+852-3069 6950
sales@gugent.com.hk
 

With industry-leading sterile filtration devices based on 60 years of membrane filtration expertise, MilliporeSigma supports conventional and emerging formats for cell culture. The MilliporeSigma Cell Culture Solutions portfolio features over 20,000 high-quality tools to cultivate consistency in your cell culture workflow.

Cell Preparation: Tools that you need to minimize contamination risk and maximize workflow efficiency while preparing your media for cell culture.

Cell Growth: Whatever your cell culture growth needs, we have a plate, insert or vessel that can help you obtain the optimal cell culture results.

Cell Analysis: In addition to our solid base in assay tools and products, we offer new, novel cell culture technologies and cell culture platforms for high content data collection and analysis.

Catalog No. Product Net Price
MSVMHTS10 Control Valve Kit 167 
Add to Cart
  • Background Information
  • MultiScreen vacuum manifolds have been developed for all vacuum filtration applications using MultiScreenHTS and MultiScreen filter plates. Manifold components are resistant to solvents and suitable for use with automated or manual protocols.New MultiScreenHTS Vacuum Manifold with DirectStack™ technologyThe new MultiScreenHTS vacuum manifold provides enhanced performance for use with MultiScreenHTS 96- and 384-well filter plates as well as the Solvinert family of filter plates. It can be easily configured for both flow-to-waste and analyte collection. For applications that require filtrate collection for further analysis, the MultiScreenHTS vacuum manifold and filter plates offer a significant improvement in reliability over current systems. When used with MultiScreenHTS filter plates and ANSI/SBS standard receiver plates, the unique plate and manifold designs combine to eliminate gaps between the flow directors and receiver wells and provide a plate-on-plate processing option for assays where filtrate collection is required. Direct stacking also makes vacuum initiations effortless. Complete filtration assay cycles can be done with no manual intervention. The MultiScreenHTS vacuum manifold features: - DirectStack™ technology for crosstalk-free filtrate collection - Configurations for deep well or standard receiver plates - ANSI/SBS compliant footprint allows for easy robotic deck integration Also available: MultiScreen Vacuum Manifold for classic filter plates.Chemical Compatibility - The compatibility list, which you can find on General Guidelines for MultiScreen Plates covers chemicals which are compatible with the MultiScreenHTS and MultiScreen vacuum manifolds, as well as MultiScreen Solvinert filter plates.Applications -Vacuum Filtration of Multiwell Filter Plates, Automated Liquid Handling
  • Catalogue Number
  • MSVMHTS10
  • Material Size
  • 1
  • Trade Name
  • MultiScreen
MSVMHTS10 Control Valve Kit 167 
Add to Cart
  • Background Information
  • MultiScreen vacuum manifolds have been developed for all vacuum filtration applications using MultiScreenHTS and MultiScreen filter plates. Manifold components are resistant to solvents and suitable for use with automated or manual protocols.New MultiScreenHTS Vacuum Manifold with DirectStack™ technologyThe new MultiScreenHTS vacuum manifold provides enhanced performance for use with MultiScreenHTS 96- and 384-well filter plates as well as the Solvinert family of filter plates. It can be easily configured for both flow-to-waste and analyte collection. For applications that require filtrate collection for further analysis, the MultiScreenHTS vacuum manifold and filter plates offer a significant improvement in reliability over current systems. When used with MultiScreenHTS filter plates and ANSI/SBS standard receiver plates, the unique plate and manifold designs combine to eliminate gaps between the flow directors and receiver wells and provide a plate-on-plate processing option for assays where filtrate collection is required. Direct stacking also makes vacuum initiations effortless. Complete filtration assay cycles can be done with no manual intervention. The MultiScreenHTS vacuum manifold features: - DirectStack™ technology for crosstalk-free filtrate collection - Configurations for deep well or standard receiver plates - ANSI/SBS compliant footprint allows for easy robotic deck integration Also available: MultiScreen Vacuum Manifold for classic filter plates.Chemical Compatibility - The compatibility list, which you can find on General Guidelines for MultiScreen Plates covers chemicals which are compatible with the MultiScreenHTS and MultiScreen vacuum manifolds, as well as MultiScreen Solvinert filter plates.Applications -Vacuum Filtration of Multiwell Filter Plates, Automated Liquid Handling
