+852-3069 6950
sales@gugent.com.hk
 

With industry-leading sterile filtration devices based on 60 years of membrane filtration expertise, MilliporeSigma supports conventional and emerging formats for cell culture. The MilliporeSigma Cell Culture Solutions portfolio features over 20,000 high-quality tools to cultivate consistency in your cell culture workflow.

Cell Preparation: Tools that you need to minimize contamination risk and maximize workflow efficiency while preparing your media for cell culture.

Cell Growth: Whatever your cell culture growth needs, we have a plate, insert or vessel that can help you obtain the optimal cell culture results.

Cell Analysis: In addition to our solid base in assay tools and products, we offer new, novel cell culture technologies and cell culture platforms for high content data collection and analysis.

Catalog No. Product Net Price
MAFCN0B50 Multiscreen GFC Filter Plate, Opaque Non-sterile 1002 
Add to Cart
  • Automation Compatible
  • No
  • Background Information
  • Glass Fiber Filter Membrane Filters:Glass fiber filters with binder resin have superior wet strength and are excellent for qualitative analysis and prefiltration, especially for heavily contaminated or particular laden samples. They are also widely used for clarification of aqueous solutions.Glass fiber filters with binder resin have superior wet strength and are excellent for qualitative analysis and prefiltration, especially for heavily contaminated or particulate-laden samples. They are also widely used for clarification of aqueous solutions.Features & Benefits: - Multiple configurations and applications - Chemical compatibility - Automation-compatible - Superior vacuum filtration and filtrate collection Applications: - Receptor/Ligand Binding Assays, Sample Preparation, TCA Precipitation of Protein
  • Catalogue Number
  • MAFCN0B50
  • Chemistry
  • Glass FiberHydrophilic Polyvinylidene Fluoride (PVDF)
  • Color Code
  • Opaque
  • Device Material
  • Barex®/TiO2
  • Filter Code
  • FC
  • Filtration Area
  • 0.26 cm²
  • Height
  • 14.4 mm
  • Key Applications
  • Receptor/Ligand Binding AssaysSample PrepTCA Precipitation
  • Length
  • 128 mm
  • Material Size
  • 50
  • Number of Wells
  • 96
  • Sterility
  • Non-Sterile
  • Trade Name
  • MultiScreen
  • Volume
  • 50 µL–250 µL
  • Width
  • 85.5 mm
MAFCN0B50 Multiscreen GFC Filter Plate, Opaque Non-sterile 1002 
Add to Cart
  • Automation Compatible
  • No
  • Background Information
  • Glass Fiber Filter Membrane Filters:Glass fiber filters with binder resin have superior wet strength and are excellent for qualitative analysis and prefiltration, especially for heavily contaminated or particular laden samples. They are also widely used for clarification of aqueous solutions.Glass fiber filters with binder resin have superior wet strength and are excellent for qualitative analysis and prefiltration, especially for heavily contaminated or particulate-laden samples. They are also widely used for clarification of aqueous solutions.Features & Benefits: - Multiple configurations and applications - Chemical compatibility - Automation-compatible - Superior vacuum filtration and filtrate collection Applications: - Receptor/Ligand Binding Assays, Sample Preparation, TCA Precipitation of Protein
  • Catalogue Number
  • MAFCN0B50
  • Chemistry
  • Glass FiberHydrophilic Polyvinylidene Fluoride (PVDF)
  • Color Code
  • Opaque
  • Device Material
  • Barex®/TiO2
  • Filter Code
  • FC
  • Filtration Area
  • 0.26 cm²
  • Height
  • 14.4 mm
  • Key Applications
  • Receptor/Ligand Binding AssaysSample PrepTCA Precipitation
  • Length
  • 128 mm
  • Material Size
  • 50
  • Number of Wells
  • 96
  • Sterility
  • Non-Sterile
  • Trade Name
  • MultiScreen
  • Volume
  • 50 µL–250 µL
  • Width
  • 85.5 mm
MSFCNXB50 MultiScreenHTS+ FC Filter Plate, Hi Flow, opaque, non-sterile 1044 
Add to Cart
  • Automation Compatible
  • Yes
  • Background Information
