gas
G3280-67022 Tubing for external carrier, makeup and dilution gas, 1pc tubing for each. Suitable for 7700, 7800, 7850, 7900, 8800, 8900 ICP-MS. Used to connect nebulizer, make-up and HMI/UHMI aerosol dilution Argon gas from instrument to sample introduction component 94 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Where Used
  • Argon gas
G3666-67026 Argon gas supply tubing set for Argon gas purifier, Big Universal Trap, for use with 8900 ICP-MS. Only used on 8900 ICP-MS 736 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Where Used
  • Argon gas
AGIL8003-0536 PerkinElmer ICP-MS Support adapter, for twist-type ball-joint injector, for ELAN DRC/DRCplus/DRC II 203 
Add to Cart
  • UNSPSC Code
  • 41122000
AGIL8003-0537 PerkinElmer ICP-MS Support adapter, for cassette-type ball joint injector, for ELAN DRC II 323 
Add to Cart
  • UNSPSC Code
  • 41122000
AGIL8003-0545 PerkinElmer ICP-MS Injector support adapter, twist-type, for ELAN DRC-e/9000/6x00/5000. For corrosion-resistant torch and Ryton Scott spray chamber and twist-type torch mounts before April 2005 72 
Add to Cart
  • UNSPSC Code
  • 41122000

Overview

ICP-MS system operates with an ICP-MS Nebulizer, in which a high velocity Argon gas stream meets a liquid stream causing filmwise breakup of the solution into a fine aerosol. The aerosol particle size should ideally be sub-10µm with a narrow particle size distribution to achieve efficient atomization and ionization. Agilent offers a comprehensive range of ICP-MS nebulizers and supplies to solve any ICP-MS analysis challenge.

The portfolio includes standard glass concentric nebulizer (MicroMist), quartz and inert PFA nebulizers (MicroFlow and C-Flow), as well as robust Mira Mist PEEK or PTFE for high TDS samples and low-flow self-aspirating or total consumption nebulizers for your clinical or limited volume samples. ICP-MS nebulizer support is provided with a full range of accessories for all models including nebulizer cleaning tools.


The ICP torch is used to form, shape, and sustain an argon plasma which atomizes and ionizes the sample aerosol. Agilent ICP-MS Torches with Shield Torch System (STS) provide precise ion energy control, ensuring high sensitivity and stability, even in cool plasma mode for effective interference removal (ArO+).

Our portfolio is comprised of a wide range of ICP torches for your specific ICP-MS configuration. One-piece quartz torches offer the best stability and ease of use. The large 2.5mm injector on the standard torch gives maximum robustness and lowest matrix interferences for the best plasma stability. Single-piece torches with narrow bore injectors (1.0mm or 1.5 mm) are designed for use with organic solvents, to reduce plasma loading and improve plasma stability. Optional semi-demountable quartz torches with removable platinum or sapphire injectors are also available for use with the PFA inert sample introduction kit.


Resources