  • Catalogue Number
  • MSVMHTS10
  • Material Size
  • 1
  • Trade Name
  • MultiScreen
MSVMHTS06 On/Off Valve Kit 172 
Add to Cart
  • Background Information
  • MultiScreen vacuum manifolds have been developed for all vacuum filtration applications using MultiScreenHTS and MultiScreen filter plates. Manifold components are resistant to solvents and suitable for use with automated or manual protocols.New MultiScreenHTS Vacuum Manifold with DirectStack™ technologyThe new MultiScreenHTS vacuum manifold provides enhanced performance for use with MultiScreenHTS 96- and 384-well filter plates as well as the Solvinert family of filter plates. It can be easily configured for both flow-to-waste and analyte collection. For applications that require filtrate collection for further analysis, the MultiScreenHTS vacuum manifold and filter plates offer a significant improvement in reliability over current systems. When used with MultiScreenHTS filter plates and ANSI/SBS standard receiver plates, the unique plate and manifold designs combine to eliminate gaps between the flow directors and receiver wells and provide a plate-on-plate processing option for assays where filtrate collection is required. Direct stacking also makes vacuum initiations effortless. Complete filtration assay cycles can be done with no manual intervention. The MultiScreenHTS vacuum manifold features: - DirectStack™ technology for crosstalk-free filtrate collection - Configurations for deep well or standard receiver plates - ANSI/SBS compliant footprint allows for easy robotic deck integration Also available: MultiScreen Vacuum Manifold for classic filter plates.Chemical Compatibility - The compatibility list, which you can find on General Guidelines for MultiScreen Plates covers chemicals which are compatible with the MultiScreenHTS and MultiScreen vacuum manifolds, as well as MultiScreen Solvinert filter plates.Applications -Vacuum Filtration of Multiwell Filter Plates, Automated Liquid Handling
  • Catalogue Number
  • MSVMHTS06
  • Material Size
  • 1
  • Trade Name
  • MultiScreen
MSVMHTS06 On/Off Valve Kit 172 
Add to Cart
  • Background Information
  • MultiScreen vacuum manifolds have been developed for all vacuum filtration applications using MultiScreenHTS and MultiScreen filter plates. Manifold components are resistant to solvents and suitable for use with automated or manual protocols.New MultiScreenHTS Vacuum Manifold with DirectStack™ technologyThe new MultiScreenHTS vacuum manifold provides enhanced performance for use with MultiScreenHTS 96- and 384-well filter plates as well as the Solvinert family of filter plates. It can be easily configured for both flow-to-waste and analyte collection. For applications that require filtrate collection for further analysis, the MultiScreenHTS vacuum manifold and filter plates offer a significant improvement in reliability over current systems. When used with MultiScreenHTS filter plates and ANSI/SBS standard receiver plates, the unique plate and manifold designs combine to eliminate gaps between the flow directors and receiver wells and provide a plate-on-plate processing option for assays where filtrate collection is required. Direct stacking also makes vacuum initiations effortless. Complete filtration assay cycles can be done with no manual intervention. The MultiScreenHTS vacuum manifold features: - DirectStack™ technology for crosstalk-free filtrate collection - Configurations for deep well or standard receiver plates - ANSI/SBS compliant footprint allows for easy robotic deck integration Also available: MultiScreen Vacuum Manifold for classic filter plates.Chemical Compatibility - The compatibility list, which you can find on General Guidelines for MultiScreen Plates covers chemicals which are compatible with the MultiScreenHTS and MultiScreen vacuum manifolds, as well as MultiScreen Solvinert filter plates.Applications -Vacuum Filtration of Multiwell Filter Plates, Automated Liquid Handling
  • Catalogue Number
  • MSVMHTS06
  • Material Size
  • 1
  • Trade Name
  • MultiScreen
MERSSTX01 Replacement Electrodes, 1 pair 251 
Add to Cart
  • Background Information