  • No matter what application you’re working with, Millipore has a plate developed to meet your specific needs. MultiScreen plates have a long history as a reliable tool for the advancement of drug discovery and life science research. HTS Filter Plates (Plate catalogue numbers that start with MS) - MultiScreenHTS plates are specifically developed for high-throughput use with automated work stations. Rigid sidewalls improve handling and ample surfaces are provided for bar code labels. Wells are individually sealed to prevent incubation crosstalk and the underdrain is removable for access to the filters. Filter plates are available in 96- and 384-well platforms with a broad selection of membranes and plastics. - Millipore’s new MultiScreen HTS+ Hi flow filter plate design lessens non-specific binding and reduces variability in both background and signal intensities specifically for biochemical screening assays.Classic Filter Plates (Plate catalogue numbers that start with MA) - The original multiwell design is valuable for many applications which require immersing the filter in an assay tray. The easily removable underdrain and unique plate design are ideal for assays such as Elispot, PAMPA, cell screening (migration, invasion or chemotaxis) or for topcount detection users.Accessory – MultiScreenHTS Vacuum Manifold - The MultiScreenHTS Vacuum manifold was designed specifically to work with MultiScreenHTS filter plates. The combination results in optimal filtration characteristics and seamless automation integration.Millicell Assay Plates - In addition to the traditional assay plate format, filter plates are also available with cell culture trays for growing and assaying suspension and adherent cell lines. Cells grown on filter plates differentiate better than those grown on traditional plastic substrates, resulting in more in vivo-like results This filter plate/tray combination can be used for a variety of cellular assays, including, transport, toxicity and screening assays.
  • Catalogue Number
  • MSFCNXB50
  • Chemistry
  • Glass FiberPolyester Mesh
  • Color Code
  • Opaque
  • Device Material
  • Barex®/TiO2
  • Filter Code
  • FC
  • Filtration Area
  • 0.26 cm²
  • Height
  • 14.4 mm
  • Key Applications
  • Receptor/Ligand Binding AssaysSample PrepTCA Precipitation
  • Length
  • 128 mm
  • Material Size
  • 50
  • Number of Wells
  • 96
  • Pore Size
  • 1.2 / 0.65 µm
  • Sterility
  • Non-Sterile
  • Trade Name
  • MultiScreen
  • Volume
  • 50 µL–250 µL
  • Width
  • 85.5 mm
MSFCNXB50 MultiScreenHTS+ FC Filter Plate, Hi Flow, opaque, non-sterile 1044 
Add to Cart
  • Automation Compatible
  • Yes
  • Background Information
  • No matter what application you’re working with, Millipore has a plate developed to meet your specific needs. MultiScreen plates have a long history as a reliable tool for the advancement of drug discovery and life science research. HTS Filter Plates (Plate catalogue numbers that start with MS) - MultiScreenHTS plates are specifically developed for high-throughput use with automated work stations. Rigid sidewalls improve handling and ample surfaces are provided for bar code labels. Wells are individually sealed to prevent incubation crosstalk and the underdrain is removable for access to the filters. Filter plates are available in 96- and 384-well platforms with a broad selection of membranes and plastics. - Millipore’s new MultiScreen HTS+ Hi flow filter plate design lessens non-specific binding and reduces variability in both background and signal intensities specifically for biochemical screening assays.Classic Filter Plates (Plate catalogue numbers that start with MA) - The original multiwell design is valuable for many applications which require immersing the filter in an assay tray. The easily removable underdrain and unique plate design are ideal for assays such as Elispot, PAMPA, cell screening (migration, invasion or chemotaxis) or for topcount detection users.Accessory – MultiScreenHTS Vacuum Manifold - The MultiScreenHTS Vacuum manifold was designed specifically to work with MultiScreenHTS filter plates. The combination results in optimal filtration characteristics and seamless automation integration.Millicell Assay Plates - In addition to the traditional assay plate format, filter plates are also available with cell culture trays for growing and assaying suspension and adherent cell lines. Cells grown on filter plates differentiate better than those grown on traditional plastic substrates, resulting in more in vivo-like results This filter plate/tray combination can be used for a variety of cellular assays, including, transport, toxicity and screening assays.
