+852-3069 6950
sales@gugent.com.hk
 

Agilent Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is available in single quadrupole and triple quadrupole configurations. Our single quadrupole ICP-MS address the range of typical ICP-MS measurements from routine, regulated analysis to advanced research and demanding applications. Our triple quadrupole ICP-MS will give you the confidence of knowing you can resolve problematic interferences – even in your most difficult samples – delivering results you know you can trust.

Catalog No. Product Net Price
G1833-66011 Alignment plate for RF work coil, for all Agilent ICP-MS 152 
Add to Cart
  • UNSPSC Code
  • 41115411
G8400-60434 RF work coil assembly, for Agilent 7800, 7850, 7900 and 8900 ICP-MS 528 
Add to Cart
  • UNSPSC Code
  • 41113000
G8012-60000 Easy-fit torch, one piece, with 1.4 mm id injector, for 5000 series RV (radial) ICP-OES. Features a 1.4mm ID injector with a shorter outer tube (no slit) for dedicated radial viewing. This is the standard torch for the radial instrument. 762 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Chemical Compatibility
  • Aqueous Semi-volatile organics
  • Type
  • Aqueous Semi-volatile organics
G8020-68004 Fully demountable Easy-fit torch with 2.4mm ID quartz injector for high TDS samples. Includes Qty 2x replaceable DV outer tube-sets with slot for radial viewing. This torch with the 2.4mm ID tapered quartz injector is recommended for analysis of high tota 1611 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Chemical Compatibility
  • Aqueous
  • Type
  • High TDS
G8020-68007 Easy-fit fully demountable RV torch, with 1.4 mm id tapered quartz injector for semivolatile organics. Includes a replaceable shorter (high purity quartz) outer tube for organic applications for dedicated radial (no slot) viewing. This torch with the 1.4 1611 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Chemical Compatibility
  • Aqueous Semi-volatile organics
  • Type
  • Semi-volatile organics
AGIL2010069690 Torch, low-flow, quartz, 1.4 mm id injector tube, for radial 700, Liberty and Vista Series ICP-OES. Recommended for routine analysis of aqueous samples <10% TDS. 503 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous
  • Notes
  • Routine analysis of aqueous samples
  • Type
  • Aqueous
AGIL2010095000 Torch, high-solids, Agilent injector design, 1.8 mm id for radial 700, Liberty and Vista Series ICP-OES. Recommended for routine analysis of samples up to 25% TDS. 558 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous
  • Notes
  • Routine analysis of samples to 25 % TDS
  • Type
  • High TDS
AGIL2010104700 Torch, low-flow, quartz, 0.8 mm id injector tube, for axial 700, Liberty, and Vista series ICP-OES. Recommended for routine analysis of volatile organic solvents e.g. gasoline 618 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Volatile organics
  • Notes
  • Routine analysis of volatile organic solvents, e.g. gasoline
  • Type
  • Volatile organics
AGIL2010104800 Torch, low-flow, quartz, 1.4 mm id injector tube, for axial 700, Liberty, and Vista series ICP-OES. Recommended for routine analysis of organic solvents e.g. kerosene, xylene, white spirit 616 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Semi-volatile organics
  • Notes
  • Routine analysis of organic solvents, e.g. kerosene, xylene, and white spirit
  • Type
  • Semi-volatile organics
AGIL2010117400 Torch, low-flow, quartz, 0.8 mm id injector tube, for radial 700, Liberty and Vista Series ICP-OES. Annealed for greater strength. Recommended for routine analysis of volatile organic solvents e.g. gasoline 630 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Volatile organics
  • Notes
  • Routine analysis of volatile organic solvents, e.g. gasoline
  • Type
  • Volatile organics

Overview

ICP-MS system operates with an ICP-MS Nebulizer, in which a high velocity Argon gas stream meets a liquid stream causing filmwise breakup of the solution into a fine aerosol. The aerosol particle size should ideally be sub-10µm with a narrow particle size distribution to achieve efficient atomization and ionization. Agilent offers a comprehensive range of ICP-MS nebulizers and supplies to solve any ICP-MS analysis challenge.

The portfolio includes standard glass concentric nebulizer (MicroMist), quartz and inert PFA nebulizers (MicroFlow and C-Flow), as well as robust Mira Mist PEEK or PTFE for high TDS samples and low-flow self-aspirating or total consumption nebulizers for your clinical or limited volume samples. ICP-MS nebulizer support is provided with a full range of accessories for all models including nebulizer cleaning tools.


The ICP torch is used to form, shape, and sustain an argon plasma which atomizes and ionizes the sample aerosol. Agilent ICP-MS Torches with Shield Torch System (STS) provide precise ion energy control, ensuring high sensitivity and stability, even in cool plasma mode for effective interference removal (ArO+).

Our portfolio is comprised of a wide range of ICP torches for your specific ICP-MS configuration. One-piece quartz torches offer the best stability and ease of use. The large 2.5mm injector on the standard torch gives maximum robustness and lowest matrix interferences for the best plasma stability. Single-piece torches with narrow bore injectors (1.0mm or 1.5 mm) are designed for use with organic solvents, to reduce plasma loading and improve plasma stability. Optional semi-demountable quartz torches with removable platinum or sapphire injectors are also available for use with the PFA inert sample introduction kit.


Resources