  • The Millicell® ERS-2 (Electrical Resistance System) reliably measures membrane potential and resistance of epithelial cells in culture. This device qualitatively measures cell monolayer health and quantitatively measures cell confluence. A silver/silver chloride (Ag/AgCl) pellet on each electrode tip measures voltage. Due to the small size of the electrodes, you can easily measure transepithelial voltage and the resistance of cells grown on microporous membranes. Accessories include a replacement (fixed) electrode set, adjustable electrode set and a specialized electrode set for use with Millicell®-96 cell culture insert plates.Features & Benefits: - Portable instrument that fits into laminar flow hoods - Measurements do not compromise sterility or damage cells on the membrane - Widely cited and recommended in epithelial cell culture protocols Applications: - Measurement of Transepithelial Electrical Resistance (TEER), Cell Monolayer Health Assessment, Quantitative Measurement of Confluence
  • Catalogue Number
  • MERSSTX01
  • Material Size
  • 1
  • Stem Cell Type
  • Mouse Embryonic Stem CellsHuman Embryonic Stem CellsMesenchymal Stem CellsNeural Stem CellsHematopoietic Stem CellsEpithelial CellsPancreatic Stem CellsCardiac Stem CellsInduced Pluripotent Stem Cells
  • Trade Name
  • Millicell
MK40-285 Handheld Magnetic Separator Block for 96 Well Flat Bottom Plates or 96 Well Conical Well Plates 598 
Add to Cart
  • Catalogue Number
  • 40-285
  • Key Applications
  • Multiplexing
  • Material Size
  • 1
  • Overview
  • The Handheld Magnetic Separator Block offers a low cost option for biomagnetic separation. Magnets are positioned around the bottom of the well to pull the beads to the side of the well. The top magnetic frame is white polycarbonate, with a corrosion resistant steel plate underneath, all mounted to a polypropylene base. An adjustable clip system holds a wide variety of microplates to the separator and an O-Ring on the base plate facilitates gripping.
  • Trade Name
  • MILLIPLEX
WP6110060 Chemical Duty Pump, 100 V/50–60 Hz 726 
Add to Cart
  • Catalogue Number
  • WP6110060
  • Material Size
  • 1
  • Overview
  • OverviewThe High Output Pump features a piston-driven design for greater power.The Chemical Duty Pump has a chemically-resistant head and diaphragm for use with corrosive chemicals and solvents.Both pumps come with 70 cm of 1/4" tubing and a Millex FA50 filter for in-line moisture protection. Both are UL listed and CE marked.The High Output and Chemical Duty pumps can support high flow rates to decrease process filtration time. The High Output Pump features a piston-driven design for greater power. The Chemical Duty Pump has a chemically-resistant head and diaphragm for use with corrosive chemicals and solvents. Both pumps come with 70 cm of 1/4 in. tubing and a Millex®-FA50 filter for in-line moisture protection. Both are UL-listed and CE-marked.Features & BenefitsHigh flow rates decrease filtration process time Optional chemical-resistant internal components for compatibility with corrosive vapors Portable design allows for easy sharing between workstations ApplicationsVacuum Source for Filter Holders, Manifolds, and Devices, including Samplicity® Filtration System, SNAP i.d.® 2.0 System, Multiscreen®HTS Filtration Manifold, and Stericup® FiltersFor more information visit the EMDMillipore Vacuum Hardware site.
WP6122050 Chemical Duty Pump, 220 V/50 Hz 726 
Add to Cart
  • Catalogue Number
  • WP6122050
  • Material Size
  • 1
  • Overview
  • OverviewThe High Output Pump features a piston-driven design for greater power.The Chemical Duty Pump has a chemically-resistant head and diaphragm for use with corrosive chemicals and solvents.Both pumps come with 70 cm of 1/4" tubing and a Millex FA50 filter for in-line moisture protection. Both are UL listed and CE marked.The High Output and Chemical Duty pumps can support high flow rates to decrease process filtration time. The High Output Pump features a piston-driven design for greater power. The Chemical Duty Pump has a chemically-resistant head and diaphragm for use with corrosive chemicals and solvents. Both pumps come with 70 cm of 1/4 in. tubing and a Millex®-FA50 filter for in-line moisture protection. Both are UL-listed and CE-marked.Features & BenefitsHigh flow rates decrease filtration process time Optional chemical-resistant internal components for compatibility with corrosive vapors Portable design allows for easy sharing between workstations ApplicationsVacuum Source for Filter Holders, Manifolds, and Devices, including Samplicity® Filtration System, SNAP i.d.® 2.0 System, Multiscreen®HTS Filtration Manifold, and Stericup® FiltersFor more information visit the EMDMillipore Vacuum Hardware site.