  • Catalogue Number
  • MSFCNXB50
  • Chemistry
  • Glass FiberPolyester Mesh
  • Color Code
  • Opaque
  • Device Material
  • Barex®/TiO2
  • Filter Code
  • FC
  • Filtration Area
  • 0.26 cm²
  • Height
  • 14.4 mm
  • Key Applications
  • Receptor/Ligand Binding AssaysSample PrepTCA Precipitation
  • Length
  • 128 mm
  • Material Size
  • 50
  • Number of Wells
  • 96
  • Pore Size
  • 1.2 / 0.65 µm
  • Sterility
  • Non-Sterile
  • Trade Name
  • MultiScreen
  • Volume
  • 50 µL–250 µL
  • Width
  • 85.5 mm
MSVMHTS09 Replacement Tubing, 10 ft (3 m) 50 
Add to Cart
  • Background Information
  • MultiScreen vacuum manifolds have been developed for all vacuum filtration applications using MultiScreenHTS and MultiScreen filter plates. Manifold components are resistant to solvents and suitable for use with automated or manual protocols.New MultiScreenHTS Vacuum Manifold with DirectStack™ technologyThe new MultiScreenHTS vacuum manifold provides enhanced performance for use with MultiScreenHTS 96- and 384-well filter plates as well as the Solvinert family of filter plates. It can be easily configured for both flow-to-waste and analyte collection. For applications that require filtrate collection for further analysis, the MultiScreenHTS vacuum manifold and filter plates offer a significant improvement in reliability over current systems. When used with MultiScreenHTS filter plates and ANSI/SBS standard receiver plates, the unique plate and manifold designs combine to eliminate gaps between the flow directors and receiver wells and provide a plate-on-plate processing option for assays where filtrate collection is required. Direct stacking also makes vacuum initiations effortless. Complete filtration assay cycles can be done with no manual intervention. The MultiScreenHTS vacuum manifold features: - DirectStack™ technology for crosstalk-free filtrate collection - Configurations for deep well or standard receiver plates - ANSI/SBS compliant footprint allows for easy robotic deck integration Also available: MultiScreen Vacuum Manifold for classic filter plates.Chemical Compatibility - The compatibility list, which you can find on General Guidelines for MultiScreen Plates covers chemicals which are compatible with the MultiScreenHTS and MultiScreen vacuum manifolds, as well as MultiScreen Solvinert filter plates.Applications -Vacuum Filtration of Multiwell Filter Plates, Automated Liquid Handling
  • Catalogue Number
  • MSVMHTS09
  • Material Size
  • 1
  • Trade Name
  • MultiScreen
MSVMHTS09 Replacement Tubing, 10 ft (3 m) 50 
Add to Cart
  • Background Information
  • MultiScreen vacuum manifolds have been developed for all vacuum filtration applications using MultiScreenHTS and MultiScreen filter plates. Manifold components are resistant to solvents and suitable for use with automated or manual protocols.New MultiScreenHTS Vacuum Manifold with DirectStack™ technologyThe new MultiScreenHTS vacuum manifold provides enhanced performance for use with MultiScreenHTS 96- and 384-well filter plates as well as the Solvinert family of filter plates. It can be easily configured for both flow-to-waste and analyte collection. For applications that require filtrate collection for further analysis, the MultiScreenHTS vacuum manifold and filter plates offer a significant improvement in reliability over current systems. When used with MultiScreenHTS filter plates and ANSI/SBS standard receiver plates, the unique plate and manifold designs combine to eliminate gaps between the flow directors and receiver wells and provide a plate-on-plate processing option for assays where filtrate collection is required. Direct stacking also makes vacuum initiations effortless. Complete filtration assay cycles can be done with no manual intervention. The MultiScreenHTS vacuum manifold features: - DirectStack™ technology for crosstalk-free filtrate collection - Configurations for deep well or standard receiver plates - ANSI/SBS compliant footprint allows for easy robotic deck integration Also available: MultiScreen Vacuum Manifold for classic filter plates.Chemical Compatibility - The compatibility list, which you can find on General Guidelines for MultiScreen Plates covers chemicals which are compatible with the MultiScreenHTS and MultiScreen vacuum manifolds, as well as MultiScreen Solvinert filter plates.Applications -Vacuum Filtration of Multiwell Filter Plates, Automated Liquid Handling
  • Catalogue Number
  • MSVMHTS09
  • Material Size
  • 1
  • Trade Name
  • MultiScreen
MACL0SC03 Scraper for MultiScreen Column Loader 96 
Add to Cart
  • Background Information