WP6111560 Chemical Duty Pump, 115 V/60 Hz 762 
Add to Cart
  • Catalogue Number
  • WP6111560
  • Material Size
  • 1
  • Overview
  • OverviewThe High Output Pump features a piston-driven design for greater power.The Chemical Duty Pump has a chemically-resistant head and diaphragm for use with corrosive chemicals and solvents.Both pumps come with 70 cm of 1/4" tubing and a Millex FA50 filter for in-line moisture protection. Both are UL listed and CE marked.The High Output and Chemical Duty pumps can support high flow rates to decrease process filtration time. The High Output Pump features a piston-driven design for greater power. The Chemical Duty Pump has a chemically-resistant head and diaphragm for use with corrosive chemicals and solvents. Both pumps come with 70 cm of 1/4 in. tubing and a Millex®-FA50 filter for in-line moisture protection. Both are UL-listed and CE-marked.Features & BenefitsHigh flow rates decrease filtration process time Optional chemical-resistant internal components for compatibility with corrosive vapors Portable design allows for easy sharing between workstations ApplicationsVacuum Source for Filter Holders, Manifolds, and Devices, including Samplicity® Filtration System, SNAP i.d.® 2.0 System, Multiscreen®HTS Filtration Manifold, and Stericup® FiltersFor more information visit the EMDMillipore Vacuum Hardware site.
PSRP004R5 Millicell-96 Cell Culture Insert Plate, polyethylene terephthalate, 1.0 µm 1308 
Add to Cart
  • Automation Compatible
  • Yes
  • Background Information
  • Millicell cell culture insert plates are a patented device designed to support cell growth and differentiation of endothelial and epithelial cell lines, including CaCo-2. The Millicell device is available with a 0.4 µm PCF and a variety of PET membrane pore sizes. The plate is designed for maximum user convenience and incorporates features such as apical assist for easier pipetting and basolateral access. To reduce the risk of monolayer contamination, the membrane plates have feet to elevate the plate above the work surface when disassembled from the feeder tray. Tear drop-shaped receiver wells eliminate air bubbles as plates are assembled.Millicell plate are optimized to grow and sustain high integrity cell monolayers. Cells grown on Millicell plate membranes grow better than on plastic because the cells are nourished from both the apical and basolateral sides. Cell growth and function more closely mimic in vivo. Millicell plates are designed for analysis as well as cell growth and can be used manually or with automated cell seeding, feeding and washing systemsWith this complete system, you can grow, feed, and analyze cells in one membrane-bottom plate. The plate can be used with either a single-well or a multi-well feeding tray. At the time of transport analysis, the plate is simply transferred to a multi-well transport tray for analysis. This streamlined design enhances functionality with: - Seed-and-feed systems - Automated liquid handling systems and span pipettes - Basolateral and apical access to cells - Transepithelial electrical resistance (TEER) measurement systems
  • Catalogue Number
  • PSRP004R5
  • Chemistry
  • Polyethylene Terephthalate (PET)
  • Components
  • 96-well cell culture plate, single-well feeder tray, lid
  • Device Configuration
  • 96-well plate
  • Device Material
  • Polystyrene
  • Filter Code
  • PET
  • Filter Diameter (⌀)
  • 0.4 mm
  • Filtration Area
  • 0.11 cm²
  • Height
  • 26.2 mm
  • Key Applications
  • Cell AttachmentCell CultureCell DifferentiationImmunocytochemistry
  • Length
  • 128 mm
  • Material Package
  • Bulk packed
  • Material Size
  • 5
  • Maximum Operating Temperature
  • 50 °C
  • Number of Wells
  • 96
  • Pore Size
  • 1.0 µm
  • Stem Cell Type
  • Mouse Embryonic Stem CellsHuman Embryonic Stem CellsMesenchymal Stem CellsNeural Stem CellsHematopoietic Stem CellsEpithelial CellsPancreatic Stem CellsCardiac Stem CellsInduced Pluripotent Stem Cells
  • Sterility
  • Sterile
  • Trade Name
  • Millicell
  • Width
  • 84.8 mm