  • No matter what application you’re working with, Millipore has a plate developed to meet your specific needs. MultiScreen plates have a long history as a reliable tool for the advancement of drug discovery and life science research. HTS Filter Plates - MultiScreenHTS plates are specifically developed for high-throughput use with automated work stations. Rigid sidewalls improve handling and ample surfaces are provided for bar code labels. Wells are individually sealed to prevent incubation crosstalk and the underdrain is removable for access to the filters. Filter plates are available in 96- and 384-well platforms with a broad selection of membranes and plastics. - Millipore’s new MultiScreen HTS+ Hi flow filter plate design lessens non-specific binding and reduces variability in both background and signal intensities specifically for biochemical screening assays.Classic Filter Plates - The original multiwell design is valuable for many applications which require immersing the filter in an assay tray. The easily removable underdrain and unique plate design are ideal for assays such as Elispot, PAMPA, cell screening (migration, invasion or chemotaxis) or for topcount detection users.Accessory – MultiScreenHTS Vacuum Manifold - The MultiScreenHTS Vacuum manifold was designed specifically to work with MultiScreenHTS filter plates. The combination results in optimal filtration characteristics and seamless automation integration.Millicell Assay Plates - In addition to the traditional assay plate format, filter plates are also available with cell culture trays for growing and assaying suspension and adherent cell lines. Cells grown on filter plates differentiate better than those grown on traditional plastic substrates, resulting in more in vivo-like results This filter plate/tray combination can be used for a variety of cellular assays, including, transport, toxicity and screening assays.
  • Catalogue Number
  • MACL0SC03
  • Color Code
  • Clear
  • Device Material
  • Acrylic
  • Material Size
  • 3
  • Trade Name
  • MultiScreen
MACL0SC03 Scraper for MultiScreen Column Loader 96 
Add to Cart
  • Background Information
  • No matter what application you’re working with, Millipore has a plate developed to meet your specific needs. MultiScreen plates have a long history as a reliable tool for the advancement of drug discovery and life science research. HTS Filter Plates - MultiScreenHTS plates are specifically developed for high-throughput use with automated work stations. Rigid sidewalls improve handling and ample surfaces are provided for bar code labels. Wells are individually sealed to prevent incubation crosstalk and the underdrain is removable for access to the filters. Filter plates are available in 96- and 384-well platforms with a broad selection of membranes and plastics. - Millipore’s new MultiScreen HTS+ Hi flow filter plate design lessens non-specific binding and reduces variability in both background and signal intensities specifically for biochemical screening assays.Classic Filter Plates - The original multiwell design is valuable for many applications which require immersing the filter in an assay tray. The easily removable underdrain and unique plate design are ideal for assays such as Elispot, PAMPA, cell screening (migration, invasion or chemotaxis) or for topcount detection users.Accessory – MultiScreenHTS Vacuum Manifold - The MultiScreenHTS Vacuum manifold was designed specifically to work with MultiScreenHTS filter plates. The combination results in optimal filtration characteristics and seamless automation integration.Millicell Assay Plates - In addition to the traditional assay plate format, filter plates are also available with cell culture trays for growing and assaying suspension and adherent cell lines. Cells grown on filter plates differentiate better than those grown on traditional plastic substrates, resulting in more in vivo-like results This filter plate/tray combination can be used for a variety of cellular assays, including, transport, toxicity and screening assays.
  • Catalogue Number
  • MACL0SC03
  • Color Code
  • Clear
  • Device Material
  • Acrylic
  • Material Size
  • 3
  • Trade Name
  • MultiScreen
LSKS09601 Montage SEQ96 Sequencing Reaction Cleanup Kit 113 
Add to Cart
  • Automation Compatible
  • No
  • Catalogue Number
  • LSKS09601
  • Color Code
  • Blue
  • Components
  • includes 96-well filter plates and injection solution
  • Key Applications
  • DNA Sequencing
  • Material Size
  • 1
  • Number of Wells
  • 96
  • Sterility
  • Non-Sterile
  • Trade Name
  • Montage
LSKS09601 Montage SEQ96 Sequencing Reaction Cleanup Kit 113 
Add to Cart
  • Automation Compatible
  • No
  • Catalogue Number
  • LSKS09601
  • Color Code
  • Blue
  • Components
  • includes 96-well filter plates and injection solution
  • Key Applications
  • DNA Sequencing
  • Material Size
  • 1
  • Number of Wells
  • 96
  • Sterility
  • Non-Sterile
  • Trade Name
  • Montage